Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan

This project involved in the study of notched strength reduction and determination of damage zone, aₒ, of E-glass, Kevlar and Carbon Fiber/Epoxy composite laminates. The specimen configuration used for this project was 101.6 mmx 101.6 mm with 30 mm diameter central hole and was subjected to bi-axial...

Full description

Saved in:
Bibliographic Details
Main Author: Norizan, Norhazwan
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/21302/1/TD_NORHAZWAN%20NORIZAN%20EM%2005_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.21302
record_format uketd_dc
spelling my-uitm-ir.213022018-10-02T07:42:58Z Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan 2005 Norizan, Norhazwan Polymers and polymer manufacture This project involved in the study of notched strength reduction and determination of damage zone, aₒ, of E-glass, Kevlar and Carbon Fiber/Epoxy composite laminates. The specimen configuration used for this project was 101.6 mmx 101.6 mm with 30 mm diameter central hole and was subjected to bi-axial loading condition using a special grip and fixture. The damage zones, aₒ, was determined experimentally using optical microscope. Using the values aₒ, the notched strength of the laminates were then determined using both Average Stress Criterion (ASC) and the Fracture Mechanics Criterion (FMC). These calculated values of notched strengths were then compared with that determined through experimentation. In this project, the results indicated that the notched strengths of the glass fiber/epoxy using the Average Stress Criterion and Fracture Mechanics Criterion are comparable. However, the notched strength predicted by the Fracture Mechanics Criterion was about 50% indifference with the Average Stress Criterion for Kevlar and carbon fiber/epoxy. This might be due to the determination of fracture toughness, Kc, using isotropic solution may not be suitable for these materials. Experimental values of the notched strengths of the laminates under bi-axial loading in the experiments cannot be acceptable due to the problems occurred at the grip. Further improvements are needed to overcome the grip problems or new fixture should be designed and constructed in order to obtain better results in the future. 2005 Thesis https://ir.uitm.edu.my/id/eprint/21302/ https://ir.uitm.edu.my/id/eprint/21302/1/TD_NORHAZWAN%20NORIZAN%20EM%2005_5.pdf text en public degree Universiti Teknologi MARA Faculty of Mechanical Engineering
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
topic Polymers and polymer manufacture
spellingShingle Polymers and polymer manufacture
Norizan, Norhazwan
Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
description This project involved in the study of notched strength reduction and determination of damage zone, aₒ, of E-glass, Kevlar and Carbon Fiber/Epoxy composite laminates. The specimen configuration used for this project was 101.6 mmx 101.6 mm with 30 mm diameter central hole and was subjected to bi-axial loading condition using a special grip and fixture. The damage zones, aₒ, was determined experimentally using optical microscope. Using the values aₒ, the notched strength of the laminates were then determined using both Average Stress Criterion (ASC) and the Fracture Mechanics Criterion (FMC). These calculated values of notched strengths were then compared with that determined through experimentation. In this project, the results indicated that the notched strengths of the glass fiber/epoxy using the Average Stress Criterion and Fracture Mechanics Criterion are comparable. However, the notched strength predicted by the Fracture Mechanics Criterion was about 50% indifference with the Average Stress Criterion for Kevlar and carbon fiber/epoxy. This might be due to the determination of fracture toughness, Kc, using isotropic solution may not be suitable for these materials. Experimental values of the notched strengths of the laminates under bi-axial loading in the experiments cannot be acceptable due to the problems occurred at the grip. Further improvements are needed to overcome the grip problems or new fixture should be designed and constructed in order to obtain better results in the future.
format Thesis
qualification_level Bachelor degree
author Norizan, Norhazwan
author_facet Norizan, Norhazwan
author_sort Norizan, Norhazwan
title Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_short Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_full Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_fullStr Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_full_unstemmed Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_sort notched strength of fiber-reinforced polymer (frp) / norhazwan norizan
granting_institution Universiti Teknologi MARA
granting_department Faculty of Mechanical Engineering
publishDate 2005
url https://ir.uitm.edu.my/id/eprint/21302/1/TD_NORHAZWAN%20NORIZAN%20EM%2005_5.pdf