Humidity control in different building applications; restaurant and operation theatre

Air conditioning (AC) in tropical climate required dehumidification of air at a low dew point temperature to meet humidity standard. This increase the required cooling energy and heating energy is needed to raise the supply air temperature to meet the room’s design temperature. This research was car...

Full description

Saved in:
Bibliographic Details
Main Author: Mustafa, Mohd Syafiq Syazwan
Format: Thesis
Language:English
English
English
Published: 2017
Subjects:
Online Access:http://eprints.uthm.edu.my/804/1/24p%20MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA.pdf
http://eprints.uthm.edu.my/804/2/MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA%20WATERMARK.pdf
http://eprints.uthm.edu.my/804/3/MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA%20COPYRIGHT%20DECLARATION.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uthm-ep.804
record_format uketd_dc
spelling my-uthm-ep.8042021-09-01T07:54:19Z Humidity control in different building applications; restaurant and operation theatre 2017-04 Mustafa, Mohd Syafiq Syazwan TH7005-7699 Heating and ventilation. Air conditioning Air conditioning (AC) in tropical climate required dehumidification of air at a low dew point temperature to meet humidity standard. This increase the required cooling energy and heating energy is needed to raise the supply air temperature to meet the room’s design temperature. This research was carried out to study energy efficiency and indoor environment factor in two different applications that is restaurant and operation theatre (OT). A method was proposed to enhance the humidity control and energy efficiency in the AC system by applying psychrometric analysis based on actual measurement. Three (3) different systems were used in this study that consists of economizer damper, desiccant wheel and heat pipe heat exchanger (HPHX).The economizer damper analysed base on fresh air intake requirement for ventilation purposes on standard ASHRAE 55 (2010). Manufacturing software by Novelaire and HPC were used to perform the psychorometric analysis for desiccant wheel and HPHX. At the restaurant, the grand total loads (Qt) of the existing AC system were 296.1 kW as to meet temperature and humidity level requirement. The Qt was reduced to 153.8 kW for economizer damper, 170 kW with heating 60.38 kW for desiccant wheel and 178.3 kW with heating 4.1 kW for HPHX. In actual measurement for the OT, the existing AC system had a grand total load Qt of 90.1 kW with heating 5.6 kW and it did not meet the humidity level requirement. However, the AC system required Qt 95.9 kW with heating 12.2 kW as to meet the humidity level requirement for an OT. By using the HPHX in the system, a reduced Qt of 81.6 kW with heating 17.7 kW was achieved, where as a Qt of 100.8 kW with heating 39.9 kW was attained by utilizing the desiccant wheel, whilst maintaining the humidity level requirement. The economizer damper was not applicable for the OT because the OT requires 100% fresh air intake. As a conclusion, damper economizer was beneficial for energy efficiency in restaurants with reducing of 48% energy used and HPHX was beneficial for energy efficiency with reduced 9.4% in OT compared with existing AC system. 2017-04 Thesis http://eprints.uthm.edu.my/804/ http://eprints.uthm.edu.my/804/1/24p%20MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA.pdf text en public http://eprints.uthm.edu.my/804/2/MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA%20WATERMARK.pdf text en validuser http://eprints.uthm.edu.my/804/3/MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA%20COPYRIGHT%20DECLARATION.pdf text en staffonly mphil masters Universiti Tun Hussein Onn Malaysia Fakulti Kejuruteraan Mekanikal dan Pembuatan
institution Universiti Tun Hussein Onn Malaysia
collection UTHM Institutional Repository
language English
English
English
topic TH7005-7699 Heating and ventilation
Air conditioning
spellingShingle TH7005-7699 Heating and ventilation
Air conditioning
Mustafa, Mohd Syafiq Syazwan
Humidity control in different building applications; restaurant and operation theatre
description Air conditioning (AC) in tropical climate required dehumidification of air at a low dew point temperature to meet humidity standard. This increase the required cooling energy and heating energy is needed to raise the supply air temperature to meet the room’s design temperature. This research was carried out to study energy efficiency and indoor environment factor in two different applications that is restaurant and operation theatre (OT). A method was proposed to enhance the humidity control and energy efficiency in the AC system by applying psychrometric analysis based on actual measurement. Three (3) different systems were used in this study that consists of economizer damper, desiccant wheel and heat pipe heat exchanger (HPHX).The economizer damper analysed base on fresh air intake requirement for ventilation purposes on standard ASHRAE 55 (2010). Manufacturing software by Novelaire and HPC were used to perform the psychorometric analysis for desiccant wheel and HPHX. At the restaurant, the grand total loads (Qt) of the existing AC system were 296.1 kW as to meet temperature and humidity level requirement. The Qt was reduced to 153.8 kW for economizer damper, 170 kW with heating 60.38 kW for desiccant wheel and 178.3 kW with heating 4.1 kW for HPHX. In actual measurement for the OT, the existing AC system had a grand total load Qt of 90.1 kW with heating 5.6 kW and it did not meet the humidity level requirement. However, the AC system required Qt 95.9 kW with heating 12.2 kW as to meet the humidity level requirement for an OT. By using the HPHX in the system, a reduced Qt of 81.6 kW with heating 17.7 kW was achieved, where as a Qt of 100.8 kW with heating 39.9 kW was attained by utilizing the desiccant wheel, whilst maintaining the humidity level requirement. The economizer damper was not applicable for the OT because the OT requires 100% fresh air intake. As a conclusion, damper economizer was beneficial for energy efficiency in restaurants with reducing of 48% energy used and HPHX was beneficial for energy efficiency with reduced 9.4% in OT compared with existing AC system.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Mustafa, Mohd Syafiq Syazwan
author_facet Mustafa, Mohd Syafiq Syazwan
author_sort Mustafa, Mohd Syafiq Syazwan
title Humidity control in different building applications; restaurant and operation theatre
title_short Humidity control in different building applications; restaurant and operation theatre
title_full Humidity control in different building applications; restaurant and operation theatre
title_fullStr Humidity control in different building applications; restaurant and operation theatre
title_full_unstemmed Humidity control in different building applications; restaurant and operation theatre
title_sort humidity control in different building applications; restaurant and operation theatre
granting_institution Universiti Tun Hussein Onn Malaysia
granting_department Fakulti Kejuruteraan Mekanikal dan Pembuatan
publishDate 2017
url http://eprints.uthm.edu.my/804/1/24p%20MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA.pdf
http://eprints.uthm.edu.my/804/2/MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA%20WATERMARK.pdf
http://eprints.uthm.edu.my/804/3/MOHD%20SYAFIQ%20SYAZWAN%20MUSTAFA%20COPYRIGHT%20DECLARATION.pdf
_version_ 1747830685373038592