Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper

In structural earthquake engineering, different kinds of energy absorption devices were invented during last 30 years (Guan et al, 2004). And more than one-decade research has shown that, on account of the virtue of no power requirement, rapid response and coulomb friction principle of friction damp...

Full description

Saved in:
Bibliographic Details
Main Author: Ong, Peng Pheng
Format: Thesis
Language:English
Published: 2009
Subjects:
Online Access:http://eprints.utm.my/id/eprint/11125/1/OngPengPhengMFKA2009.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.11125
record_format uketd_dc
spelling my-utm-ep.111252018-06-04T09:51:22Z Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper 2009-06 Ong, Peng Pheng TA Engineering (General). Civil engineering (General) In structural earthquake engineering, different kinds of energy absorption devices were invented during last 30 years (Guan et al, 2004). And more than one-decade research has shown that, on account of the virtue of no power requirement, rapid response and coulomb friction principle of friction damper is one of best of them. It is used as plating friction for energy dissipation systems to reduce earthquake effect on structures. With laminated steel plates and bolt, the friction damper can provide high diagonal stiffness and flexibility in horizontal direction to ensure the mounting forces can be supported by the stresses induced on the structure and prevent excessive sideways from any horizontal loading especially when earthquake occur. This research is to study the performance of Air Traffic Control Tower of Kuala Lumpur International Airport (KLIA Control Tower) under low intensity earthquake effect of induced earthquake acceleration of 0.19g. The finite element modelling technique is used in this study to learn the behaviour of friction damper and vulnerability of loading from vertical and horizontal directions with the proposed application. Performances of the friction damper were examined based on their percentile capacity passing and inter-storey drift displacement, consisting of Beam Models and Shell Models with and without friction damper. Friction damper is designed within the lift-core and it is found that the usage of designed retrofitted friction damper increases the overall performance of the KLIA Control Tower. In general, this study indicates that the seismic risks should be considered in designing the tower for Malaysia construction and the application of the seismic retrofitting to this existing building is much needed to safeguard structure from external peak ground acceleration intensity. Therefore, it is discovered from the final analysis the friction damper is able to stiffen the structure from seismic loading in term of deformation and axial force from the intensity of 019g, 0.29g and 0.39g. 2009-06 Thesis http://eprints.utm.my/id/eprint/11125/ http://eprints.utm.my/id/eprint/11125/1/OngPengPhengMFKA2009.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Ong, Peng Pheng
Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper
description In structural earthquake engineering, different kinds of energy absorption devices were invented during last 30 years (Guan et al, 2004). And more than one-decade research has shown that, on account of the virtue of no power requirement, rapid response and coulomb friction principle of friction damper is one of best of them. It is used as plating friction for energy dissipation systems to reduce earthquake effect on structures. With laminated steel plates and bolt, the friction damper can provide high diagonal stiffness and flexibility in horizontal direction to ensure the mounting forces can be supported by the stresses induced on the structure and prevent excessive sideways from any horizontal loading especially when earthquake occur. This research is to study the performance of Air Traffic Control Tower of Kuala Lumpur International Airport (KLIA Control Tower) under low intensity earthquake effect of induced earthquake acceleration of 0.19g. The finite element modelling technique is used in this study to learn the behaviour of friction damper and vulnerability of loading from vertical and horizontal directions with the proposed application. Performances of the friction damper were examined based on their percentile capacity passing and inter-storey drift displacement, consisting of Beam Models and Shell Models with and without friction damper. Friction damper is designed within the lift-core and it is found that the usage of designed retrofitted friction damper increases the overall performance of the KLIA Control Tower. In general, this study indicates that the seismic risks should be considered in designing the tower for Malaysia construction and the application of the seismic retrofitting to this existing building is much needed to safeguard structure from external peak ground acceleration intensity. Therefore, it is discovered from the final analysis the friction damper is able to stiffen the structure from seismic loading in term of deformation and axial force from the intensity of 019g, 0.29g and 0.39g.
format Thesis
qualification_level Master's degree
author Ong, Peng Pheng
author_facet Ong, Peng Pheng
author_sort Ong, Peng Pheng
title Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper
title_short Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper
title_full Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper
title_fullStr Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper
title_full_unstemmed Seismic performance analysis of Kuala Lumpur air traffic control tower by friction damper
title_sort seismic performance analysis of kuala lumpur air traffic control tower by friction damper
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2009
url http://eprints.utm.my/id/eprint/11125/1/OngPengPhengMFKA2009.pdf
_version_ 1747814815571640320