Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia

Gempa bumi sederhana yang terjadi pada 5 Jun 2015 di Ranau, Sabah, dengan magnitude 5.9 telah menyebabkan kerosakan pada bangunan-bangunan. Dengan itu, adalah penting untuk mempertimbangkan rekabentuk seismik untuk bangunan-bangunan baru di wilayah tersebut. Dalam rekabentuk seismik, suatu konsep ya...

Full description

Saved in:
Bibliographic Details
Main Author: Adiyanto, Mohd Irwan
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://eprints.usm.my/41773/1/Influence_Of_Behaviour_Factor_On_Seismic_Design_And_Performance_Of_Reinforced_Concrete_Moment_Resisting_Frame_In_Malaysia.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.41773
record_format uketd_dc
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic T Technology
T Technology
spellingShingle T Technology
T Technology
Adiyanto, Mohd Irwan
Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia
description Gempa bumi sederhana yang terjadi pada 5 Jun 2015 di Ranau, Sabah, dengan magnitude 5.9 telah menyebabkan kerosakan pada bangunan-bangunan. Dengan itu, adalah penting untuk mempertimbangkan rekabentuk seismik untuk bangunan-bangunan baru di wilayah tersebut. Dalam rekabentuk seismik, suatu konsep yang dinamakan sebagai faktor kelakuan yang berkait rapat dengan kemuluran telah dicadangkan. Baru-baru ini terdapat komen dan cadangan bahawa nilai faktor kelakuan sekarang patut diganti. Dengan itu, adalah penting untuk mengkaji kesan perubahan nilai faktor kelakuan dari dua perspektif iaitu reka bentuk dan prestasi. Selain itu, aturan histeresis mewakili kelakuan struktur apabila dikenakan beban kitaran sisi seperti gempa bumi. Kesesuaian sesuatu aturan histeresis untuk digunakan dalam program komputer bagi analisis sejarah masa tidak linear perlu diperiksa. Di wilayah seismik tinggi, kejadian gempa bumi berulang tidak boleh diabaikan dalam analisis struktur kerana ia mencetuskan kerosakan yang lebih besar ke atas sistem struktur. Dengan itu, pengaruh gempa bumi berulang di wilayah seismik medium di Malaysia juga perlu disiasat. Tesis ini membentangkan pengaruh faktor kelakuan ke atas rekabentuk seismik bagi bangunan kerangka penahan momen konkrit bertetulang di Malaysia. Rekabentuk seismik telah dijalankan untuk kemuluran kelas pertengahan dengan faktor kelakuan dari 2.3 hingga 5.5 merujuk kepada Eurocode 8. Ujian beban kitaran sisi juga telah dijalankan untuk mengkaji kelakuan struktur apabila dikenakan beban sisi. Ia juga penting untuk memeriksa kesesuaian Modified Takeda Degrading Stiffness sebagai aturan histeresis bagi analisis sejarah masa tidak linear. Akhir sekali, prestasi struktur bagi semua kerangka yang telah direkabentuk dinilai dengan analisis sejarah masa tidak linear dengan mempertimbangkan gempa-gempa tunggal dan berulang. Kajian ini menyumbang kepada penilaian terhadap nilai faktor kelakuan berdasarkan rekabentuk dan prestasi struktur. Selain itu, kajian ini juga memeriksa kesesuaian Modified Takeda Degrading Stiffness sebagai aturan histeresis. Sebagai kesimpulan, nilai faktor kelakuan sangat mempengaruhi rekabentuk seismik. Jumlah berat besi pengukuhan boleh dikurangkan sehingga 36.2% dengan menggunakan faktor kelakuan tinggi dalam rekabentuk. Daripada ujian beban kitaran sisi, boleh disimpulkan bahawa Modified Takeda Degrading Stiffness sesuai untuk digunakan sebagai aturan histeresis dalam analisis sejarah masa tidak linear. Nilai kekakuan nyahbeban, α adalah bersamaan 0.1 sementara nilai kekakuan pembebanan semula, β adalah bersamaan 0.4. Berdasarkan penilaian ke atas prestasi struktur, magnitud maksimum bagi anjakan antara tingkat disebabkan oleh gempa bumi berulang mencapai sehingga 30.1% hingga 40.6% lebih tinggi daripada gempa bumi tunggal. Dengan itu, faktor kelakuan dari 2.3 hingga 5.5 adalah diterima untuk digunakan bagi rekabentuk seismik bangunan kerangka penahan momen konkrit bertetulang baru di atas tanah jenis B di wilayah seismik pertengahan di Malaysia. Di atas tanah jenis D, faktor kelakuan dihadkan dari 2.3 hingga 4.54. _________________________________________________________________________________________________________________________ A moderate earthquake which occurred on 5th June 2015 in Ranau, Sabah, with Mw5.9 had caused damages on buildings. Therefore, it is important to consider seismic design for new buildings in that region. In seismic design, a concept namely as behaviour factor, q which strongly relates with ductility was proposed. Recently, there are comments and suggestion that the current value of behaviour factor, q shall be replaced. Therefore, it is importance to study the effect of changing the value of behaviour factor, q from two different perspectives which is design and performance. Besides, hysteresis rule represents the structural behaviour when subjected to cyclic lateral load like earthquake. The suitability of a hysteresis rule to be used in computer program