The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari
Continuous demand in power transmission network caused by reactive power has been highlighted as the main factor in voltage depreciation and also increase of total transmission loss. Past studies have reported several possible techniques such as optimal reactive power dispatch, optimal capacitor pla...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2010
|
Online Access: | https://ir.uitm.edu.my/id/eprint/84876/1/84876.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uitm-ir.84876 |
---|---|
record_format |
uketd_dc |
spelling |
my-uitm-ir.848762024-04-18T08:12:02Z The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari 2010 Md Hodari, Melor Continuous demand in power transmission network caused by reactive power has been highlighted as the main factor in voltage depreciation and also increase of total transmission loss. Past studies have reported several possible techniques such as optimal reactive power dispatch, optimal capacitor placement; transformer tap setting and static VAR compensator are solutions for reducing voltage collapse occurrences. This paper presents Ant Colony Optimization (ACO) technique to improve voltage stability condition along with transmission loss and voltage profile monitoring using STATCOM. The purpose is to search for a solution for the best parameters of ACO that will improve the voltages and also to reduce the power losses in an electric power system. The proposed technique was tested using the standard IEEE 30-bus system and the capability of developed ACO in solving continuous optimization problems has been revealed as the added value in the algorithm. 2010 Thesis https://ir.uitm.edu.my/id/eprint/84876/ https://ir.uitm.edu.my/id/eprint/84876/1/84876.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Nik Ismail, Nik Fasdi |
institution |
Universiti Teknologi MARA |
collection |
UiTM Institutional Repository |
language |
English |
advisor |
Nik Ismail, Nik Fasdi |
description |
Continuous demand in power transmission network caused by reactive power has been highlighted as the main factor in voltage depreciation and also increase of total transmission loss. Past studies have reported several possible techniques such as optimal reactive power dispatch, optimal capacitor placement; transformer tap setting and static VAR compensator are solutions for reducing voltage collapse occurrences. This paper presents Ant Colony Optimization (ACO) technique to improve voltage stability condition along with transmission loss and voltage profile monitoring using STATCOM. The purpose is to search for a solution for the best parameters of ACO that will improve the voltages and also to reduce the power losses in an electric power system. The proposed technique was tested using the standard IEEE 30-bus system and the capability of developed ACO in solving continuous optimization problems has been revealed as the added value in the algorithm. |
format |
Thesis |
qualification_level |
Bachelor degree |
author |
Md Hodari, Melor |
spellingShingle |
Md Hodari, Melor The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari |
author_facet |
Md Hodari, Melor |
author_sort |
Md Hodari, Melor |
title |
The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari |
title_short |
The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari |
title_full |
The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari |
title_fullStr |
The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari |
title_full_unstemmed |
The study of ant colony optimization (ACO) parameters for STATCOM optimization / Melor Md Hodari |
title_sort |
study of ant colony optimization (aco) parameters for statcom optimization / melor md hodari |
granting_institution |
Universiti Teknologi MARA (UiTM) |
granting_department |
Faculty of Electrical Engineering |
publishDate |
2010 |
url |
https://ir.uitm.edu.my/id/eprint/84876/1/84876.pdf |
_version_ |
1804889740222136320 |