Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters

By the rapid of urban growth, it is impossible to accommodate the number and size of feeder required for distribution using the overhead line system approach. As an alternative the underground cables becomes more increasingly necessary to replace some of the overhead line for power transmissio...

Full description

Saved in:
Bibliographic Details
Main Author: Ponniran, Asmarashid
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.uthm.edu.my/7608/1/ASMARASHID%20PONNIRAN%20COPYRIGHT%20DECLARATION.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.7608
record_format uketd_dc
spelling my-uthm-ep.76082022-08-29T07:37:33Z Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters 2005-03 Ponniran, Asmarashid TK Electrical engineering. Electronics Nuclear engineering TK3001-3521 Distribution or transmission of electric power By the rapid of urban growth, it is impossible to accommodate the number and size of feeder required for distribution using the overhead line system approach. As an alternative the underground cables becomes more increasingly necessary to replace some of the overhead line for power transmission and distribution. Because of that reason, underground XLPE cables are the most popular for the underground systems. Performance of underground cables in service is being critical because of ageing mechanisms influences. There are many suitable techniques can be used to evaluate performance of aged and unaged underground cables. One of the techniques is based on tan delta and capacitance parameters of underground cables. This study only focuses on underground XLPE cables, which are voltage rated atl lkV and 22kV for 1-core and 3-cores types. By using Tettex Instruments — Schering Bridge Model 2816, tan delta and capacitance data of XLPE underground cables are obtained. Tan delta and capacitance measurements were performed at ambient temperature (26.6°C) and at power frequency (50 Hz). From these analyses, show that tan delta values will be increased proportional with aging time of cables in service. Aging mechanisms are contributes these deteriorations of cables in service and consequently values of tan delta are increased with aging time of cable. Meanwhile, form capacitance analysis, the values of capacitance will be increased when contaminants, protrusions and voids are affected cables insulation and when moisture enters inside underground cable systems. 2005-03 Thesis http://eprints.uthm.edu.my/7608/ http://eprints.uthm.edu.my/7608/1/ASMARASHID%20PONNIRAN%20COPYRIGHT%20DECLARATION.pdf text en public mphil masters Universiti Teknologi Malaysia Fakulti Kejuruteraan Elektrik
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
TK3001-3521 Distribution or transmission of electric power
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
TK3001-3521 Distribution or transmission of electric power
Ponniran, Asmarashid
Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters
description By the rapid of urban growth, it is impossible to accommodate the number and size of feeder required for distribution using the overhead line system approach. As an alternative the underground cables becomes more increasingly necessary to replace some of the overhead line for power transmission and distribution. Because of that reason, underground XLPE cables are the most popular for the underground systems. Performance of underground cables in service is being critical because of ageing mechanisms influences. There are many suitable techniques can be used to evaluate performance of aged and unaged underground cables. One of the techniques is based on tan delta and capacitance parameters of underground cables. This study only focuses on underground XLPE cables, which are voltage rated atl lkV and 22kV for 1-core and 3-cores types. By using Tettex Instruments — Schering Bridge Model 2816, tan delta and capacitance data of XLPE underground cables are obtained. Tan delta and capacitance measurements were performed at ambient temperature (26.6°C) and at power frequency (50 Hz). From these analyses, show that tan delta values will be increased proportional with aging time of cables in service. Aging mechanisms are contributes these deteriorations of cables in service and consequently values of tan delta are increased with aging time of cable. Meanwhile, form capacitance analysis, the values of capacitance will be increased when contaminants, protrusions and voids are affected cables insulation and when moisture enters inside underground cable systems.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Ponniran, Asmarashid
author_facet Ponniran, Asmarashid
author_sort Ponniran, Asmarashid
title Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters
title_short Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters
title_full Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters
title_fullStr Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters
title_full_unstemmed Study on the performance of underground XPLE cables in service based on Tan Delta and capacitance parameters
title_sort study on the performance of underground xple cables in service based on tan delta and capacitance parameters
granting_institution Universiti Teknologi Malaysia
granting_department Fakulti Kejuruteraan Elektrik
publishDate 2005
url http://eprints.uthm.edu.my/7608/1/ASMARASHID%20PONNIRAN%20COPYRIGHT%20DECLARATION.pdf
_version_ 1747831169519452160