for nonlinear time history analysis has to be checked. In high seismic region, the occurrence of repeated earthquake cannot be neglected in structural analysis since it induces greater damage on structural system. Therefore, the influence of repeated earthquake in medium seismic region in Malaysia also has to be investigated. This thesis presents the influence of behaviour factor, q on seismic design for reinforced concrete moment resisting frame buildings in Malaysia. The seismic design had been conducted for ductility class medium with behaviour factor, q from 2.3 to 5.5 by referring to Eurocode 8. The cyclic loading test also had been conducted to investigate the structural behaviour when subjected to lateral load. It is also important to check to suitability of Modified Takeda Degrading Stiffness as hysteresis rule for nonlinear time history analysis. Finally, the structural performance of all designed frames had been evaluated by using nonlinear time history analysis considering single and repeated earthquakes. This study contributes to the evaluation on the value of behaviour factor, q based on design and structural performance. Beside, this study also checked the suitability of Modified Takeda Degrading Stiffness as hysteresis rule. As a conclusion, the value of behaviour factor, q is strongly influencing the seismic design. The total weight of steel reinforcement can be reduced up to 36.2% by using higher behaviour factor, q in design. From cyclic loading test, it can be concluded that the Modified Takeda Degrading Stiffness is suitable to be used as hysteresis rule in nonlinear time history analysis. The value of unloading stiffness, α is equal to 0.1 while the value of reloading stiffness, β is equal to 0.4. Based on evaluation on structural performance, the magnitude of maximum interstorey drift ratio caused by repeated earthquake reached up to 30.1% to 40.6% higher than the single earthquake. Therefore, the behaviour factor, q from 2.3 to 5.5 is acceptable to be used for seismic design of new reinforced concrete moment resisting frame building on Soil Type B in medium seismic region in Malaysia. On Soil Type D, the behaviour factor, q is limited from 2.3 to 4.54.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Adiyanto, Mohd Irwan
author_facet Adiyanto, Mohd Irwan
author_sort Adiyanto, Mohd Irwan
title Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia
title_short Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia
title_full Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia
title_fullStr Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia
title_full_unstemmed Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia
title_sort influence of behaviour factor on seismic design and performance of reinforced concrete moment resisting frame in malaysia
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Kejuruteraan Awam
publishDate 2016
url http://eprints.usm.my/41773/1/Influence_Of_Behaviour_Factor_On_Seismic_Design_And_Performance_Of_Reinforced_Concrete_Moment_Resisting_Frame_In_Malaysia.pdf
_version_ 1747820966889652224
spelling my-usm-ep.417732018-09-06T08:27:12Z Influence Of Behaviour Factor On Seismic Design And Performance Of Reinforced Concrete Moment Resisting Frame In Malaysia 2016-02 Adiyanto, Mohd Irwan T Technology TA1-2040 Engineering (General). Civil engineering (General) Gempa bumi sederhana yang terjadi pada 5 Jun 2015 di Ranau, Sabah, dengan magnitude 5.9 telah menyebabkan kerosakan pada bangunan-bangunan. Dengan itu, adalah penting untuk mempertimbangkan rekabentuk seismik untuk bangunan-bangunan baru di wilayah tersebut. Dalam rekabentuk seismik, suatu konsep yang dinamakan sebagai faktor kelakuan yang berkait rapat dengan kemuluran telah dicadangkan. Baru-baru ini terdapat komen dan cadangan bahawa nilai faktor kelakuan sekarang patut diganti. Dengan itu, adalah penting untuk mengkaji kesan perubahan nilai faktor kelakuan dari dua perspektif iaitu reka bentuk dan prestasi. Selain itu, aturan histeresis mewakili kelakuan struktur apabila dikenakan beban kitaran sisi seperti gempa bumi. Kesesuaian sesuatu aturan histeresis untuk digunakan dalam program komputer bagi analisis sejarah masa tidak linear perlu diperiksa. Di wilayah seismik tinggi, kejadian gempa bumi berulang tidak boleh diabaikan dalam analisis struktur kerana ia mencetuskan kerosakan yang lebih besar ke atas sistem struktur. Dengan itu, pengaruh gempa bumi berulang di wilayah seismik medium di Malaysia juga perlu disiasat. Tesis ini membentangkan pengaruh faktor kelakuan ke atas rekabentuk seismik bagi bangunan kerangka penahan momen konkrit bertetulang di Malaysia. Rekabentuk seismik telah dijalankan untuk kemuluran kelas pertengahan dengan faktor kelakuan dari 2.3 hingga 5.5 merujuk kepada Eurocode 8. Ujian beban kitaran sisi juga telah dijalankan untuk mengkaji kelakuan struktur apabila dikenakan beban sisi. Ia juga penting untuk memeriksa