Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field

Nowadays transformers have become essential for the electricity transmission and distribution network since the invention of transformers in late 1800s. The oil filled types transformer is commonly used and petroleum based MO has been widely used as transformer dielectric insulation fluid for decade...

Full description

Saved in:
Bibliographic Details
Main Author: Thien, Yee Von
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/77473/1/FK%202016%20122%20ir.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.77473
record_format uketd_dc
spelling my-upm-ir.774732022-01-27T06:59:33Z Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field 2016-01 Thien, Yee Von Nowadays transformers have become essential for the electricity transmission and distribution network since the invention of transformers in late 1800s. The oil filled types transformer is commonly used and petroleum based MO has been widely used as transformer dielectric insulation fluid for decades. However, the usage of MO has several drawbacks such as non-biodegradable, low flash and fire points and could contaminate the soil and waterways if serious spill occurs. Recently, vegetable oil is introduced as the potential candidate, since it is biodegradable, non-toxic and has better environmental performance with high flash and fire points. The seed based natural ester has been applied successfully as dielectric insulation fluid in small and medium transformers. In Malaysia, due to the huge plantation of PO, the types of vegetable oils considered for transformer applications are PO and CO. Before these oils can be applied in transformers, extensive assessment on its performance need to be carried out since the in-service failure could be costly. Among the common assessment is the lightning impulse strength, which is one of the important parameter for insulation design of a transformer. This work presents the experimental studies on the lightning impulse breakdown voltages of PO and CO under various gap distances. Three different variations of PO and one sample of CO were considered in all tests. The lightning breakdown voltage test was carried out under non-uniform electric field configuration where the gap distances were set in the range of 2-25 mm. Three testing methods which are rising voltage, up-and-down and multiple-level were used to determine the breakdown voltage results. The lightning breakdown voltages performances of PO and CO compared with MO were analysed. All lightning breakdown voltages were analysed and the withstand voltages were evaluated through Weibull distribution. It was revealed that there is a bright future possibility of using PO as alternative insulation fluids in transformers where the breakdown voltages performances of PO and CO are comparable with MO under positive lightning impulse. However, the negative lightning impulse breakdown voltage of MO is found to be higher than both PO and CO, which might due to their different chemical structural. Based on this study, the lightning breakdown strengths of PO and CO at I% and 50% breakdown probability can be acquired through the empirical formulas produced where the breakdown voltage at large gap distances can be predicted which are important for transformers insulation design. The knowledge of the lightning impulse characteristics of PO and CO are obtained and can be used for further improvement in future works. Electric insulators and insulation - Oils Electric transformers - Design and construction Lightning 2016-01 Thesis http://psasir.upm.edu.my/id/eprint/77473/ http://psasir.upm.edu.my/id/eprint/77473/1/FK%202016%20122%20ir.pdf text en public masters Universiti Putra Malaysia Electric insulators and insulation - Oils Electric transformers - Design and construction Lightning Azis, Norhafiz
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
advisor Azis, Norhafiz
topic Electric insulators and insulation - Oils
Electric transformers - Design and construction
Lightning
spellingShingle Electric insulators and insulation - Oils
Electric transformers - Design and construction
Lightning
Thien, Yee Von
Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
description Nowadays transformers have become essential for the electricity transmission and distribution network since the invention of transformers in late 1800s. The oil filled types transformer is commonly used and petroleum based MO has been widely used as transformer dielectric insulation fluid for decades. However, the usage of MO has several drawbacks such as non-biodegradable, low flash and fire points and could contaminate the soil and waterways if serious spill occurs. Recently, vegetable oil is introduced as the potential candidate, since it is biodegradable, non-toxic and has better environmental performance with high flash and fire points. The seed based natural ester has been applied successfully as dielectric insulation fluid in small and medium transformers. In Malaysia, due to the huge plantation of PO, the types of vegetable oils considered for transformer applications are PO and CO. Before these oils can be applied in transformers, extensive assessment on its performance need to be carried out since the in-service failure could be costly. Among the common assessment is the lightning impulse strength, which is one of the important parameter for insulation design of a transformer. This work presents the experimental studies on the lightning impulse breakdown voltages of PO and CO under various gap distances. Three different variations of PO and one sample of CO were considered in all tests. The lightning breakdown voltage test was carried out under non-uniform electric field configuration where the gap distances were set in the range of 2-25 mm. Three testing methods which are rising voltage, up-and-down and multiple-level were used to determine the breakdown voltage results. The lightning breakdown voltages performances of PO and CO compared with MO were analysed. All lightning breakdown voltages were analysed and the withstand voltages were evaluated through Weibull distribution. It was revealed that there is a bright future possibility of using PO as alternative insulation fluids in transformers where the breakdown voltages performances of PO and CO are comparable with MO under positive lightning impulse. However, the negative lightning impulse breakdown voltage of MO is found to be higher than both PO and CO, which might due to their different chemical structural. Based on this study, the lightning breakdown strengths of PO and CO at I% and 50% breakdown probability can be acquired through the empirical formulas produced where the breakdown voltage at large gap distances can be predicted which are important for transformers insulation design. The knowledge of the lightning impulse characteristics of PO and CO are obtained and can be used for further improvement in future works.
format Thesis
qualification_level Master's degree
author Thien, Yee Von
author_facet Thien, Yee Von
author_sort Thien, Yee Von
title Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
title_short Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
title_full Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
title_fullStr Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
title_full_unstemmed Lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
title_sort lightning impulse breakdown performances of palm oil and coconut oil under non-uniform field
granting_institution Universiti Putra Malaysia
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/77473/1/FK%202016%20122%20ir.pdf
_version_ 1747813228588564480