Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging

Polyvinyl acetate (PVA) is a type of adhesive that is squishy and viscous. The advantages of PVA materials are non-toxic, low cost, non-resistant to water and need simple preparation. The aim of the study is to explore the feasibility, suitability, and compatibility of PVA as tissue mimicking phanto...

Full description

Saved in:
Bibliographic Details
Main Author: Chaw, Nurbranda
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.usm.my/50997/1/Nurbrand%20Chaw-24%20pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.50997
record_format uketd_dc
spelling my-usm-ep.509972021-12-29T03:57:58Z Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging 2020-07 Chaw, Nurbranda R Medicine Polyvinyl acetate (PVA) is a type of adhesive that is squishy and viscous. The advantages of PVA materials are non-toxic, low cost, non-resistant to water and need simple preparation. The aim of the study is to explore the feasibility, suitability, and compatibility of PVA as tissue mimicking phantom for MRI studies. In this study, four PVA slime phantoms were fabricated with different additives that are water, oil, milk, and salt. Three other phantoms were prepared as controls materials that are water, oil, and milk. A total of seven phantoms were prepared and left for several days at room temperature to ensure no air bubbles formed in the phantoms. The T1, T2 and diffusion tensor imaging scan was performed using Philips Achieva 3 Tesla MRI system at the Department of Radiology, Hospital Universiti Sains Malaysia (HUSM). The signal intensity of the T1-weighted images (T1WI), T2-weighted images (T2WI), and diffusion-weighted images (DWI) of all phantoms were measured. Then, graphs of signal intensity vs TR and signal intensity vs TE were plotted to determine the T1 and T2 relaxation times, respectively. The diffusion coefficient (D) of the phantoms was also determined based on calculation using the specific equation. DTI parametric values of all phantoms were also recorded. The T1, T2, and D values were compared with normal and abnormal human tissues. The findings from this study showed that for all phantoms, T1 curves increases exponentially with TR while T2 curves decreases exponentially with increasing TE. The T1 and T2 relaxation as well as diffusion coefficient of the specific phantoms show similar characteristics to some human tissues. However, ghosting artefacts were observed in T2WI and DWI which need to be removed in future studies. To conclude, fabrication of the PVA slime phantom that mimics human tissues for MRI studies are feasible. 2020-07 Thesis http://eprints.usm.my/50997/ http://eprints.usm.my/50997/1/Nurbrand%20Chaw-24%20pages.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Kesihatan
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic R Medicine
spellingShingle R Medicine
Chaw, Nurbranda
Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging
description Polyvinyl acetate (PVA) is a type of adhesive that is squishy and viscous. The advantages of PVA materials are non-toxic, low cost, non-resistant to water and need simple preparation. The aim of the study is to explore the feasibility, suitability, and compatibility of PVA as tissue mimicking phantom for MRI studies. In this study, four PVA slime phantoms were fabricated with different additives that are water, oil, milk, and salt. Three other phantoms were prepared as controls materials that are water, oil, and milk. A total of seven phantoms were prepared and left for several days at room temperature to ensure no air bubbles formed in the phantoms. The T1, T2 and diffusion tensor imaging scan was performed using Philips Achieva 3 Tesla MRI system at the Department of Radiology, Hospital Universiti Sains Malaysia (HUSM). The signal intensity of the T1-weighted images (T1WI), T2-weighted images (T2WI), and diffusion-weighted images (DWI) of all phantoms were measured. Then, graphs of signal intensity vs TR and signal intensity vs TE were plotted to determine the T1 and T2 relaxation times, respectively. The diffusion coefficient (D) of the phantoms was also determined based on calculation using the specific equation. DTI parametric values of all phantoms were also recorded. The T1, T2, and D values were compared with normal and abnormal human tissues. The findings from this study showed that for all phantoms, T1 curves increases exponentially with TR while T2 curves decreases exponentially with increasing TE. The T1 and T2 relaxation as well as diffusion coefficient of the specific phantoms show similar characteristics to some human tissues. However, ghosting artefacts were observed in T2WI and DWI which need to be removed in future studies. To conclude, fabrication of the PVA slime phantom that mimics human tissues for MRI studies are feasible.
format Thesis
qualification_level Master's degree
author Chaw, Nurbranda
author_facet Chaw, Nurbranda
author_sort Chaw, Nurbranda
title Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging
title_short Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging
title_full Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging
title_fullStr Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging
title_full_unstemmed Fabrication and characterization of polyvintl acetate slime phantom for T1-weighted, T2-weighted, and diffusion tensor magnetic resonance imaging
title_sort fabrication and characterization of polyvintl acetate slime phantom for t1-weighted, t2-weighted, and diffusion tensor magnetic resonance imaging
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Kesihatan
publishDate 2020
url http://eprints.usm.my/50997/1/Nurbrand%20Chaw-24%20pages.pdf
_version_ 1747822050829926400