Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar

The main indication for a shoulder replacement is pain relief. Occasionally, shoulder replacement surgery is needed for certain fractures around the shoulder, but most shoulder replacements occur after years of wear, tear and dislocation of the glenoid joint on the shoulder. The humeral head rarely...

Full description

Saved in:
Bibliographic Details
Main Author: Abu Bakar, Rushafinas
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/68437/1/68437.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.68437
record_format uketd_dc
spelling my-uitm-ir.684372022-10-13T06:42:45Z Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar 2010 Abu Bakar, Rushafinas The Articulations, Joints Surgery by region, system, or organ The main indication for a shoulder replacement is pain relief. Occasionally, shoulder replacement surgery is needed for certain fractures around the shoulder, but most shoulder replacements occur after years of wear, tear and dislocation of the glenoid joint on the shoulder. The humeral head rarely can dislocate from the glenoid component because of the different mismatch sizes of prosthesis stem with the patient. The aim of this study is to see the implication of the Asian proximal humerus geometric to the previous shoulder prosthesis design and construct a possible size of shoulder prosthesis stem for Asian. The scope of this study is to perform the Finite Element Analysis on Asian and Caucasian shoulder with the implemented implant. The dimension of shoulder was based on previous Anthropometric measurement data. The shoulder prosthesis used in this study is a Zimmer Anatomical Shoulder Systems. It's the third generation of stem designs. The material was used is Titanium Alloy Ti-6A1-4V. The loading that has to be considered is muscle force at average body weight. The distal end of the humerus is fixed. Results, shows that the stress distribution of shoulder with implemented stem. Analysis of this shoulder is sufficient to study the stress behavior of the TSR on humerus bone. The stresses for the TSR on humerus bone were reduced at modified design size compared to existing design size. 2010 Thesis https://ir.uitm.edu.my/id/eprint/68437/ https://ir.uitm.edu.my/id/eprint/68437/1/68437.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Mechanical Engineering Abdullah, Abdul Halim
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Abdullah, Abdul Halim
topic The Articulations
Joints
The Articulations
Joints
spellingShingle The Articulations
Joints
The Articulations
Joints
Abu Bakar, Rushafinas
Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
description The main indication for a shoulder replacement is pain relief. Occasionally, shoulder replacement surgery is needed for certain fractures around the shoulder, but most shoulder replacements occur after years of wear, tear and dislocation of the glenoid joint on the shoulder. The humeral head rarely can dislocate from the glenoid component because of the different mismatch sizes of prosthesis stem with the patient. The aim of this study is to see the implication of the Asian proximal humerus geometric to the previous shoulder prosthesis design and construct a possible size of shoulder prosthesis stem for Asian. The scope of this study is to perform the Finite Element Analysis on Asian and Caucasian shoulder with the implemented implant. The dimension of shoulder was based on previous Anthropometric measurement data. The shoulder prosthesis used in this study is a Zimmer Anatomical Shoulder Systems. It's the third generation of stem designs. The material was used is Titanium Alloy Ti-6A1-4V. The loading that has to be considered is muscle force at average body weight. The distal end of the humerus is fixed. Results, shows that the stress distribution of shoulder with implemented stem. Analysis of this shoulder is sufficient to study the stress behavior of the TSR on humerus bone. The stresses for the TSR on humerus bone were reduced at modified design size compared to existing design size.
format Thesis
qualification_level Bachelor degree
author Abu Bakar, Rushafinas
author_facet Abu Bakar, Rushafinas
author_sort Abu Bakar, Rushafinas
title Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_short Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_full Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_fullStr Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_full_unstemmed Shoulder prosthesis stem design based on anthropometric measurement data for Asian population / Rushafinas Abu Bakar
title_sort shoulder prosthesis stem design based on anthropometric measurement data for asian population / rushafinas abu bakar
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Mechanical Engineering
publishDate 2010
url https://ir.uitm.edu.my/id/eprint/68437/1/68437.pdf
_version_ 1783735778876063744