Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation
In modern industrial nowadays, electric supply is crucial and brought major impact to economic and new technology development in the country. There are many issues and technical problems occur at distribution system. Voltage sag is one of major problems. In the distribution system, voltage sag can o...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2020
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/389/1/24p%20MOHAMAD%20AMIRUL%20MOHMAD%20AKIL.pdf http://eprints.uthm.edu.my/389/2/MOHAMAD%20AMIRUL%20MOHMAD%20AKIL%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/389/3/MOHAMAD%20AMIRUL%20MOHMAD%20AKIL%20WATERMARK.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uthm-ep.389 |
---|---|
record_format |
uketd_dc |
spelling |
my-uthm-ep.3892021-07-25T01:55:03Z Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation 2020-02 Mohmad Akil, Mohamad Amirul TK1001-1841 Production of electric energy or power. Powerplants. Central stations In modern industrial nowadays, electric supply is crucial and brought major impact to economic and new technology development in the country. There are many issues and technical problems occur at distribution system. Voltage sag is one of major problems. In the distribution system, voltage sag can occur in any point at any time. This issue always brought up for discussion by Electrical power committee all around the world. There are many causes of voltage sag such as overload by consumption area, electrical faults on utility lines, switching operations, trip or short circuit and any single or three phase faults. In order to mitigate this problem, many research and power control have been used. Therefore, this project chooses the Distribution Static Compensator (DSTATCOM) for mitigating voltage sag that happens in power electrical area. Its ability to stabilize power distribution in network system and many useful characteristics is considered. DSTATCOM consists of two voltage level Voltage Source Converter (VSC), DC storage device and a coupling transformer. This project focuses on development of 6-pulses, 12-pulses and 24-pulses DSTATCOM in order to mitigate voltage sag and compared each DSTATCOM results to gain control of power distribution. In order to mitigate voltage sag, the D-STATCOM has been compared in terms of Voltage Per-Unit (Vpu) and reactive power compensations. In the end, the best design is chosen based on capability to mitigate voltage sag with most stable power distribution. It is proven that DSTATCOM able to mitigate voltage sag by injecting current so that voltage sag is back to its rated value. The voltage is restores during fault in order to improve power quality. All simulations results obtained using PSCAD/EMTDC software. By using DSTATCOM, it is able to give harmonic control and provide power quality solutions in utility and industrial applications. 2020-02 Thesis http://eprints.uthm.edu.my/389/ http://eprints.uthm.edu.my/389/1/24p%20MOHAMAD%20AMIRUL%20MOHMAD%20AKIL.pdf text en public http://eprints.uthm.edu.my/389/2/MOHAMAD%20AMIRUL%20MOHMAD%20AKIL%20COPYRIGHT%20DECLARATION.pdf text en staffonly http://eprints.uthm.edu.my/389/3/MOHAMAD%20AMIRUL%20MOHMAD%20AKIL%20WATERMARK.pdf text en validuser mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Elektrik dan Elektronik |
institution |
Universiti Tun Hussein Onn Malaysia |
collection |
UTHM Institutional Repository |
language |
English English English |
topic |
TK1001-1841 Production of electric energy or power Powerplants Central stations |
spellingShingle |
TK1001-1841 Production of electric energy or power Powerplants Central stations Mohmad Akil, Mohamad Amirul Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation |
description |
In modern industrial nowadays, electric supply is crucial and brought major impact to economic and new technology development in the country. There are many issues and technical problems occur at distribution system. Voltage sag is one of major problems. In the distribution system, voltage sag can occur in any point at any time. This issue always brought up for discussion by Electrical power committee all around the world. There are many causes of voltage sag such as overload by consumption area, electrical faults on utility lines, switching operations, trip or short circuit and any single or three phase faults. In order to mitigate this problem, many research and power control have been used. Therefore, this project chooses the Distribution Static Compensator (DSTATCOM) for mitigating voltage sag that happens in power electrical area. Its ability to stabilize power distribution in network system and many useful characteristics is considered. DSTATCOM consists of two voltage level Voltage Source Converter (VSC), DC storage device and a coupling transformer. This project focuses on development of 6-pulses, 12-pulses and 24-pulses DSTATCOM in order to mitigate voltage sag and compared each DSTATCOM results to gain control of power distribution. In order to mitigate voltage sag, the D-STATCOM has been compared in terms of Voltage Per-Unit (Vpu) and reactive power compensations. In the end, the best design is chosen based on capability to mitigate voltage sag with most stable power distribution. It is proven that DSTATCOM able to mitigate voltage sag by injecting current so that voltage sag is back to its rated value. The voltage is restores during fault in order to improve power quality. All simulations results obtained using PSCAD/EMTDC software. By using DSTATCOM, it is able to give harmonic control and provide power quality solutions in utility and industrial applications. |
format |
Thesis |
qualification_name |
Master of Philosophy (M.Phil.) |
qualification_level |
Master's degree |
author |
Mohmad Akil, Mohamad Amirul |
author_facet |
Mohmad Akil, Mohamad Amirul |
author_sort |
Mohmad Akil, Mohamad Amirul |
title |
Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation |
title_short |
Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation |
title_full |
Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation |
title_fullStr |
Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation |
title_full_unstemmed |
Study on 6, 12 and 24 pulses D-STATCOM for voltage SAG mitigation |
title_sort |
study on 6, 12 and 24 pulses d-statcom for voltage sag mitigation |
granting_institution |
Universiti Tun Hussein Onn Malaysia |
granting_department |
Fakulti Kejuruteraan Elektrik dan Elektronik |
publishDate |
2020 |
url |
http://eprints.uthm.edu.my/389/1/24p%20MOHAMAD%20AMIRUL%20MOHMAD%20AKIL.pdf http://eprints.uthm.edu.my/389/2/MOHAMAD%20AMIRUL%20MOHMAD%20AKIL%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/389/3/MOHAMAD%20AMIRUL%20MOHMAD%20AKIL%20WATERMARK.pdf |
_version_ |
1747830598658949120 |