Ergonomic Design Chair For Postpartum Mothers

This study was carried out in the Ayer Keroh Health Clinic following registration with the National Medical Research Register (NMRR). Its objective is to address the concerns faced by postpartum mothers while being seated in the waiting area of the clinic because of pain at in their episiotomy wound...

Full description

Saved in:
Bibliographic Details
Main Author: Sumaidy, Eliyana Sari
Format: Thesis
Language:English
English
Published: 2016
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/20776/1/Ergonomic%20Design%20Chair%20For%20Postpartum%20Mothers%20-%20Eliyana%20Sari%20Sumaidy%20-%2024%20Pages.pdf
http://eprints.utem.edu.my/id/eprint/20776/2/Ergonomic%20Design%20Chair%20For%20Postpartum%20Mothers%20-%20Eliyana%20Sari%20Sumaidy.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utem-ep.20776
record_format uketd_dc
institution Universiti Teknikal Malaysia Melaka
collection UTeM Repository
language English
English
topic T Technology (General)
TS Manufactures
spellingShingle T Technology (General)
TS Manufactures
Sumaidy, Eliyana Sari
Ergonomic Design Chair For Postpartum Mothers
description This study was carried out in the Ayer Keroh Health Clinic following registration with the National Medical Research Register (NMRR). Its objective is to address the concerns faced by postpartum mothers while being seated in the waiting area of the clinic because of pain at in their episiotomy wound. The problem areas were identified, which included the technical requirements needed by postpartum mothers in designing an ergonomic chair. A new design feature(s) was included in the chair, and then corroborated with regards to feasibility and usability. Considering the technical requirements, a questionnaire is conducted and data analysis is done utilising AHP and HOQ. The chosen design from the three conceptual designs was conceived in the Solidworks software. For chair dimensions, the 5th, 50th and 95th percentile is computed using Minitab17 from the anthropometry measurements of postpartum mothers. The CES edupack is utilised for choosing material for specific parts of the chair. Attributes of an ergonomic chair include simple to use and adjustable armrest, comfort and ease of cleaning. The corroboration was done with respect to the technical method by utilising pressure mapping and subjective methodology from the survey. The comparison of respondents’ contact pressure is done using the present chair in the clinic’s waiting area and the model of the ergonomic chair. It was noted that the contact pressure decreased at the perineal area. The projected outcome from the chair design is able to scrutinise the postpartum mothers’ technical requirements and the ergonomic chair’s designs will decrease the episiotomy wound. This research could undergo further scrutiny in terms of designing an ergonomic chair which is apt for postpartum mothers and offers comfort to 95 percent of users. Going forward, the chair should be designed with an adjustable height and in accordance with body dimensions of postpartum mothers, from 1st percentile to 99th percentile for greater comfort.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Sumaidy, Eliyana Sari
author_facet Sumaidy, Eliyana Sari
author_sort Sumaidy, Eliyana Sari
title Ergonomic Design Chair For Postpartum Mothers
title_short Ergonomic Design Chair For Postpartum Mothers
title_full Ergonomic Design Chair For Postpartum Mothers
title_fullStr Ergonomic Design Chair For Postpartum Mothers
title_full_unstemmed Ergonomic Design Chair For Postpartum Mothers
title_sort ergonomic design chair for postpartum mothers
granting_institution Universiti Teknikal Malaysia Melaka
granting_department Faculty of Manufacturing Engineering
publishDate 2016
url http://eprints.utem.edu.my/id/eprint/20776/1/Ergonomic%20Design%20Chair%20For%20Postpartum%20Mothers%20-%20Eliyana%20Sari%20Sumaidy%20-%2024%20Pages.pdf
