Fuse blow scheme and its impact on overhead distribution system reliability

Electricity has become a major necessity in the modern world, and the availability has to reach to not only the city area but to the rural areas of population as well. To ensure the electrical distribution system is healthy, protection schemes have to be in place and one such method is the use...

Full description

Saved in:
Bibliographic Details
Main Author: Bajerai, Qaddafi Abdullah
Format: Thesis
Language:English
English
English
Published: 2014
Subjects:
Online Access:http://eprints.uthm.edu.my/1663/1/24p%20QADDAFI%20ABDULLAH%20BAJERAI.pdf
http://eprints.uthm.edu.my/1663/2/QADDAFI%20ABDULLAH%20BAJERAI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1663/3/QADDAFI%20ABDULLAH%20BAJERAI%20WATERMARK.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.1663
record_format uketd_dc
spelling my-uthm-ep.16632021-10-04T08:24:29Z Fuse blow scheme and its impact on overhead distribution system reliability 2014-07 Bajerai, Qaddafi Abdullah TK Electrical engineering. Electronics Nuclear engineering TK1001-1841 Production of electric energy or power. Powerplants. Central stations Electricity has become a major necessity in the modern world, and the availability has to reach to not only the city area but to the rural areas of population as well. To ensure the electrical distribution system is healthy, protection schemes have to be in place and one such method is the use of fuse blow method. This method is extensively used by the electric utility’s distribution system in Sabah and has shown effective protection requirements. However, this comes as a tradeoff to customers experiencing outages of electric supply. The study was carried out to identify the impact of fuse blow method and the accompanying results from actual performance of the overhead distribution system in a selected area, which in this case is the Kota Belud area. Many factors influence the reliability of the system such as the length of the distribution feeders, number of customers in each point of the system and placement of the fuses. The method used was the enumerative analysis to calculate the reliability impact of the fuse blow method. From the calculations, the result is then compared with the actual performance of the system in a one year period. The length of the feeders has the biggest impact to the reliability calculation and this is reflected by the data of actual performance of the feeders. A delicate balance of fusing coordination and limiting of feeder length is needed to ensure that the impact of the fuse blow method to the customer is adequately mitigated. 2014-07 Thesis http://eprints.uthm.edu.my/1663/ http://eprints.uthm.edu.my/1663/1/24p%20QADDAFI%20ABDULLAH%20BAJERAI.pdf text en public http://eprints.uthm.edu.my/1663/2/QADDAFI%20ABDULLAH%20BAJERAI%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/1663/3/QADDAFI%20ABDULLAH%20BAJERAI%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TK Electrical engineering
Electronics Nuclear engineering
TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
TK Electrical engineering
Electronics Nuclear engineering
Bajerai, Qaddafi Abdullah
Fuse blow scheme and its impact on overhead distribution system reliability
description Electricity has become a major necessity in the modern world, and the availability has to reach to not only the city area but to the rural areas of population as well. To ensure the electrical distribution system is healthy, protection schemes have to be in place and one such method is the use of fuse blow method. This method is extensively used by the electric utility’s distribution system in Sabah and has shown effective protection requirements. However, this comes as a tradeoff to customers experiencing outages of electric supply. The study was carried out to identify the impact of fuse blow method and the accompanying results from actual performance of the overhead distribution system in a selected area, which in this case is the Kota Belud area. Many factors influence the reliability of the system such as the length of the distribution feeders, number of customers in each point of the system and placement of the fuses. The method used was the enumerative analysis to calculate the reliability impact of the fuse blow method. From the calculations, the result is then compared with the actual performance of the system in a one year period. The length of the feeders has the biggest impact to the reliability calculation and this is reflected by the data of actual performance of the feeders. A delicate balance of fusing coordination and limiting of feeder length is needed to ensure that the impact of the fuse blow method to the customer is adequately mitigated.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Bajerai, Qaddafi Abdullah
author_facet Bajerai, Qaddafi Abdullah
author_sort Bajerai, Qaddafi Abdullah
title Fuse blow scheme and its impact on overhead distribution system reliability
title_short Fuse blow scheme and its impact on overhead distribution system reliability
title_full Fuse blow scheme and its impact on overhead distribution system reliability
title_fullStr Fuse blow scheme and its impact on overhead distribution system reliability
title_full_unstemmed Fuse blow scheme and its impact on overhead distribution system reliability
title_sort fuse blow scheme and its impact on overhead distribution system reliability
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Elektrik dan Elektronik
publishDate 2014
url http://eprints.uthm.edu.my/1663/1/24p%20QADDAFI%20ABDULLAH%20BAJERAI.pdf
http://eprints.uthm.edu.my/1663/2/QADDAFI%20ABDULLAH%20BAJERAI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1663/3/QADDAFI%20ABDULLAH%20BAJERAI%20WATERMARK.pdf
_version_ 1747830841254346752