Performance of pullout resistance of anchored earth system by field pullout test

Anchored Earth System had been developed from combination of the techniques used in reinforced earth and soil anchoring. Instead of using steel strip as a reinforcement, Anchored Earth System consist of round steel bar (tendon) with precast concrete block attached at the free end of each of the rein...

Full description

Saved in:
Bibliographic Details
Main Author: Loh, Wee Loon
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.utm.my/id/eprint/10626/6/LohWeeLoonMFKA2010.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.10626
record_format uketd_dc
spelling my-utm-ep.106262017-09-28T00:25:29Z Performance of pullout resistance of anchored earth system by field pullout test 2010-03 Loh, Wee Loon TA Engineering (General). Civil engineering (General) Anchored Earth System had been developed from combination of the techniques used in reinforced earth and soil anchoring. Instead of using steel strip as a reinforcement, Anchored Earth System consist of round steel bar (tendon) with precast concrete block attached at the free end of each of the reinforcing steel bars, and it is backfilled with granular material or suitable earth fill. This research project can be considered a case study of anchored reinforced soil wall which investigates the performance of Anchored Earth System due to its pullout capacity. In this study, pullout resistance which contributed by friction between the backfill material and the shaft surface of reinforcing tendon, and the passive earth pressure against the concrete anchor block, can be evaluated through pullout tests. The main problems to be studied in this project are the results obtained from field pullout test are different from the calculated theoretical values and there is a non-zero intercept at relationship of pullout force against overburden pressure. The field pullout tests were carried out in three conditions: i) with reinforcing tendon only; ii) with anchor block only; and iii) with both reinforcing tendon and anchor block together in order to determine the sharing of resistance in the system. The pullout test was also done under soaked condition. The average interaction coefficient a’ = 1.99 and bearing factor ß = 6.32 were determined by back analysis. It was found that the sharing of load between the tendon and the anchor block in anchored earth system is not equal, but most of the resistance is contributed by the bearing passive of anchor block where approximately 30 % of resistance contributed by residual frictional resistance and 70 % contributed by peak bearing passive resistance. The pullout resistance in soaked condition observed to be lower than in unsoaked condition due to the increase in pore water pressure that reduced the shear resistance. 2010-03 Thesis http://eprints.utm.my/id/eprint/10626/ http://eprints.utm.my/id/eprint/10626/6/LohWeeLoonMFKA2010.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Loh, Wee Loon
Performance of pullout resistance of anchored earth system by field pullout test
description Anchored Earth System had been developed from combination of the techniques used in reinforced earth and soil anchoring. Instead of using steel strip as a reinforcement, Anchored Earth System consist of round steel bar (tendon) with precast concrete block attached at the free end of each of the reinforcing steel bars, and it is backfilled with granular material or suitable earth fill. This research project can be considered a case study of anchored reinforced soil wall which investigates the performance of Anchored Earth System due to its pullout capacity. In this study, pullout resistance which contributed by friction between the backfill material and the shaft surface of reinforcing tendon, and the passive earth pressure against the concrete anchor block, can be evaluated through pullout tests. The main problems to be studied in this project are the results obtained from field pullout test are different from the calculated theoretical values and there is a non-zero intercept at relationship of pullout force against overburden pressure. The field pullout tests were carried out in three conditions: i) with reinforcing tendon only; ii) with anchor block only; and iii) with both reinforcing tendon and anchor block together in order to determine the sharing of resistance in the system. The pullout test was also done under soaked condition. The average interaction coefficient a’ = 1.99 and bearing factor ß = 6.32 were determined by back analysis. It was found that the sharing of load between the tendon and the anchor block in anchored earth system is not equal, but most of the resistance is contributed by the bearing passive of anchor block where approximately 30 % of resistance contributed by residual frictional resistance and 70 % contributed by peak bearing passive resistance. The pullout resistance in soaked condition observed to be lower than in unsoaked condition due to the increase in pore water pressure that reduced the shear resistance.
format Thesis
qualification_level Master's degree
author Loh, Wee Loon
author_facet Loh, Wee Loon
author_sort Loh, Wee Loon
title Performance of pullout resistance of anchored earth system by field pullout test
title_short Performance of pullout resistance of anchored earth system by field pullout test
title_full Performance of pullout resistance of anchored earth system by field pullout test
title_fullStr Performance of pullout resistance of anchored earth system by field pullout test
title_full_unstemmed Performance of pullout resistance of anchored earth system by field pullout test
title_sort performance of pullout resistance of anchored earth system by field pullout test
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2010
url http://eprints.utm.my/id/eprint/10626/6/LohWeeLoonMFKA2010.pdf
_version_ 1747814798622457856