The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron

In this project, the 100kVA three phase transformer core model have been investigated and analyzed for its losses and flux distribution using different thickness lamination of the core built with grain-oriented silicon iron (3.1% SiFe), grade M4. The transformer core has been assembled with 60o T-jo...

Full description

Saved in:
Bibliographic Details
Main Author: Nor Ashbahani, Mohamad Kajaan
Format: Thesis
Language:English
Subjects:
Online Access:http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/1/Page%201-24.pdf
http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/2/Full%20text.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-unimap-31923
record_format uketd_dc
spelling my-unimap-319232014-02-14T01:53:09Z The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron Nor Ashbahani, Mohamad Kajaan In this project, the 100kVA three phase transformer core model have been investigated and analyzed for its losses and flux distribution using different thickness lamination of the core built with grain-oriented silicon iron (3.1% SiFe), grade M4. The transformer core has been assembled with 60o T-joint, mitred overlap corner joints using two different thickness of transformer core material, which is 0.23mm and 0.27mm. This research was done with 3D FEM software approaches and experimental methods. From 3D Finite Element Method (FEM), the total magnetic flux density when transformer core assembled with different lamination thickness is obtained. Based on FEM, thinner lamination steel shows better magnetic flux density compared to using thicker lamination steel by percentage of 2.9%. Experimental has been carried out using no load test with arrays of search coil that has been placed to the lamination of the transformer core in order to measure localized and normal flux density distribution and also its odd harmonic content. Localized power loss distribution at the transformer core also done by using thermistor method. Building factor for the transformer core that used thinner lamination steel is better by 2.5% compared to the thicker lamination steel. The experimental results show that when the core flux density increased from 1.0T to 1.8T, the flux distribution in the lamination will show interesting trend at both T-joint and corner joint. The performance at the corner joint shows better result, where high loss will tends to occur more at the T-joint area. The highest losses and flux distribution will occur during 1.8T and the lowest is during 1.0T respectively for both lamination thicknesses. Losses mostly high at the intersection of the joint and will gradually decrease as it travel away from the joint area as indicated by 3D FEM software. Overall, the transformer core that assembled with 0.23mm lamination steel will generate more efficient distribution transformer since it produce lower losses and better flux distribution compared to 0.27mm lamination steel. Therefore, the results obtained by experiment comply with the simulation result obtained by FEM software. In term of economic aspects, large amount of money can be saved when the distribution transformer core been replaced with thinner lamination steel. Universiti Malaysia Perlis (UniMAP) 2012 Thesis en http://dspace.unimap.edu.my:80/dspace/handle/123456789/31923 http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/1/Page%201-24.pdf 355224b833659b0bf2048e5b79ee2d04 http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/2/Full%20text.pdf 0cdbf3b8c3b44602efa0acc45c3144a3 http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/3/license.txt 8a4605be74aa9ea9d79846c1fba20a33 Transformers Flux distribution Power loss Transformer core Grain-oriented silicon iron School of Electrical System Engineering
institution Universiti Malaysia Perlis
collection UniMAP Institutional Repository
language English
topic Transformers
Flux distribution
Power loss
Transformer core
Grain-oriented silicon iron
spellingShingle Transformers
Flux distribution
Power loss
Transformer core
Grain-oriented silicon iron
Nor Ashbahani, Mohamad Kajaan
The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
description In this project, the 100kVA three phase transformer core model have been investigated and analyzed for its losses and flux distribution using different thickness lamination of the core built with grain-oriented silicon iron (3.1% SiFe), grade M4. The transformer core has been assembled with 60o T-joint, mitred overlap corner joints using two different thickness of transformer core material, which is 0.23mm and 0.27mm. This research was done with 3D FEM software approaches and experimental methods. From 3D Finite Element Method (FEM), the total magnetic flux density when transformer core assembled with different lamination thickness is obtained. Based on FEM, thinner lamination steel shows better magnetic flux density compared to using thicker lamination steel by percentage of 2.9%. Experimental has been carried out using no load test with arrays of search coil that has been placed to the lamination of the transformer core in order to measure localized and normal flux density distribution and also its odd harmonic content. Localized power loss distribution at the transformer core also done by using thermistor method. Building factor for the transformer core that used thinner lamination steel is better by 2.5% compared to the thicker lamination steel. The experimental results show that when the core flux density increased from 1.0T to 1.8T, the flux distribution in the lamination will show interesting trend at both T-joint and corner joint. The performance at the corner joint shows better result, where high loss will tends to occur more at the T-joint area. The highest losses and flux distribution will occur during 1.8T and the lowest is during 1.0T respectively for both lamination thicknesses. Losses mostly high at the intersection of the joint and will gradually decrease as it travel away from the joint area as indicated by 3D FEM software. Overall, the transformer core that assembled with 0.23mm lamination steel will generate more efficient distribution transformer since it produce lower losses and better flux distribution compared to 0.27mm lamination steel. Therefore, the results obtained by experiment comply with the simulation result obtained by FEM software. In term of economic aspects, large amount of money can be saved when the distribution transformer core been replaced with thinner lamination steel.
format Thesis
author Nor Ashbahani, Mohamad Kajaan
author_facet Nor Ashbahani, Mohamad Kajaan
author_sort Nor Ashbahani, Mohamad Kajaan
title The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
title_short The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
title_full The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
title_fullStr The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
title_full_unstemmed The effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
title_sort effect of lamination thickness of transformer core on the flux and power loss distribution using grain-oriented 3.1% silicon iron
granting_institution Universiti Malaysia Perlis (UniMAP)
granting_department School of Electrical System Engineering
url http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/1/Page%201-24.pdf
http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/31923/2/Full%20text.pdf
_version_ 1747836796393226240