Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters

The influence of y-rays on the optical absorption and inelastic scattering, dielectric properties and conductivity of radiation-sensitive dyed polyvinyl alcohol (TBIPVA) film dosimeters containing chloral hydrate and acid-sensitive Thymol blue dye were evaluated for possible use as food irradiati...

Full description

Saved in:
Bibliographic Details
Main Author: Lepit, Ajis
Format: Thesis
Language:English
English
Published: 2004
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/6332/1/FSAS_2004_10.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.6332
record_format uketd_dc
spelling my-upm-ir.63322023-10-23T07:46:52Z Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters 2004-02 Lepit, Ajis The influence of y-rays on the optical absorption and inelastic scattering, dielectric properties and conductivity of radiation-sensitive dyed polyvinyl alcohol (TBIPVA) film dosimeters containing chloral hydrate and acid-sensitive Thymol blue dye were evaluated for possible use as food irradiation indicators. The dyed PVA films of different concentrations of chloral hydrate were irradiated with the absorbed doses ranging up to 12 kGy using y-rays from Cobalt-60. The dehydrochlorination of chloral hydrate and radiolysis of water molecules induced by ionising radiations accelerated the formation of hydrochloric acid in the polymer matrix, which caused the change in colour of the dosimeters from yellow to red at the critical doses depending on the concentration of chloral hydrate. This radiation-induced colour change was analysed using UV-Vis spectrometer, where the absorption spectra produced two visible maximal bands, peaking at 445 nm and 554 nm. The dose response at 445 nm and 554 nm increases and decreases respectively with absorbed dose. The inelastic Raman scattering spectra of photons corresponding to the Raman frequency shifts of unirradiated and irradiated films were measured using a dispersive Raman spectrometer, which provide direct evidence of molecular structure changes induced by ionising radiation and the subsequent chemical effects. The spectral intensities of Raman shifts at 815, 1984, 2350 and 2560 cm-' bands correspond to C-CI, C=O, C=C and S-H bonds respectively were studied, which provide the dose response to the molecular vibration of the dosimeters. From dielectric and conductivity studies it is found that the dyed polymer dosimeters are ionic polymer materials. The dielectric constant (E'), dielectric loss (E") and the electrical conductivity o(o) characteristics of the dosimeters were measured at different frequencies ranging from 20 Hz to I MHz. The dielectric constant and dielectric loss increase with absorbed dose at low frequencies and are independent of dose at higher frequencies for all chloral hydrate concentration. The AC conductivity (o) increases with absorbed dose and frequency due to the formation of radiationinduced free radicals, cations and anions in the polymer matrix and due to ejected electrons in the conduction bands. Thus, the resistance derived from the impedance measurement, decreases with absorbed dose. Finally, the films were subjected to stability tests using digital densitometry method at different time intervals during post-irradiation storage. The results show the change in optical density is minimal over the period of 70 days for all irradiated samples. This suggests the dosimeters have optical absorption stability characteristics for use as alternative radiationsensitive dosimeters in irradiation facilities as long as they are shielded from sunlight or fluorescent lighting by wrapping with black plastic bag. Gamma rays - Physiological effect 2004-02 Thesis http://psasir.upm.edu.my/id/eprint/6332/ http://psasir.upm.edu.my/id/eprint/6332/1/FSAS_2004_10.pdf text en public masters Universiti Putra Malaysia Gamma rays - Physiological effect Science and Environmental Studies Saion, Elias English
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
English
advisor Saion, Elias
topic Gamma rays - Physiological effect


spellingShingle Gamma rays - Physiological effect


Lepit, Ajis
Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters
description The influence of y-rays on the optical absorption and inelastic scattering, dielectric properties and conductivity of radiation-sensitive dyed polyvinyl alcohol (TBIPVA) film dosimeters containing chloral hydrate and acid-sensitive Thymol blue dye were evaluated for possible use as food irradiation indicators. The dyed PVA films of different concentrations of chloral hydrate were irradiated with the absorbed doses ranging up to 12 kGy using y-rays from Cobalt-60. The dehydrochlorination of chloral hydrate and radiolysis of water molecules induced by ionising radiations accelerated the formation of hydrochloric acid in the polymer matrix, which caused the change in colour of the dosimeters from yellow to red at the critical doses depending on the concentration of chloral hydrate. This radiation-induced colour change was analysed using UV-Vis spectrometer, where the absorption spectra produced two visible maximal bands, peaking at 445 nm and 554 nm. The dose response at 445 nm and 554 nm increases and decreases respectively with absorbed dose. The inelastic Raman scattering spectra of photons corresponding to the Raman frequency shifts of unirradiated and irradiated films were measured using a dispersive Raman spectrometer, which provide direct evidence of molecular structure changes induced by ionising radiation and the subsequent chemical effects. The spectral intensities of Raman shifts at 815, 1984, 2350 and 2560 cm-' bands correspond to C-CI, C=O, C=C and S-H bonds respectively were studied, which provide the dose response to the molecular vibration of the dosimeters. From dielectric and conductivity studies it is found that the dyed polymer dosimeters are ionic polymer materials. The dielectric constant (E'), dielectric loss (E") and the electrical conductivity o(o) characteristics of the dosimeters were measured at different frequencies ranging from 20 Hz to I MHz. The dielectric constant and dielectric loss increase with absorbed dose at low frequencies and are independent of dose at higher frequencies for all chloral hydrate concentration. The AC conductivity (o) increases with absorbed dose and frequency due to the formation of radiationinduced free radicals, cations and anions in the polymer matrix and due to ejected electrons in the conduction bands. Thus, the resistance derived from the impedance measurement, decreases with absorbed dose. Finally, the films were subjected to stability tests using digital densitometry method at different time intervals during post-irradiation storage. The results show the change in optical density is minimal over the period of 70 days for all irradiated samples. This suggests the dosimeters have optical absorption stability characteristics for use as alternative radiationsensitive dosimeters in irradiation facilities as long as they are shielded from sunlight or fluorescent lighting by wrapping with black plastic bag.
format Thesis
qualification_level Master's degree
author Lepit, Ajis
author_facet Lepit, Ajis
author_sort Lepit, Ajis
title Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters
title_short Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters
title_full Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters
title_fullStr Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters
title_full_unstemmed Influence of Gamma Radiation on Optical and Dielectric Properties of Dyed Polyvinyl Alcohol Film Dosimeters
title_sort influence of gamma radiation on optical and dielectric properties of dyed polyvinyl alcohol film dosimeters
granting_institution Universiti Putra Malaysia
granting_department Science and Environmental Studies
publishDate 2004
url http://psasir.upm.edu.my/id/eprint/6332/1/FSAS_2004_10.pdf
_version_ 1783725729994768384