Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse

The environment that suits the growth of most kind of crops is very crucial in order to guarantee high quality yields that can be controlled according to the desired parameters and not easily damaged or stunted during its growth. Naturally Ventilated Greenhouse (NVGH) is one of the methods to att...

Full description

Saved in:
Bibliographic Details
Main Author: Sulaiman, Ahmad Syafik Suraidi
Format: Thesis
Language:English
English
Published: 2008
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/7870/1/ABS_%3D%3D%3D__FK_2008_93.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.7870
record_format uketd_dc
spelling my-upm-ir.78702013-05-27T07:36:55Z Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse 2008 Sulaiman, Ahmad Syafik Suraidi The environment that suits the growth of most kind of crops is very crucial in order to guarantee high quality yields that can be controlled according to the desired parameters and not easily damaged or stunted during its growth. Naturally Ventilated Greenhouse (NVGH) is one of the methods to attain the controlled environment and it is proven to be highly effective in controlling the suitable environment for most kind of plants or vegetables. Furthermore, NVGH can save energy where mechanical, electrical and labour power required is very small, require no controlling procedures or complicated handling, suitable to tropical climate and the cost to build is very low compared to other plant protection structures. The tropical country climate is inconsistent all year long and even though the NVGH can control its environment, it has some weaknesses in which the air and the temperature inside the NVGH can be easily influenced by the outside conditions of the structure. Most kinds of crops require temperature between 20-35ºC and relative air humidity between 80-90% in order to ensure a standard quality harvest. An evaporative cooling system using four misting fans was studied inside a NVGH of 10m width, 50m long and 4m high. The aim was to modify the environment inside the NVGH so that it could control the inside temperature between 20-35ºC and relative humidity between 80-90% all day long. Other environmental parameters such as light intensity, outside air temperature and carbon dioxide were also studied in order to see the correlation and modification effect on the environment in the NVGH. All environment data studied was recorded and statistically analyzed using the Statistical Package for the Social Science (SPSS) software. Temperature inside the NVGH was found to be strongly correlated with time (min), outside temperature, light intensity and relative air humidity while carbon dioxide only gave a moderate effect on the temperature inside the NVGH. The correlation equation between temperature inside the NVGH is shown in the following equation: T1= -0.001 (T) +0.001 (L)-0.103 (H) +0.447 (T2) +21.949 where T1= inside temperature (°C), T= Time (min) L= Light Intensity (W·m-2), H=Relative Humidity (%) and T2= outside temperature (°C). The misting fans also turned out to be effective in controlling the temperature inside the NVGH to remain between 20-35ºC and relative air humidity between 80-90% all day long compared to NVGH that is not equipped with the misting fans. The inside temperature, light intensity and carbon dioxide under the NVGH attached with misting fans were found to be lower than NVGH without misting fans. The relative humidity inside the NVGH attached with misting fans was found to be higher than the NVGH without misting fans. Crop such as chili and cauliflowers were able to grow favourably inside the NVGH attached with the misting fans and the crop growth performance indicates a linear trend during the growing period. Greenhouse management Microclimatology 2008 Thesis http://psasir.upm.edu.my/id/eprint/7870/ http://psasir.upm.edu.my/id/eprint/7870/1/ABS_%3D%3D%3D__FK_2008_93.pdf application/pdf en public masters Universiti Putra Malaysia Greenhouse management Microclimatology Faculty of Engineering English
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
English
topic Greenhouse management
Microclimatology

spellingShingle Greenhouse management
Microclimatology

Sulaiman, Ahmad Syafik Suraidi
Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse
description The environment that suits the growth of most kind of crops is very crucial in order to guarantee high quality yields that can be controlled according to the desired parameters and not easily damaged or stunted during its growth. Naturally Ventilated Greenhouse (NVGH) is one of the methods to attain the controlled environment and it is proven to be highly effective in controlling the suitable environment for most kind of plants or vegetables. Furthermore, NVGH can save energy where mechanical, electrical and labour power required is very small, require no controlling procedures or complicated handling, suitable to tropical climate and the cost to build is very low compared to other plant protection structures. The tropical country climate is inconsistent all year long and even though the NVGH can control its environment, it has some weaknesses in which the air and the temperature inside the NVGH can be easily influenced by the outside conditions of the structure. Most kinds of crops require temperature between 20-35ºC and relative air humidity between 80-90% in order to ensure a standard quality harvest. An evaporative cooling system using four misting fans was studied inside a NVGH of 10m width, 50m long and 4m high. The aim was to modify the environment inside the NVGH so that it could control the inside temperature between 20-35ºC and relative humidity between 80-90% all day long. Other environmental parameters such as light intensity, outside air temperature and carbon dioxide were also studied in order to see the correlation and modification effect on the environment in the NVGH. All environment data studied was recorded and statistically analyzed using the Statistical Package for the Social Science (SPSS) software. Temperature inside the NVGH was found to be strongly correlated with time (min), outside temperature, light intensity and relative air humidity while carbon dioxide only gave a moderate effect on the temperature inside the NVGH. The correlation equation between temperature inside the NVGH is shown in the following equation: T1= -0.001 (T) +0.001 (L)-0.103 (H) +0.447 (T2) +21.949 where T1= inside temperature (°C), T= Time (min) L= Light Intensity (W·m-2), H=Relative Humidity (%) and T2= outside temperature (°C). The misting fans also turned out to be effective in controlling the temperature inside the NVGH to remain between 20-35ºC and relative air humidity between 80-90% all day long compared to NVGH that is not equipped with the misting fans. The inside temperature, light intensity and carbon dioxide under the NVGH attached with misting fans were found to be lower than NVGH without misting fans. The relative humidity inside the NVGH attached with misting fans was found to be higher than the NVGH without misting fans. Crop such as chili and cauliflowers were able to grow favourably inside the NVGH attached with the misting fans and the crop growth performance indicates a linear trend during the growing period.
format Thesis
qualification_level Master's degree
author Sulaiman, Ahmad Syafik Suraidi
author_facet Sulaiman, Ahmad Syafik Suraidi
author_sort Sulaiman, Ahmad Syafik Suraidi
title Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse
title_short Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse
title_full Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse
title_fullStr Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse
title_full_unstemmed Effect of Evaporative Cooling by Misting Fan on Microclimate of a Naturally Ventilated Greenhouse
title_sort effect of evaporative cooling by misting fan on microclimate of a naturally ventilated greenhouse
granting_institution Universiti Putra Malaysia
granting_department Faculty of Engineering
publishDate 2008
url http://psasir.upm.edu.my/id/eprint/7870/1/ABS_%3D%3D%3D__FK_2008_93.pdf