Water heating and drying using solar energy and air-con wastage /

The waste heat from the air-conditioner will usually be released in the atmosphere which in turn contributes to the global warming. In every kW of electricity, which is used in air-conditioning, about 4 kW of the thermal energy is dumped into the environment at about 80o C causing the global warming...

全面介绍

Saved in:
书目详细资料
主要作者: Sharieff, Zohra Begum Hameed
格式: Thesis
语言:English
出版: Gombak, Selangor : Kulliyyah of Engineering, International Islamic University Malaysia, 2016
主题:
在线阅读:http://studentrepo.iium.edu.my/handle/123456789/5330
标签: 添加标签
没有标签, 成为第一个标记此记录!
实物特征
总结:The waste heat from the air-conditioner will usually be released in the atmosphere which in turn contributes to the global warming. In every kW of electricity, which is used in air-conditioning, about 4 kW of the thermal energy is dumped into the environment at about 80o C causing the global warming. In this thesis, experiments are carried out on water heating and drying using a Solar 3 in 1 system. The values were taken for an interval of every 10 minutes and the heat variation inside the tank and the drying weight of the cloth were measured. The drying is carried out by using the waste heat from the condenser. A mathematical model has been formulated for the system and the simulation is carried out with MATLAB. A series of experiments were conducted under the meteorological conditions of Malaysia to compare the results of the experimental and predicted values. The values were in agreement with the predicted and experimental results.
实物描述:xv, 75 leaves : ill. ; 30cm.
参考书目:Includes bibliographical references (leaves 64-67).