http://eprints.utem.edu.my/id/eprint/20776/2/Ergonomic%20Design%20Chair%20For%20Postpartum%20Mothers%20-%20Eliyana%20Sari%20Sumaidy.pdf
_version_ 1747834003539361792
spelling my-utem-ep.207762021-10-08T17:01:27Z Ergonomic Design Chair For Postpartum Mothers 2016 Sumaidy, Eliyana Sari T Technology (General) TS Manufactures This study was carried out in the Ayer Keroh Health Clinic following registration with the National Medical Research Register (NMRR). Its objective is to address the concerns faced by postpartum mothers while being seated in the waiting area of the clinic because of pain at in their episiotomy wound. The problem areas were identified, which included the technical requirements needed by postpartum mothers in designing an ergonomic chair. A new design feature(s) was included in the chair, and then corroborated with regards to feasibility and usability. Considering the technical requirements, a questionnaire is conducted and data analysis is done utilising AHP and HOQ. The chosen design from the three conceptual designs was conceived in the Solidworks software. For chair dimensions, the 5th, 50th and 95th percentile is computed using Minitab17 from the anthropometry measurements of postpartum mothers. The CES edupack is utilised for choosing material for specific parts of the chair. Attributes of an ergonomic chair include simple to use and adjustable armrest, comfort and ease of cleaning. The corroboration was done with respect to the technical method by utilising pressure mapping and subjective methodology from the survey. The comparison of respondents’ contact pressure is done using the present chair in the clinic’s waiting area and the model of the ergonomic chair. It was noted that the contact pressure decreased at the perineal area. The projected outcome from the chair design is able to scrutinise the postpartum mothers’ technical requirements and the ergonomic chair’s designs will decrease the episiotomy wound. This research could undergo further scrutiny in terms of designing an ergonomic chair which is apt for postpartum mothers and offers comfort to 95 percent of users. Going forward, the chair should be designed with an adjustable height and in accordance with body dimensions of postpartum mothers, from 1st percentile to 99th percentile for greater comfort. 2016 Thesis http://eprints.utem.edu.my/id/eprint/20776/ http://eprints.utem.edu.my/id/eprint/20776/1/Ergonomic%20Design%20Chair%20For%20Postpartum%20Mothers%20-%20Eliyana%20Sari%20Sumaidy%20-%2024%20Pages.pdf text en public http://eprints.utem.edu.my/id/eprint/20776/2/Ergonomic%20Design%20Chair%20For%20Postpartum%20Mothers%20-%20Eliyana%20Sari%20Sumaidy.pdf text en validuser https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=104911 mphil masters Universiti Teknikal Malaysia Melaka Faculty of Manufacturing Engineering 1. Akao, Y. and Mazur, G.H., 2003. The leading edge in QFD: past, present and future. International Journal of Quality & Reliability Management,20(1), pp.20-35. 2. Albers, L., Garcia, J., Renfrew, M., McCandlish, R. and Elbourne, D., 1999. Distribution of genital tract trauma in childbirth and related postnatal pain. Birth, 26(1), pp.11-17. 3. Albrizio, A., 2007. Biometry and anthropometry: from Galton to constitutional medicine. Journal of Anthropological Sciences, 85, pp.101-123. 4. Anderson, S., Goede, B., Kramer, D., Leupp, M., Nemunaitis, G., Samir, H. M., Pourazady, M., 2013. Correlating Air Cushion Pressure To Maximum Interface Pressure On The Buttocks. Resna Annual Conference. Ohio. 5. Andrews, V., Thakar, R., Sultan, A.H. and Jones, P.W., 2008. Evaluation of postpartum perineal pain and dyspareunia—a prospective study. European Journal of Obstetrics & Gynecology and Reproductive Biology, 137(2), pp.152-156. 