Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency

Objectives: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy in the world. Some countries have practiced fluorescent spot test (FST) as a neonatal screening method since the 1980s. However, FST has its own limitations. Quantitative assays such as the careSTARTTM...

Full description

Saved in:
Bibliographic Details
Main Author: Halim, Sarah Abdul
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.usm.my/60408/1/Sarah%20Abdul%20Halim-24%20pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.60408
record_format uketd_dc
spelling my-usm-ep.604082024-05-06T04:15:38Z Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency 2022 Halim, Sarah Abdul R Medicine RA440-440.87 Study and teaching. Research RC799-869 Diseases of the digestive system. Gastroenterology Objectives: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy in the world. Some countries have practiced fluorescent spot test (FST) as a neonatal screening method since the 1980s. However, FST has its own limitations. Quantitative assays such as the careSTARTTM BioSensor1 have been demonstrated to be able to overcome some of these limitations. The objectives of this study are to compare the performance of FST with BioSensor1 in detecting G6PD deficiency in neonates and to verify the reference range of G6PD level for cord blood using BioSensor1. Methods: This study was a cross sectional study involving 455 neonates born in Hospital Universiti Sains Malaysia (Hospital USM), Kelantan, Malaysia beginning June 2020 until December 2020. Two millilitres of cord blood were taken in EDTA bottles to be analysed with BioSensor1 and dried cord blood spots on filter paper were sent for FST to determine the levels of G6PD. Demographics data and birth characteristics were taken from labour room records. Data was recorded and analysed using the Statistical Package for the Social Software (SPSS) version 27. P-value less than 0.05 were considered as significant. Results: The sensitivity of FST was 91% whilst its specificity was 97% at 30% cut-off G6PD activity level. In contrast, at 60% cut-off G6PD activity level, the sensitivity drastically decreased to 29% whilst the specificity was 100%. The overall prevalence of G6PD deficiency was 5.1% and 17.8% for FST and Biosensor1 respectively, demonstrating a drastic difference between the two tests (p < 0.001). The mean G6PD level for term neonates was 6.84 U/gHb whilst for preterm neonates was 6.63 U/gHb. Using independent T-Test, there was no significant difference in the mean G6PD levels between term and preterm neonates. There was also no significant association between different gestational age groups, maternal blood group and birthweight with mean G6PD level when tested using one way ANOVA test. Conclusions: FST has low sensitivity at 60% cut-off G6PD level. This cut-off level reflects intermediate G6PD activity, hence FST missed a significant proportion of G6PD intermediate individuals in our study. At the same time, the prevalence of G6PD deficiency significantly increased with the use of BioSensor1. Gestational age, birthweight and maternal blood group do not have significant association with G6PD level. In a budget constrained facility, it is recommended to use quantitative enzyme assay to screen female neonates and to use FST for male neonates especially in areas where G6PD deficiency is prevalent. 2022 Thesis http://eprints.usm.my/60408/ http://eprints.usm.my/60408/1/Sarah%20Abdul%20Halim-24%20pages.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Perubatan
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic R Medicine
R Medicine
R Medicine
spellingShingle R Medicine
R Medicine
R Medicine
Halim, Sarah Abdul
Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
description Objectives: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy in the world. Some countries have practiced fluorescent spot test (FST) as a neonatal screening method since the 1980s. However, FST has its own limitations. Quantitative assays such as the careSTARTTM BioSensor1 have been demonstrated to be able to overcome some of these limitations. The objectives of this study are to compare the performance of FST with BioSensor1 in detecting G6PD deficiency in neonates and to verify the reference range of G6PD level for cord blood using BioSensor1. Methods: This study was a cross sectional study involving 455 neonates born in Hospital Universiti Sains Malaysia (Hospital USM), Kelantan, Malaysia beginning June 2020 until December 2020. Two millilitres of cord blood were taken in EDTA bottles to be analysed with BioSensor1 and dried cord blood spots on filter paper were sent for FST to determine the levels of G6PD. Demographics data and birth characteristics were taken from labour room records. Data was recorded and analysed using the Statistical Package for the Social Software (SPSS) version 27. P-value less than 0.05 were considered as significant. Results: The sensitivity of FST was 91% whilst its specificity was 97% at 30% cut-off G6PD activity level. In contrast, at 60% cut-off G6PD activity level, the sensitivity drastically decreased to 29% whilst the specificity was 100%. The overall prevalence of G6PD deficiency was 5.1% and 17.8% for FST and Biosensor1 respectively, demonstrating a drastic difference between the two tests (p < 0.001). The mean G6PD level for term neonates was 6.84 U/gHb whilst for preterm neonates was 6.63 U/gHb. Using independent T-Test, there was no significant difference in the mean G6PD levels between term and preterm neonates. There was also no significant association between different gestational age groups, maternal blood group and birthweight with mean G6PD level when tested using one way ANOVA test. Conclusions: FST has low sensitivity at 60% cut-off G6PD level. This cut-off level reflects intermediate G6PD activity, hence FST missed a significant proportion of G6PD intermediate individuals in our study. At the same time, the prevalence of G6PD deficiency significantly increased with the use of BioSensor1. Gestational age, birthweight and maternal blood group do not have significant association with G6PD level. In a budget constrained facility, it is recommended to use quantitative enzyme assay to screen female neonates and to use FST for male neonates especially in areas where G6PD deficiency is prevalent.
format Thesis
qualification_level Master's degree
author Halim, Sarah Abdul
author_facet Halim, Sarah Abdul
author_sort Halim, Sarah Abdul
title Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
title_short Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
title_full Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
title_fullStr Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
title_full_unstemmed Comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
title_sort comparison of fluorescent spot test against quantitative enzyme assay for detection of glucose-6-phosphate dehydrogenase deficiency
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Perubatan
publishDate 2022
url http://eprints.usm.my/60408/1/Sarah%20Abdul%20Halim-24%20pages.pdf
_version_ 1804888931654696960