Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit

Anodic aluminum oxide (AAO) films have been investigated and used in numerous products for more than 50 years. The morphologies of the AAO films can be classified into barrier-type and porous-type. Barrier-type films consist of compact amorphous alumina, while porous-type films comprise of a thin...

Full description

Saved in:
Bibliographic Details
Main Author: Alaba Oladeji, Araoyinbo
Format: Thesis
Language:English
Subjects:
Online Access:http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/1/P.1-24.pdf
http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/2/Full%20Text.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-unimap-42883
record_format uketd_dc
institution Universiti Malaysia Perlis
collection UniMAP Institutional Repository
language English
advisor Dr. Mohd Nazree Derman
topic Electrochemical anodization
Aluminum
Anodic aluminum oxide (AAO)
Aanodization
AAO films
spellingShingle Electrochemical anodization
Aluminum
Anodic aluminum oxide (AAO)
Aanodization
AAO films
Alaba Oladeji, Araoyinbo
Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
description Anodic aluminum oxide (AAO) films have been investigated and used in numerous products for more than 50 years. The morphologies of the AAO films can be classified into barrier-type and porous-type. Barrier-type films consist of compact amorphous alumina, while porous-type films comprise of a thin barrier layer next to the metal and an outer layer of porous alumina. There are limitations in the way nanoporous alumina has been fabricated. The limitations are the freezing of the electrolyte with a temperature controlled bath, very high potential and prolong anodizing time have also been used during AAO fabrication. In order to overcome these shortcomings associated with the fabrication of this porous alumina film at room temperature, this study aim to create a novel process to fabricate nanoporous alumina film with controlled pore diameters that is externally controlled by direct current circuit. The steps followed during the electronic circuit design set-up involved specification, design/cost, verification and testing of the circuit. The specification of the design is to address the issue of temperature, low potential anodization and the value of the most critical process parameter which is current, and the less critical parameters which are temperature and concentration of electrolyte. The next step of the design was the identification of important components i.e. capacitors and resistors that are crucial during the preliminary design stage. The components are cheap and provide a form of stability and control of the circuit. The verification and testing was done by computer simulation (PhET software kit) and practical testing of the circuit design. The computer simulations provided the information about the most suitable circuit design under different simulated conditions. The simulation identified a series connection of a single 60 V rated capacitor and a 500 ohms resistor to be the most suitable circuit design to limit the influence of the process parameters. The practical testing using different electrolyte concentration (i.e. 0.7 M, 1.5 M, and 2.2 M), different low potentials (i.e. 10 to 50 V) operating at room temperature identified the most critical current value to be less or equal to 150 mA. Any current value above this failed to produce a nanoporous alumina structure. A similar testing was also performed at higher temperature (50oC) to confirm the suitability of the circuit to operate at higher temperatures. The functionality of the circuit design is also equation based controlled by standard equations which can be operated via a direct circuit supply or alternating current supply, making the entire process flexible, accurate and precise. The room temperature and low potential anodization of aluminum were anodized under different electrolyte conditions for 1 hour, 3 hours, and 5 hours respectively. The scanning electron microscope (SEM) results show that the pores formed at different potentials and concentrations of electrolytes is within the range of 10 – 200 nm. The pores are randomly distributed all over the surface of the aluminum. As the applied voltage is increased with time subsequently the pores also increase in diameter. This results show that with the aid of the upgraded electrochemical cell controlled by the external dc circuit, nanoporous alumina were successfully fabricated at room temperature and high temperature with low potentials using a single step anodization technique which was suitable for AAO fabrication
format Thesis
author Alaba Oladeji, Araoyinbo
author_facet Alaba Oladeji, Araoyinbo
author_sort Alaba Oladeji, Araoyinbo
title Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
title_short Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
title_full Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
title_fullStr Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
title_full_unstemmed Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
title_sort electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit
granting_institution Universiti Malaysia Perlis (UniMAP)
granting_department School of Materials Engineering
url http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/1/P.1-24.pdf
http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/2/Full%20Text.pdf
_version_ 1747836816500719616
spelling my-unimap-428832016-09-19T08:11:08Z Electrochemical anodization of aluminum at room temperature by electronically controlled direct current circuit Alaba Oladeji, Araoyinbo Dr. Mohd Nazree Derman Anodic aluminum oxide (AAO) films have been investigated and used in numerous products for more than 50 years. The morphologies of the AAO films can be classified into barrier-type and porous-type. Barrier-type films consist of compact amorphous alumina, while porous-type films comprise of a thin barrier layer next to the metal and an outer layer of porous alumina. There are limitations in the way nanoporous alumina has been fabricated. The limitations are the freezing of the electrolyte with a temperature controlled bath, very high potential and prolong anodizing time have also been used during AAO fabrication. In order to overcome these shortcomings associated with the fabrication of this porous alumina film at room temperature, this study aim to create a novel process to fabricate nanoporous alumina film with controlled pore diameters that is externally controlled by direct current circuit. The steps followed during the electronic circuit design set-up involved specification, design/cost, verification and testing of the circuit. The specification of the design is to address the issue of temperature, low potential anodization and the value of the most critical process parameter which is current, and the less critical parameters which are temperature and concentration of electrolyte. The next step of the design was the identification of important components i.e. capacitors and resistors that are crucial during the preliminary design stage. The components are cheap and provide a form of stability and control of the circuit. The verification and testing was done by computer simulation (PhET software kit) and practical testing of the circuit design. The computer simulations provided the information about the most suitable circuit design under different simulated conditions. The simulation identified a series connection of a single 60 V rated capacitor and a 500 ohms resistor to be the most suitable circuit design to limit the influence of the process parameters. The practical testing using different electrolyte concentration (i.e. 0.7 M, 1.5 M, and 2.2 M), different low potentials (i.e. 10 to 50 V) operating at room temperature identified the most critical current value to be less or equal to 150 mA. Any current value above this failed to produce a nanoporous alumina structure. A similar testing was also performed at higher temperature (50oC) to confirm the suitability of the circuit to operate at higher temperatures. The functionality of the circuit design is also equation based controlled by standard equations which can be operated via a direct circuit supply or alternating current supply, making the entire process flexible, accurate and precise. The room temperature and low potential anodization of aluminum were anodized under different electrolyte conditions for 1 hour, 3 hours, and 5 hours respectively. The scanning electron microscope (SEM) results show that the pores formed at different potentials and concentrations of electrolytes is within the range of 10 – 200 nm. The pores are randomly distributed all over the surface of the aluminum. As the applied voltage is increased with time subsequently the pores also increase in diameter. This results show that with the aid of the upgraded electrochemical cell controlled by the external dc circuit, nanoporous alumina were successfully fabricated at room temperature and high temperature with low potentials using a single step anodization technique which was suitable for AAO fabrication Universiti Malaysia Perlis (UniMAP) 2014 Thesis en http://dspace.unimap.edu.my:80/xmlui/handle/123456789/42883 http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/1/P.1-24.pdf 5781d3d2843bacf9c651b4b7719ebc5e http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/2/Full%20Text.pdf 8f831c7d33cb77a439178e96b89486a1 http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/42883/3/license.txt 8a4605be74aa9ea9d79846c1fba20a33 Electrochemical anodization Aluminum Anodic aluminum oxide (AAO) Aanodization AAO films School of Materials Engineering