Recommended protection scheme setting coordination for nine busbars transmission grid

Protection system is one of the important parts of the power system. The protection system can be accepted if and only if it is efficient, reliable and realizes some requirements. For protection of transmission line three stepped distance protection can provide remote backup protection to transmi...

Full description

Saved in:
Bibliographic Details
Main Author: Saleem, Radhwan Mohammed
Format: Thesis
Language:English
English
English
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/1442/3/RADHWAN%20MOHAMMED%20SALEEM%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1442/1/24p%20RADHWAN%20MOHAMMED%20SALEEM.pdf
http://eprints.uthm.edu.my/1442/2/RADHWAN%20MOHAMMED%20SALEEM%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1442
record_format uketd_dc
spelling my-uthm-ep.14422021-10-03T07:22:24Z Recommended protection scheme setting coordination for nine busbars transmission grid 2015-06 Saleem, Radhwan Mohammed TK3001-3521 Distribution or transmission of electric power Protection system is one of the important parts of the power system. The protection system can be accepted if and only if it is efficient, reliable and realizes some requirements. For protection of transmission line three stepped distance protection can provide remote backup protection to transmission line by zone 2 and zone 3, but during the calculation of operation setting for different protection zones of the distance relays, some problems have been raised (overlap and under reach). These problems cause improper trips in the network. The aims at overcoming the problems are by taking into consideration the specifications of the adjacent transmission lines, the effect of arc resistance, earth resistance and the effect of remote infeed. The line protection schemes are composed of distance relays and directional overcurrent relays where the setting of the relays must be computed considering both relays. Separate relay computation would lead to loss of selectivity. The standard IEC 60255 combined with the considerations of zone 2 tripping time have been used in order to overcome the coordination problems with the main protection (distance protection) as a local protection and to provide remote backup protection to the other overcurrent relays in the grid. In this project, the protection of the transmission lines in typical IEEE, 9- busbars grid has been investigated in detail. The proper settings for both main protection (i.e. distance protection) and backup protection (i.e. overcurrent protection) devices have been determined. MATLAB and ETAP have been used as simulating tools to validate the protection settings techniques of the relays. Three approaches of settings have been used for the mentioned relays. The results show the proper settings of the both relays of the entire project. 2015-06 Thesis http://eprints.uthm.edu.my/1442/ http://eprints.uthm.edu.my/1442/3/RADHWAN%20MOHAMMED%20SALEEM%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/1442/1/24p%20RADHWAN%20MOHAMMED%20SALEEM.pdf text en public http://eprints.uthm.edu.my/1442/2/RADHWAN%20MOHAMMED%20SALEEM%20WATERMARK.pdf text en validuser mphil doctoral Universiti Tun Hussein Onn Malaysia Faculty of Electrical and Electronic Engineering
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TK3001-3521 Distribution or transmission of electric power
spellingShingle TK3001-3521 Distribution or transmission of electric power
Saleem, Radhwan Mohammed
Recommended protection scheme setting coordination for nine busbars transmission grid
description Protection system is one of the important parts of the power system. The protection system can be accepted if and only if it is efficient, reliable and realizes some requirements. For protection of transmission line three stepped distance protection can provide remote backup protection to transmission line by zone 2 and zone 3, but during the calculation of operation setting for different protection zones of the distance relays, some problems have been raised (overlap and under reach). These problems cause improper trips in the network. The aims at overcoming the problems are by taking into consideration the specifications of the adjacent transmission lines, the effect of arc resistance, earth resistance and the effect of remote infeed. The line protection schemes are composed of distance relays and directional overcurrent relays where the setting of the relays must be computed considering both relays. Separate relay computation would lead to loss of selectivity. The standard IEC 60255 combined with the considerations of zone 2 tripping time have been used in order to overcome the coordination problems with the main protection (distance protection) as a local protection and to provide remote backup protection to the other overcurrent relays in the grid. In this project, the protection of the transmission lines in typical IEEE, 9- busbars grid has been investigated in detail. The proper settings for both main protection (i.e. distance protection) and backup protection (i.e. overcurrent protection) devices have been determined. MATLAB and ETAP have been used as simulating tools to validate the protection settings techniques of the relays. Three approaches of settings have been used for the mentioned relays. The results show the proper settings of the both relays of the entire project.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Doctorate
author Saleem, Radhwan Mohammed
author_facet Saleem, Radhwan Mohammed
author_sort Saleem, Radhwan Mohammed
title Recommended protection scheme setting coordination for nine busbars transmission grid
title_short Recommended protection scheme setting coordination for nine busbars transmission grid
title_full Recommended protection scheme setting coordination for nine busbars transmission grid
title_fullStr Recommended protection scheme setting coordination for nine busbars transmission grid
title_full_unstemmed Recommended protection scheme setting coordination for nine busbars transmission grid
title_sort recommended protection scheme setting coordination for nine busbars transmission grid
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Faculty of Electrical and Electronic Engineering
publishDate 2015
url http://eprints.uthm.edu.my/1442/3/RADHWAN%20MOHAMMED%20SALEEM%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1442/1/24p%20RADHWAN%20MOHAMMED%20SALEEM.pdf
http://eprints.uthm.edu.my/1442/2/RADHWAN%20MOHAMMED%20SALEEM%20WATERMARK.pdf
_version_ 1747830790548357120