6. Aradmehr, M., Azhari, S. and Shakeri, M.T., 2015. Study of Factors Associated with Postoperative Pain Following Episiotomy in Primiparous Women at Mashhad Omalbanin Hospital in 2012. Journal of Midwifery and Reproductive Health, 3(1), pp.305-314. 7. Bradley, C.S., Kennedy, C.M. and Nygaard, I.E., 2005. Pelvic floor symptoms and lifestyle factors in older women. Journal of Women's Health, 14(2), pp.128-136. 8. Carter, A.S., Baker, C.W. and Brownell, K.D., 2000. Body mass index, eating attitudes, and symptoms of depression and anxiety in pregnancy and the postpartum period. Psychosomatic Medicine, 62(2), pp.264-270. 9. Chang, S.R., Chen, K.H., Lin, H.H., Chao, Y.M.Y. and Lai, Y.H., 2011. Comparison of the effects of episiotomy and no episiotomy on pain, urinary incontinence, and sexual function 3 months postpartum: a prospective follow-up study. International journal of nursing studies, 48(4), pp.409-418. 10. Chumlea, W.M., and Guo, S.S., 2000. Assessment and Prevalence of Obesity: Application of New Methods to a Major Problem.Endocrine, 13(2), pp. 135–42. 11. Cogill, B., 2003. Anthropometric indicators measurement guide. 12. Crowell, D.T., 1995. Weight change in the postpartum period: a review of the literature.Journal of nurse-midwifery, 40(5), pp.418-423. 13. Daruis, D.D.I., Deros, B.M. and Nor, M.J.M., 2011. Malaysian sitting anthropometry for seat fit parameters. Human Factors and Ergonomics in Manufacturing & Service Industries, 21(5), pp.443-455. 14. Daruis, D.D.I., Md Deros, B. and Mohd Nor, M.J., 2007, December. Anthropometric study of Malaysian military cadets. In International Conference on Ergonomics (pp. 3-5). 15. Day, R.G., 1993. Quality function deployment: Linking a company with its customers. Asq Press. 16. DeLancey, J.O., 2005. The hidden epidemic of pelvic floor dysfunction: achievable goals for improved prevention and treatment. American journal of obstetrics and gynecology, 192(5), pp.1488-1495. 17. Deros, B., Mohamad, D., Ismail, A.R., Soon, O.W., Lee, K.C. and Nordin, M.S., 2009. Recommended chair and work surfaces dimensions of VDT tasks for Malaysian citizens.European Journal of Scientific Research, 34(2), pp.156-167. 18. Deros, B.M., Daruis, D.D.I. and Nor, M.J.M., 2008. Fundamental sitting anthropometric and differences among Malaysian Malays, Chinese and Indians. In Advanced Manufacturing Research Group’08 Seminar (Vol. 1). 19. East, C.E., Begg, L., Henshall, N.E., Marchant, P.R. and Wallace, K., 2012. Local cooling for relieving pain from perineal trauma sustained during childbirth. The Cochrane Library. Eitzen, I., 2004. Pressure mapping in seating: a frequency analysis approach. Archives of physical medicine and rehabilitation, 85(7), pp.1136-1140. 20. Goldberg, J., Holtz, D., Hyslop, T. and Tolosa, J.E., 2002. Has the use of routine episiotomy decreased? Examination of episiotomy rates from 1983 to 2000. Obstetrics & gynecology, 99(3), pp.395-400. 21. Golozar, S., Namjouian, F., Latifi, S.M. and Mirahi, A., 2011. Evaluating the effect of oral bromelain (pineapple) on episiotomy wound healing in primiparus women. Feyz Journals of Kashan University of Medical Sciences, 15(2). 22. Gonzalez, M., 2001. QFD; A Road to Listening to Customer Q3 Needs. 23. González, M.E., Quesada, G. and Bahill, A.T., 2003. Improving product design using quality function deployment: the school furniture case in developing countries. Quality Engineering, 16(1), pp.45-56. 24. Gore, S.A., Brown, D.M. and West, D.S., 2003. The role of postpartum weight retention in obesity among women: a review of the evidence. Annals of Behavioral Medicine, 26(2), pp.149-159. 25. Gould, D., 2007. Perineal tears and episiotomy. Nursing Standard, 21(52), pp.41-46. 26. Gray, D., 1999. Pressure ulcer prevention and treatment: the Transair range. British Journal Of Nursing-London-Mark Allen Publishing Limited-, 8, pp.454-458. 27. Gunderson, E.P. and Abrams, B., 1999. Epidemiology of gestational weight gain and body weight changes after pregnancy. Epidemiologic reviews, 21(2), pp.261-275. 