Effects Of Opening On The Behaviour Of Axially Loaded Firedclay Single Leaf Wall
The area around openings in the form of doors, windows, and for mechanical and electrical services in axially loaded structural masonry panels are subjected to high stress concentration. There is a possibility of tension developing around these openings near the corners. Furthermore, the presence...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2006
|
Subjects: | |
Online Access: | http://eprints.usm.my/60412/1/tesis%20effect%20of%20opening%20on%20the%20behaviour%20CUT.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The area around openings in the form of doors, windows, and for mechanical
and electrical services in axially loaded structural masonry panels are subjected
to high stress concentration. There is a possibility of tension developing around
these openings near the corners. Furthermore, the presence of these openings could affect the ultimate strength of the masonry panel. |
---|