Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM

Thermal comfort is a condition of mind which expresses satisfaction with the surrounding thermal environment. A person’s perception of thermal comfort is affected by air temperature, mean radiant temperature, air velocity, relative humidity, metabolic rate for work activities and clothing insulation...

Full description

Saved in:
Bibliographic Details
Main Author: Yong Thau Foong, Stanley
Format: Thesis
Language:English
English
Published: 2008
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/13831/1/Measurement_Of_Thermal_Comfort_At_Classroom_A_Case_Study_In_UTeM_-_24_Pages.pdf
http://eprints.utem.edu.my/id/eprint/13831/2/Measurement_Of_Thermal_Comfort_At_Classroom_A_Case_Study_In_UTeM.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.13831
record_format uketd_dc
spelling my-utem-ep.138312015-05-28T04:34:28Z Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM 2008 Yong Thau Foong, Stanley T Technology (General) TH Building construction Thermal comfort is a condition of mind which expresses satisfaction with the surrounding thermal environment. A person’s perception of thermal comfort is affected by air temperature, mean radiant temperature, air velocity, relative humidity, metabolic rate for work activities and clothing insulation. Thermal comfort in classrooms has to be considered seriously because of the negative influence on learning and the potential for energy conservation through careful temperature control. In recognition the importance of thermal comfort in classroom, the objectives of study are to determine the response of occupants regarding to thermal comfort at classroom in UTeM, measure the actual thermal comfort at classroom in UTeM, and propose the solutions in order to improve or maintain the thermal comfort at classroom in UTeM. Determination of occupants’ responses was obtained through observation method associated with a questionnaire. Measurement of actual thermal comfort in classroom is performed via direct technical measurement associated with a thermal comfort monitor to determine the PMV and PPD. Meanwhile, the thermal comfort improvement was proposed based on engineering controls and administrative controls. The results of occupants’ responses show that BK 12 in morning and afternoon sessions and BK 5 at evening session are the most dissatisfied classrooms. However, the results of direct technical measurement show also that the BK 12 in morning and afternoon sessions and BK 5 at evening session are the most dissatisfied classrooms. When compared between each other, the direct technical measurement has confirmed the findings of occupants’ responses at morning session, but it is not at afternoon and evening sessions as they show the negative correlations. 2008 Thesis http://eprints.utem.edu.my/id/eprint/13831/ http://eprints.utem.edu.my/id/eprint/13831/1/Measurement_Of_Thermal_Comfort_At_Classroom_A_Case_Study_In_UTeM_-_24_Pages.pdf application/pdf en public http://eprints.utem.edu.my/id/eprint/13831/2/Measurement_Of_Thermal_Comfort_At_Classroom_A_Case_Study_In_UTeM.pdf application/pdf en validuser http://library.utem.edu.my:8000/elmu/index.jsp?module=webopac-d&action=fullDisplayRetriever.jsp&szMaterialNo=0000048751 masters UTeM Faculty Of Manufacturing Engineering
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
English
topic T Technology (General)
TH Building construction
spellingShingle T Technology (General)
TH Building construction
Yong Thau Foong, Stanley
Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM
description Thermal comfort is a condition of mind which expresses satisfaction with the surrounding thermal environment. A person’s perception of thermal comfort is affected by air temperature, mean radiant temperature, air velocity, relative humidity, metabolic rate for work activities and clothing insulation. Thermal comfort in classrooms has to be considered seriously because of the negative influence on learning and the potential for energy conservation through careful temperature control. In recognition the importance of thermal comfort in classroom, the objectives of study are to determine the response of occupants regarding to thermal comfort at classroom in UTeM, measure the actual thermal comfort at classroom in UTeM, and propose the solutions in order to improve or maintain the thermal comfort at classroom in UTeM. Determination of occupants’ responses was obtained through observation method associated with a questionnaire. Measurement of actual thermal comfort in classroom is performed via direct technical measurement associated with a thermal comfort monitor to determine the PMV and PPD. Meanwhile, the thermal comfort improvement was proposed based on engineering controls and administrative controls. The results of occupants’ responses show that BK 12 in morning and afternoon sessions and BK 5 at evening session are the most dissatisfied classrooms. However, the results of direct technical measurement show also that the BK 12 in morning and afternoon sessions and BK 5 at evening session are the most dissatisfied classrooms. When compared between each other, the direct technical measurement has confirmed the findings of occupants’ responses at morning session, but it is not at afternoon and evening sessions as they show the negative correlations.
format Thesis
qualification_level Master's degree
author Yong Thau Foong, Stanley
author_facet Yong Thau Foong, Stanley
author_sort Yong Thau Foong, Stanley
title Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM
title_short Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM
title_full Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM
title_fullStr Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM
title_full_unstemmed Measurement Of Thermal Comfort At Classroom: A Case Study In UTeM
title_sort measurement of thermal comfort at classroom: a case study in utem
granting_institution UTeM
granting_department Faculty Of Manufacturing Engineering
publishDate 2008
url http://eprints.utem.edu.my/id/eprint/13831/1/Measurement_Of_Thermal_Comfort_At_Classroom_A_Case_Study_In_UTeM_-_24_Pages.pdf
http://eprints.utem.edu.my/id/eprint/13831/2/Measurement_Of_Thermal_Comfort_At_Classroom_A_Case_Study_In_UTeM.pdf
_version_ 1747833813152563200