Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa

Titanium and its alloys have widely been used as metallic implants because of their good biocompatibility and high corrosion resistance. However, they exhibit no bioactive properties and fail to bind to bone tissue. In order to make the titanium implants bioactive, hydroxyapatite (HAp) has been coat...

Full description

Saved in:
Bibliographic Details
Main Author: Che Isa, Nik Norziehana
Format: Thesis
Language:English
Published: 2013
Online Access:https://ir.uitm.edu.my/id/eprint/18415/3/18415.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.18415
record_format uketd_dc
spelling my-uitm-ir.184152024-05-31T06:45:35Z Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa 2013-05 Che Isa, Nik Norziehana Titanium and its alloys have widely been used as metallic implants because of their good biocompatibility and high corrosion resistance. However, they exhibit no bioactive properties and fail to bind to bone tissue. In order to make the titanium implants bioactive, hydroxyapatite (HAp) has been coated onto titanium surface. In this study, HAp coatings were successfully prepared on titanium substrates by electrodeposition technique using aqueous solution containing CaCb + NH4H2PO4 with Ca/P ratio equal to 1.67. The effects of varying deposition conditions and solutions such as applied potential, deposition time, deposition solution concentration and the addition of chitosan into deposition solution on the electrodeposition process as well as the formation of HAp coatings were investigated. The obtained deposited HAp samples were characterized using FESEM, EDAX, XRD, FTIR, immersion in SBF solution and Scotch® tape test. The deposition conditions and solutions have strongly affected the formation of HAp coatings. The best HAp coating was produced by applying a constant potential o f - 1.5 V vs Ag/AgCl using 0.167 M CaC^ + 0.1 M NH4H2PO4 solution at 80 °C for 30 min. The addition of 5 volume percent of chitosan into the deposition solution has improved the adhesion of HAp coatings on the Ti surface. It was found that the prepared HAp coatings are bioactive as shown by the change of surface morphology after immersion in SBF solution for a few days. The HAp material can also be deposited on different types of Ti substrates (i.e.: Ti mesh and NiTi alloy) using the electrodeposition technique. It was also proven that coated HAp onto Ti substrates gave better physicochemical properties of Ti implants. 2013-05 Thesis https://ir.uitm.edu.my/id/eprint/18415/ https://ir.uitm.edu.my/id/eprint/18415/3/18415.pdf text en public mphil masters Universiti Teknologi MARA Faculty of Applied Sciences
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
description Titanium and its alloys have widely been used as metallic implants because of their good biocompatibility and high corrosion resistance. However, they exhibit no bioactive properties and fail to bind to bone tissue. In order to make the titanium implants bioactive, hydroxyapatite (HAp) has been coated onto titanium surface. In this study, HAp coatings were successfully prepared on titanium substrates by electrodeposition technique using aqueous solution containing CaCb + NH4H2PO4 with Ca/P ratio equal to 1.67. The effects of varying deposition conditions and solutions such as applied potential, deposition time, deposition solution concentration and the addition of chitosan into deposition solution on the electrodeposition process as well as the formation of HAp coatings were investigated. The obtained deposited HAp samples were characterized using FESEM, EDAX, XRD, FTIR, immersion in SBF solution and Scotch® tape test. The deposition conditions and solutions have strongly affected the formation of HAp coatings. The best HAp coating was produced by applying a constant potential o f - 1.5 V vs Ag/AgCl using 0.167 M CaC^ + 0.1 M NH4H2PO4 solution at 80 °C for 30 min. The addition of 5 volume percent of chitosan into the deposition solution has improved the adhesion of HAp coatings on the Ti surface. It was found that the prepared HAp coatings are bioactive as shown by the change of surface morphology after immersion in SBF solution for a few days. The HAp material can also be deposited on different types of Ti substrates (i.e.: Ti mesh and NiTi alloy) using the electrodeposition technique. It was also proven that coated HAp onto Ti substrates gave better physicochemical properties of Ti implants.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Che Isa, Nik Norziehana
spellingShingle Che Isa, Nik Norziehana
Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa
author_facet Che Isa, Nik Norziehana
author_sort Che Isa, Nik Norziehana
title Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa
title_short Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa
title_full Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa
title_fullStr Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa
title_full_unstemmed Physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / Nik Norziehana Che Isa
title_sort physicochemical and bioactivity properties of hydroxy apatite coatings electrodeposited onto titanium substrates / nik norziehana che isa
granting_institution Universiti Teknologi MARA
granting_department Faculty of Applied Sciences
publishDate 2013
url https://ir.uitm.edu.my/id/eprint/18415/3/18415.pdf
_version_ 1804889573636964352