Influence Of Force Reduction Factor On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake
Current practices in earthquake engineering only apply single earthquake motion on building structure during modelling and analysis. However, in real earthquake event, the tremors always occurred repeatedly until two or three times after the first tremor. This phenomenon can affect the stiffness and...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2011
|
Subjects: | |
Online Access: | http://eprints.usm.my/43410/1/MOHD%20IRWAN%20BIN%20ADIYANTO.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-usm-ep.43410 |
---|---|
record_format |
uketd_dc |
spelling |
my-usm-ep.434102019-04-12T05:26:30Z Influence Of Force Reduction Factor On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake 2011-09 Adiyanto, Mohd Irwan TA1-2040 Engineering (General). Civil engineering (General) Current practices in earthquake engineering only apply single earthquake motion on building structure during modelling and analysis. However, in real earthquake event, the tremors always occurred repeatedly until two or three times after the first tremor. This phenomenon can affect the stiffness and strength of the structural system. Due to lack of time any rehabilitation action is impractical. Thus, the building may experience greater damage due to several repeated tremors. This thesis presents the seismic performance of 3 and 18 storey generic reinforced concrete building subjected to single and repeated earthquake. 2011-09 Thesis http://eprints.usm.my/43410/ http://eprints.usm.my/43410/1/MOHD%20IRWAN%20BIN%20ADIYANTO.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Kejuteraan Awam |
institution |
Universiti Sains Malaysia |
collection |
USM Institutional Repository |
language |
English |
topic |
TA1-2040 Engineering (General) Civil engineering (General) |
spellingShingle |
TA1-2040 Engineering (General) Civil engineering (General) Adiyanto, Mohd Irwan Influence Of Force Reduction Factor On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake |
description |
Current practices in earthquake engineering only apply single earthquake motion on building structure during modelling and analysis. However, in real earthquake event, the tremors always occurred repeatedly until two or three times after the first tremor. This phenomenon can affect the stiffness and strength of the structural system. Due to lack of time any rehabilitation action is impractical. Thus, the building may experience greater damage due to several repeated tremors. This thesis presents the seismic performance of 3 and 18 storey generic reinforced concrete building subjected to single and repeated earthquake. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Adiyanto, Mohd Irwan |
author_facet |
Adiyanto, Mohd Irwan |
author_sort |
Adiyanto, Mohd Irwan |
title |
Influence Of Force Reduction Factor
On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake |
title_short |
Influence Of Force Reduction Factor
On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake |
title_full |
Influence Of Force Reduction Factor
On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake |
title_fullStr |
Influence Of Force Reduction Factor
On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake |
title_full_unstemmed |
Influence Of Force Reduction Factor
On The Interstorey Drift Of RC Building Under Repeated Near-Field Earthquake |
title_sort |
influence of force reduction factor
on the interstorey drift of rc building under repeated near-field earthquake |
granting_institution |
Universiti Sains Malaysia |
granting_department |
Pusat Pengajian Kejuteraan Awam |
publishDate |
2011 |
url |
http://eprints.usm.my/43410/1/MOHD%20IRWAN%20BIN%20ADIYANTO.pdf |
_version_ |
1747821208075763712 |