Development of portable 10 stages Marx Generator

High voltage equipments are often placed in open air and they are often exposed to lightning strike as well as surge voltage. They are sustaining high surge voltage during the lightning phenomena. To achieve better protection of all such power equipments and quality power supply, these voltages shou...

Full description

Saved in:
Bibliographic Details
Main Author: .Kh. Eljugmani, Ahmed Saeed
Format: Thesis
Language:English
English
English
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/1286/2/AHMED%20SAEED%20.KH.%20ELJUGMANI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1286/1/24p%20AHMED%20SAEED%20.KH.%20ELJUGMANI.pdf
http://eprints.uthm.edu.my/1286/3/AHMED%20SAEED%20.KH.%20ELJUGMANI%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1286
record_format uketd_dc
spelling my-uthm-ep.12862021-09-30T07:09:33Z Development of portable 10 stages Marx Generator 2015-06 .Kh. Eljugmani, Ahmed Saeed TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers High voltage equipments are often placed in open air and they are often exposed to lightning strike as well as surge voltage. They are sustaining high surge voltage during the lightning phenomena. To achieve better protection of all such power equipments and quality power supply, these voltages should be simulated and test the above said equipments in laboratories, Marx generator is the commonly used. This generator produces lightning impulse voltages of 1.2/50 μs duration. This project describes the development of a cost effective and easily portable compact 10 stages Marx Generator capable of producing lightning impulses voltage up to 25kV. In addition, three different experimental circuits of HV DC supplies have been made. The highest output was 2.5 kV DC which was taken as the main supply for the experimental and simulated Marx generator circuit. This generator can be used by small scale industries and academic institutions to demonstrate impulse voltages and also to perform testing on insulators of lower rating in laboratory. A total of 10 stages of both simulated, experimental Marx impulse generator circuit was designed and the impulse waves were recorded. The simulated recorded impulse waveform was compared with the standard impulse wave with front time of 1.2 μ seconds and tail time of 50 μ seconds. Both of circuits, the efficiency of each stages was calculated and the percentage of error in the front and tail time was also found out as well as the effects of the circuit parameters on the impulse waveform characteristics were also studied. The simulation was done with the help of Pspice Software Simulation. In this work, the comparison in terms of magnitude of the experimental and simulated 10 stages Marx generator circuit has been carried out as well as its illustrative curve has been drawn. These results have confirmed the validity of the proposed method and they were in close agreement. 2015-06 Thesis http://eprints.uthm.edu.my/1286/ http://eprints.uthm.edu.my/1286/2/AHMED%20SAEED%20.KH.%20ELJUGMANI%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/1286/1/24p%20AHMED%20SAEED%20.KH.%20ELJUGMANI.pdf text en public http://eprints.uthm.edu.my/1286/3/AHMED%20SAEED%20.KH.%20ELJUGMANI%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Faculty of Electrical and Electronics Engineering
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TK2000-2891 Dynamoelectric machinery and auxiliaries
Including generators, motors, transformers
spellingShingle TK2000-2891 Dynamoelectric machinery and auxiliaries
Including generators, motors, transformers
.Kh. Eljugmani, Ahmed Saeed
Development of portable 10 stages Marx Generator
description High voltage equipments are often placed in open air and they are often exposed to lightning strike as well as surge voltage. They are sustaining high surge voltage during the lightning phenomena. To achieve better protection of all such power equipments and quality power supply, these voltages should be simulated and test the above said equipments in laboratories, Marx generator is the commonly used. This generator produces lightning impulse voltages of 1.2/50 μs duration. This project describes the development of a cost effective and easily portable compact 10 stages Marx Generator capable of producing lightning impulses voltage up to 25kV. In addition, three different experimental circuits of HV DC supplies have been made. The highest output was 2.5 kV DC which was taken as the main supply for the experimental and simulated Marx generator circuit. This generator can be used by small scale industries and academic institutions to demonstrate impulse voltages and also to perform testing on insulators of lower rating in laboratory. A total of 10 stages of both simulated, experimental Marx impulse generator circuit was designed and the impulse waves were recorded. The simulated recorded impulse waveform was compared with the standard impulse wave with front time of 1.2 μ seconds and tail time of 50 μ seconds. Both of circuits, the efficiency of each stages was calculated and the percentage of error in the front and tail time was also found out as well as the effects of the circuit parameters on the impulse waveform characteristics were also studied. The simulation was done with the help of Pspice Software Simulation. In this work, the comparison in terms of magnitude of the experimental and simulated 10 stages Marx generator circuit has been carried out as well as its illustrative curve has been drawn. These results have confirmed the validity of the proposed method and they were in close agreement.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author .Kh. Eljugmani, Ahmed Saeed
author_facet .Kh. Eljugmani, Ahmed Saeed
author_sort .Kh. Eljugmani, Ahmed Saeed
title Development of portable 10 stages Marx Generator
title_short Development of portable 10 stages Marx Generator
title_full Development of portable 10 stages Marx Generator
title_fullStr Development of portable 10 stages Marx Generator
title_full_unstemmed Development of portable 10 stages Marx Generator
title_sort development of portable 10 stages marx generator
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Faculty of Electrical and Electronics Engineering
publishDate 2015
url http://eprints.uthm.edu.my/1286/2/AHMED%20SAEED%20.KH.%20ELJUGMANI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1286/1/24p%20AHMED%20SAEED%20.KH.%20ELJUGMANI.pdf
http://eprints.uthm.edu.my/1286/3/AHMED%20SAEED%20.KH.%20ELJUGMANI%20WATERMARK.pdf
_version_ 1747830763599953920