28. Gunderson, E.P., Abrams, B. and Selvin, S., 2001. Does the pattern of postpartum weight change differ according to pregravid body size?.International Journal of Obesity & Related Metabolic Disorders, 25(6). 29. Hastings, J.D., 2000. Seating assessment and planning. Physical medicine and rehabilitation clinics of North America, 11(1), pp.183-208. 30. Hedayati, H., Parsons, J. and Crowther, C.A., 2005. Topically applied anaesthetics for treating perineal pain after childbirth. The Cochrane Library. 31. Hedge, A. and Breeuwsma, K., n.d. Chair Design Beyond gender and Age. spine, 6, p.7. 32. Ho, J.J., Pattanittum, P., Japaraj, R.P., Turner, T., Swadpanich, U., Crowther, C.A. and SEA-ORCHID Study Group, 2010. Influence of training in the use and generation of evidence on episiotomy practice and perineal trauma. International Journal of Gynecology & Obstetrics, 111(1), pp.13-18. 33. Institute of Medicine (US). Subcommittee on Nutritional Status, Weight Gain during Pregnancy, Institute of Medicine (US). Subcommittee on Dietary Intake and Nutrient Supplements during Pregnancy, 1990. Nutrition during pregnancy: part I, weight gain: part II, nutrient supplements. Natl Academy Pr. 34. Irwin, J.O., 1959. Biometric method, past, present, and future. Biometrics, 15(3), pp.363- 375. 35. Jahdi, F., Kheyrkhah, M., Haghani, H., Taghizadeh, M., Mehrabi, E. and Eghdampour, F., 2011. The effect of Aloe Vera ointment on the intensity of perineal pain following episiotomy: A randomized blind clinical trial. Asrar. Journal of Sabzevar School of Medical Sciences, 18(4), pp.243-249. 36. Jordan, M., 2012. Device for extracorporeal magnetic innervation. U.S. Patent Application 14/004,814. 37. Kakade, S.V., 2015. Effectiveness of Infrared Lamp Therapy on Healing of Episiotomy Wound among Post Natal Mothers. Health Science Journal. 38. Kindberg, S., Stehouwer, M., Hvidman, L. and Henriksen, T.B., 2008. Postpartum perineal repair performed by midwives: a randomised trial comparing two suture techniques leaving the skin unsutured. BJOG: An International Journal of Obstetrics & Gynaecology, 115(4), pp.472-479. 39. Kuczmarski, R.J., Ogden, C.L., Guo, S.S., Grummer-Strawn, L.M., Flegal, K.M., Mei, Z., Wei, R., Curtin, L.R., Roche, A.F. and Johnson, C.L., 2002. 2000 CDC Growth Charts for the United States: methods and development. Vital and health statistics. Series 11, Data from the national health survey, (246), pp.1-190. 40. Lam, K.W., Wong, H.S. and Pun, T.C., 2006. The practice of episiotomy in public hospitals in Hong Kong. 41. Lin, Y.C., Wang, M.J.J. and Wang, E.M., 2004. The comparisons of anthropometric characteristics among four peoples in East Asia. Applied Ergonomics, 35(2), pp.173-178. 42. Macarthur, A., Imarengiaye, C., Tureanu, L. and Downey, K., 2010. A randomized, double-blind, placebo-controlled trial of epidural morphine analgesia after vaginal delivery. Anesthesia & Analgesia, 110(1), pp.159-164. 43. Mack, K.B., Phillips, C., Jain, N. and Koroluk, L.D., 2013. Relationship between body mass index percentile and skeletal maturation and dental development in orthodontic patients. American Journal of Orthodontics and Dentofacial Orthopedics, 143(2), pp.228- 234. 44. Malassigne, P., Nelson, A.L., Cors, M.W. and Amerson, T.L., 2000. Design of the advanced commode-shower chair for spinal cord-injured individuals.Journal of rehabilitation research and development, 37(3), p.373. 45. McCandlish, R., 2001. Perineal trauma: prevention and treatment. Journal of Midwifery & Women’s Health, 46(6), pp.396-401. 46. Mohamed, H.A.E. and El-Nagger, N.S., 2012. Effect of self perineal care instructions on episiotomy pain and wound healing of postpartum women. J Am Sci, 8(6), pp.640-50. 47. Muda, S.M., 2014. Maintaining women's perineal integrity: participatory action research study. 