Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].

Rawatan tumor otak malignan melalui Terapi Tawanan Neutron Boron (BNCT) memerlukan punca neutron dengan fluks yang tinggi. Reaktor TRIGA Mark II Malaysia diselidiki untuk pepasangan BNCT yang dicadangkan. The treatment of the malignant brain tumor through Boron Neutron Capture Therapy (BNCT) requ...

全面介紹

Saved in:
書目詳細資料
主要作者: Eid Abdel_Munem, Eid Mahmoud
格式: Thesis
語言:English
出版: 2008
主題:
在線閱讀:http://eprints.usm.my/9091/1/NEUTRON_FLUX_MEASUREMENTS_WITH_MONTE_CARLO_VERIFICATION_AT_THE_THERMAL_COLUMN_OF_A_TRIGA_MARK_II_REACTOR.pdf
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my-usm-ep.9091
record_format uketd_dc
spelling my-usm-ep.90912017-03-22T02:23:47Z Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb]. 2008-01 Eid Abdel_Munem, Eid Mahmoud QC793-793.5 Elementary particle physics Rawatan tumor otak malignan melalui Terapi Tawanan Neutron Boron (BNCT) memerlukan punca neutron dengan fluks yang tinggi. Reaktor TRIGA Mark II Malaysia diselidiki untuk pepasangan BNCT yang dicadangkan. The treatment of the malignant brain tumor through Boron Neutron Capture Therapy (BNCT) requires a high-flux neutron source. The Malaysian TRIGA Mark II reactor was investigated for a proposed BNCT facility. 2008-01 Thesis http://eprints.usm.my/9091/ http://eprints.usm.my/9091/1/NEUTRON_FLUX_MEASUREMENTS_WITH_MONTE_CARLO_VERIFICATION_AT_THE_THERMAL_COLUMN_OF_A_TRIGA_MARK_II_REACTOR.pdf application/pdf en public phd doctoral Universiti Sains Malaysia Pusat Pengajian Sains Fizik
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic QC793-793.5 Elementary particle physics
spellingShingle QC793-793.5 Elementary particle physics
Eid Abdel_Munem, Eid Mahmoud
Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].
description Rawatan tumor otak malignan melalui Terapi Tawanan Neutron Boron (BNCT) memerlukan punca neutron dengan fluks yang tinggi. Reaktor TRIGA Mark II Malaysia diselidiki untuk pepasangan BNCT yang dicadangkan. The treatment of the malignant brain tumor through Boron Neutron Capture Therapy (BNCT) requires a high-flux neutron source. The Malaysian TRIGA Mark II reactor was investigated for a proposed BNCT facility.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Eid Abdel_Munem, Eid Mahmoud
author_facet Eid Abdel_Munem, Eid Mahmoud
author_sort Eid Abdel_Munem, Eid Mahmoud
title Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].
title_short Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].
title_full Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].
title_fullStr Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].
title_full_unstemmed Neutron Flux Measurements With Monte Carlo Verification At The Thermal Column Of A Triga Mark II Reactor : Feasibility Study For A BNCT Facility [QC793.5.N462 E34 2008 f rb].
title_sort neutron flux measurements with monte carlo verification at the thermal column of a triga mark ii reactor : feasibility study for a bnct facility [qc793.5.n462 e34 2008 f rb].
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Fizik
publishDate 2008
url http://eprints.usm.my/9091/1/NEUTRON_FLUX_MEASUREMENTS_WITH_MONTE_CARLO_VERIFICATION_AT_THE_THERMAL_COLUMN_OF_A_TRIGA_MARK_II_REACTOR.pdf
_version_ 1747819751747354624