kesesuaian Modified Takeda Degrading Stiffness sebagai aturan histeresis bagi analisis sejarah masa tidak linear. Akhir sekali, prestasi struktur bagi semua kerangka yang telah direkabentuk dinilai dengan analisis sejarah masa tidak linear dengan mempertimbangkan gempa-gempa tunggal dan berulang. Kajian ini menyumbang kepada penilaian terhadap nilai faktor kelakuan berdasarkan rekabentuk dan prestasi struktur. Selain itu, kajian ini juga memeriksa kesesuaian Modified Takeda Degrading Stiffness sebagai aturan histeresis. Sebagai kesimpulan, nilai faktor kelakuan sangat mempengaruhi rekabentuk seismik. Jumlah berat besi pengukuhan boleh dikurangkan sehingga 36.2% dengan menggunakan faktor kelakuan tinggi dalam rekabentuk. Daripada ujian beban kitaran sisi, boleh disimpulkan bahawa Modified Takeda Degrading Stiffness sesuai untuk digunakan sebagai aturan histeresis dalam analisis sejarah masa tidak linear. Nilai kekakuan nyahbeban, α adalah bersamaan 0.1 sementara nilai kekakuan pembebanan semula, β adalah bersamaan 0.4. Berdasarkan penilaian ke atas prestasi struktur, magnitud maksimum bagi anjakan antara tingkat disebabkan oleh gempa bumi berulang mencapai sehingga 30.1% hingga 40.6% lebih tinggi daripada gempa bumi tunggal. Dengan itu, faktor kelakuan dari 2.3 hingga 5.5 adalah diterima untuk digunakan bagi rekabentuk seismik bangunan kerangka penahan momen konkrit bertetulang baru di atas tanah jenis B di wilayah seismik pertengahan di Malaysia. Di atas tanah jenis D, faktor kelakuan dihadkan dari 2.3 hingga 4.54. _________________________________________________________________________________________________________________________ A moderate earthquake which occurred on 5th June 2015 in Ranau, Sabah, with Mw5.9 had caused damages on buildings. Therefore, it is important to consider seismic design for new buildings in that region. In seismic design, a concept namely as behaviour factor, q which strongly relates with ductility was proposed. Recently, there are comments and suggestion that the current value of behaviour factor, q shall be replaced. Therefore, it is importance to study the effect of changing the value of behaviour factor, q from two different perspectives which is design and performance. Besides, hysteresis rule represents the structural behaviour when subjected to cyclic lateral load like earthquake. The suitability of a hysteresis rule to be used in computer program for nonlinear time history analysis has to be checked. In high seismic region, the occurrence of repeated earthquake cannot be neglected in structural analysis since it induces greater damage on structural system. Therefore, the influence of repeated earthquake in medium seismic region in Malaysia also has to be investigated. This thesis presents the influence of behaviour factor, q on seismic design for reinforced concrete moment resisting frame buildings in Malaysia. The seismic design had been conducted for ductility class medium with behaviour factor, q from 2.3 to 5.5 by referring to Eurocode 8. The cyclic loading test also had been conducted to investigate the structural behaviour when subjected to lateral load. It is also important to check to suitability of Modified Takeda Degrading Stiffness as hysteresis rule for nonlinear time history analysis. Finally, the structural performance of all designed frames had been evaluated by using nonlinear time history analysis considering single and repeated earthquakes. This study contributes to the evaluation on the value of behaviour factor, q based on design and structural performance. Beside, this study also checked the suitability of Modified Takeda Degrading Stiffness as hysteresis rule. As a conclusion, the value of behaviour factor, q is strongly influencing the seismic design. The total weight of steel reinforcement can be reduced up to 36.2% by using higher behaviour factor, q in design. From cyclic loading test, it can be concluded that the Modified Takeda Degrading Stiffness is suitable to be used as hysteresis rule in nonlinear time history analysis. The value of unloading stiffness, α is equal to 0.1 while the value of reloading stiffness, β is equal to 0.4. Based on evaluation on structural performance, the magnitude of maximum interstorey drift ratio caused by repeated earthquake reached up to 30.1% to 40.6% higher than the single earthquake. Therefore, the behaviour factor, q from 2.3 to 5.5 is acceptable to be used for seismic design of new reinforced concrete moment resisting frame building on Soil Type B in medium seismic region in Malaysia. On Soil Type D, the behaviour factor, q is limited from 2.3 to 4.54. 2016-02 Thesis http://eprints.usm.my/41773/ http://eprints.usm.my/41773/1/Influence_Of_Behaviour_Factor_On_Seismic_Design_And_Performance_Of_Reinforced_Concrete_Moment_Resisting_Frame_In_Malaysia.pdf application/pdf en public phd doctoral Universiti Sains Malaysia Pusat Pengajian Kejuruteraan Awam