48. Nakui, S., 1992. Gaining a Strategic Advantage: Implementing Proactive Quality Function Deployment. In Transactions from the Fourth Symposium on Quality Function Deployment (pp. 361-368). 49. Oliveira, S.M., Silva, F., Riesco, M.L., Latorre, M.D.R. and Nobre, M.R., 2012. Comparison of application times for ice packs used to relieve perineal pain after normal birth: a randomised clinical trial. Journal of clinical nursing, 21(23-24), pp.3382-3391. 50. Olson, C.M., Demment, M.M., Carling, S.J. and Strawderman, M.S., 2010. Associations between mothers' and their children's weights at 4 years of age. Childhood Obesity (Formerly Obesity and Weight Management), 6(4), pp.201-207. 51. Panero, J. and Zelnik, M., 2014. Human dimension and interior space: a source book of design reference standards. Watson-Guptill. 52. Pazandeh, F., Savadzadeh, S., Mojab, F. and Alavi Majd, H., 2009. Effects of chamomile essence aromatherapy on episiotomy pain of primiparous women. Journal of Shahid Beheshti School of Nursing & Midwifery, 18(62), pp.926-926. 53. Pheasant, S. T., & Haslegrave, C. M. 2006. Bodyspace: anthropometry, ergonomics, and the design of work: CRC Press. 54. Prathima, P. and Anuchitra, S., 2015. Correlation Between Bmi And Pregnancy Outcome Among Postnatal Mothers With Pregnancy Induced Hypertension In Selected Hospitals Bangalore. Nitte University Journal of Health Science, 5(1), p.62. 55. Rowland, M., Foxcroft, L., Hopman, W.M. and Patel, R., 2005. Breastfeeding and sexuality immediately postpartum. Canadian Family Physician, 51(10), pp.1366-1367. 56. Shelton, F., Barnett, R. and Meyer, E., 1998. Full-body interface pressure testing as a method for performance evaluation of clinical support surfaces. Applied Ergonomics, 29(6), pp.491-497. 57. Soltani, H. and Fraser, R.B., 2000. A longitudinal study of maternal anthropometric changes in normal weight, overweight and obese women during pregnancy and postpartum. British Journal of Nutrition, 84(01), pp.95-101. 58. Stashower, M.E., Stashower Mitchell E, 2011. Method of providing post-partum treatment for enhancing comfort, physical and psychological well-being. U.S. Patent 7,895,057. 59. Steen, M. and Marchant, P., 2007. Ice packs and cooling gel pads versus no localised treatment for relief of perineal pain: a randomised controlled trial. Evidence-Based Midwifery, 5(1), pp.16-23. 60. Steen, M., Briggs, M. and King, D., 2006. Alleviating postnatal perineal trauma: To cool or not to cool?. British Journal of Midwifery, 14(5). 61. Steen, M., Cooper, K., Marchant, P., Griffiths-Jones, M. and Walker, J., 2000. A randomised controlled trial to compare the effectiveness of icepacks and Epifoam with cooling maternity gel pads at alleviating postnatal perineal trauma. Midwifery, 16(1), pp.48-55. 62. Syed Abd Rashid, S.N., Rosnah, M.Y., Hamid, T.A., Lina Goh, S.C. and Mohd Rizal, H., 2005. Ageing in place: Towards an ergonomically designed home environment for older Malaysians.Gerontechnology, 3(4), p.238. 63. Taha, Z., Nazaruddin, I., Ghazilla, R.A. and Agha, S.S.S., 2001. Anthropometrics data of Malaysian industrial workers. In 6th Pan Pacific Conference on Occupational Ergonomics. 64. Ulijaszek, S.J., 2005. Anthropometry: the individual and the population (Vol. 14).Cambridge University Press. 65. Utkualp, N. and Ercan, I., 2015. Anthropometric measurements usage in medical sciences. BioMed research international, 2015. 66. Vernon, M.M., Young-Hyman, D. and Looney, S.W., 2010. Maternal stress, physical activity, and body mass index during new mothers' first year postpartum. Women & health, 50(6), pp.544-562. 67. WHO, E.C., 2004. Appropriate body-mass index for Asian populations and its implications for policy and intervention strategies. Lancet (London, England), 363(9403), p.157. 68. Zainur, R.Z. and Loh, K.Y., 2006. Postpartum morbidity-what we can do. Medical Journal Of Malaysia, 61(5), p.651.