Water heating and drying using solar energy and air-con wastage /

The waste heat from the air-conditioner will usually be released in the atmosphere which in turn contributes to the global warming. In every kW of electricity, which is used in air-conditioning, about 4 kW of the thermal energy is dumped into the environment at about 80o C causing the global warming...

Full description

Saved in:
Bibliographic Details
Main Author: Sharieff, Zohra Begum Hameed
Format: Thesis
Language:English
Published: Gombak, Selangor : Kulliyyah of Engineering, International Islamic University Malaysia, 2016
Subjects:
Online Access:http://studentrepo.iium.edu.my/handle/123456789/5330
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 022770000a22002770004500
008 160907t2016 my a g m 000 0 eng d
040 |a UIAM  |b eng 
041 |a eng 
043 |a a-my--- 
050 0 0 |a TJ810 
100 1 |a Sharieff, Zohra Begum Hameed 
245 1 |a Water heating and drying using solar energy and air-con wastage /  |c by Zohra Begum Hameed Sharieff 
260 |a Gombak, Selangor :  |b Kulliyyah of Engineering, International Islamic University Malaysia,  |c 2016 
300 |a xv, 75 leaves :  |b ill. ;  |c 30cm. 
502 |a Thesis (MSME)--International Islamic University Malaysia, 2016. 
504 |a Includes bibliographical references (leaves 64-67). 
520 |a The waste heat from the air-conditioner will usually be released in the atmosphere which in turn contributes to the global warming. In every kW of electricity, which is used in air-conditioning, about 4 kW of the thermal energy is dumped into the environment at about 80o C causing the global warming. In this thesis, experiments are carried out on water heating and drying using a Solar 3 in 1 system. The values were taken for an interval of every 10 minutes and the heat variation inside the tank and the drying weight of the cloth were measured. The drying is carried out by using the waste heat from the condenser. A mathematical model has been formulated for the system and the simulation is carried out with MATLAB. A series of experiments were conducted under the meteorological conditions of Malaysia to compare the results of the experimental and predicted values. The values were in agreement with the predicted and experimental results. 
596 |a 1 
655 7 |a Theses, IIUM local 
690 |a Dissertations, Academic  |x Department of Mechanical Engineering  |z IIUM 
710 2 |a International Islamic University Malaysia.  |b Department of Mechanical Engineering 
856 4 |u http://studentrepo.iium.edu.my/handle/123456789/5330 
900 |a sbh-ls 
999 |c 436431  |d 468174 
952 |0 0  |6 T TJ 000810 S531W 2016  |7 0  |8 THESES  |9 761269  |a IIUM  |b IIUM  |c MULTIMEDIA  |g 0.00  |o t TJ 810 S531W 2016  |p 11100350445  |r 2017-10-20  |t 1  |v 0.00  |y THESIS 
952 |0 0  |6 TS CDF TJ 810 S531W 2016  |7 0  |8 THESES  |9 854913  |a IIUM  |b IIUM  |c MULTIMEDIA  |g 0.00  |o ts cdf TJ 810 S531W 2016  |p 11100350446  |r 2017-10-26  |t 1  |v 0.00  |y THESISDIG