Stepped impedance interdigital capacitive RF sensor for continous blood glucose monitoring /

Diabetes is a growing chronic disease that affects millions of people in the world. Regular monitoring of blood glucose levels in patients is necessary to keep the disease under control. Current methods of blood glucose monitoring devices are typically invasive, finger pricking to extract blood, cau...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Farhan Affendi Mohamad Yunos (Author)
Format: Thesis
Language:English
Published: Kuala Lumpur : Kulliyyah of Engineering,International Islamic University Malaysia, 2021
Subjects:
Online Access:http://studentrepo.iium.edu.my/handle/123456789/11010
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 043430000a22004210004500
008 220422s2021 my a f m 000 0 eng d
040 |a UIAM  |b eng  |e rda 
041 |a eng 
043 |a a-my---  
050 0 0 |a RC660.A2 
100 0 |a Muhammad Farhan Affendi Mohamad Yunos  |9 7966  |e author 
245 1 0 |a Stepped impedance interdigital capacitive RF sensor for continous blood glucose monitoring /  |c by Muhammad Farhan Affendi Bin Mohamad Yunos 
264 1 |a Kuala Lumpur :  |b Kulliyyah of Engineering,International Islamic University Malaysia,  |c 2021 
300 |a xvi, 88 leaves :  |b colour illustrations ;  |c 30 cm. 
336 |2 rdacontent  |a text 
337 |2 rdamedia  |a unmediated 
337 |2 rdamedia  |a computer 
338 |2 rdacarrier  |a volume 
338 |2 rdacarrier  |a online resource 
347 |2 rdaft  |a text file  |b PDF 
500 |a Abstracts in English and Arabic. 
500 |a "A thesis submitted in fulfilment of the requirement for the degree of Master of Science (Electronics Engineering)." --On title page. 
502 |a Thesis (MSEE)--International Islamic University Malaysia, 2021. 
504 |a Includes bibliographical references (leaves 83-87). 
520 |a Diabetes is a growing chronic disease that affects millions of people in the world. Regular monitoring of blood glucose levels in patients is necessary to keep the disease under control. Current methods of blood glucose monitoring devices are typically invasive, finger pricking to extract blood, causing discomfort to the patients. Non-invasive glucose monitoring is a possible game-changer for diabetic patients as it reduces discomfort and provides continuous monitoring. Interdigital sensors have been implemented in various applications such as chemical and biological sensing and have shown good sensitivities. This work describes the design and fabrication of an interdigital sensor (IDT) that has the potential of estimating blood glucose levels using capacitive measurements. The interdigital sensor produces an electric field that penetrates the material under test and detects the changes in the dielectric constant of the material. When used on top of the skin, it can be used to detect permittivity changes in the skin and the blood vessels underneath it. The IDT sensor was first designed using theoretical equations and later was optimized by using CST Microwave Studio®. Upon completion of simulations, the sensor was fabricated using copper-clad FR4 boards. The fabricated sensors were measured using an RF analyzer. This stepped impedance component was added to the sensor so that it has low noise and high Q-factor. In addition, a microfluidic device structure that imitates the real vessel structure on the human hand was fabricated to measure the change in permittivity for different glucose concentrations. During experiments, the IDT sensor was tested with varying glucose concentrations (0 to 240 mg/dL). The S11 frequency response was measured and the relationship between S11 resonant frequency and glucose concentration was plotted. It was observed that as the glucose concentration increases, the frequency values also increases. The linear relationship between frequency and glucose concentration was also plotted the sensitivity (slope) and the limit of detection (LOD) of the sensor. The result shows that the sensitivity of the biosensor is 264.2 kHz/mgdL-1, and LOD was calculated to be at 29.89 mg/dL. This indicates that the IDT sensor has good potential to be a non-invasive sensor for glucose monitoring. 
650 0 |a Blood Glucose  |x analysis  |9 11660 
650 0 |a Blood glucose monitoring  |9 11661 
650 0 |a Biosensors  |9 11662 
655 |a Theses, IIUM local 
690 |a Dissertations, Academic  |x Department of Electrical and Computer Engineering  |z IIUM  |9 4446 
700 0 |a Anis Nurashikin Nordin  |e degree supervisor  |9 6562 
700 1 |a  Sheroz Khan  |e degree supervisor  |9 7967 
710 2 |a International Islamic University Malaysia.  |b Department of Electrical and Computer Engineering  |9 4449 
856 4 |u http://studentrepo.iium.edu.my/handle/123456789/11010 
900 |a sz-asbh 
942 |2 lcc  |c THESIS  |n 0 
999 |c 502876  |d 534293 
952 |0 0  |1 0  |2 lcc  |4 0  |6 T R C660 A2 M00952S 02021  |7 3  |8 IIUMTHESIS  |9 982082  |a IIUM  |b IIUM  |c THESIS  |d 2022-08-11  |g 0.00  |o t RC 660 A2 M952S 2021  |p 11100437185  |r 1900-01-02  |t 1  |v 0.00  |y THESIS