Electrocoagulation for suspended solid removal in domestic wastewater treatment

The treatment of wastewater has become an absolute necessity. Innovative, cheap and effective methods of purifying and cleaning wastewater before discharging into any other water systems are needed. A wide range of wastewater treatment techniques are known which include biological processes and phys...

Full description

Saved in:
Bibliographic Details
Main Author: Rahmalan, Muhammad Taufiq
Format: Thesis
Language:English
Published: 2009
Subjects:
Online Access:http://eprints.utm.my/id/eprint/11997/6/MuhammadTaufiqRahmalanMFKA2009.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.11997
record_format uketd_dc
spelling my-utm-ep.119972017-09-18T11:35:46Z Electrocoagulation for suspended solid removal in domestic wastewater treatment 2009-11 Rahmalan, Muhammad Taufiq TA Engineering (General). Civil engineering (General) The treatment of wastewater has become an absolute necessity. Innovative, cheap and effective methods of purifying and cleaning wastewater before discharging into any other water systems are needed. A wide range of wastewater treatment techniques are known which include biological processes and physicochemical processes. A host of promising techniques based on electrochemical technology are being developed and existing ones are improved that require less chemical additions. The present study was conducted to investigate the applicability of the electrocoagulation technique for the treatment of domestic wastewater at the UTM Oxidation Pond effluent as a case study. The combination effects of current, pH and treatment time to the efficiency of the electrocoagulation process for the removal of suspended solids from the domestic wastewater showed that only current(C) and treatment time (t) have correlation with each other. The optimum batch technique operational conditions for the electrocoagulation application to remove suspended solids from domestic wastewater is current value is 0.5A – 0.65A within 46 until 60 minutes treatment time. These optimum conditions have an optimum result with 120 minutes settling time. Meanwhile the optimum conditions for batch technique were applied to the continuous flow method while resulted in between 80-83% efficiencies of suspended solid removal from the wastewater. 2009-11 Thesis http://eprints.utm.my/id/eprint/11997/ http://eprints.utm.my/id/eprint/11997/6/MuhammadTaufiqRahmalanMFKA2009.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Rahmalan, Muhammad Taufiq
Electrocoagulation for suspended solid removal in domestic wastewater treatment
description The treatment of wastewater has become an absolute necessity. Innovative, cheap and effective methods of purifying and cleaning wastewater before discharging into any other water systems are needed. A wide range of wastewater treatment techniques are known which include biological processes and physicochemical processes. A host of promising techniques based on electrochemical technology are being developed and existing ones are improved that require less chemical additions. The present study was conducted to investigate the applicability of the electrocoagulation technique for the treatment of domestic wastewater at the UTM Oxidation Pond effluent as a case study. The combination effects of current, pH and treatment time to the efficiency of the electrocoagulation process for the removal of suspended solids from the domestic wastewater showed that only current(C) and treatment time (t) have correlation with each other. The optimum batch technique operational conditions for the electrocoagulation application to remove suspended solids from domestic wastewater is current value is 0.5A – 0.65A within 46 until 60 minutes treatment time. These optimum conditions have an optimum result with 120 minutes settling time. Meanwhile the optimum conditions for batch technique were applied to the continuous flow method while resulted in between 80-83% efficiencies of suspended solid removal from the wastewater.
format Thesis
qualification_level Master's degree
author Rahmalan, Muhammad Taufiq
author_facet Rahmalan, Muhammad Taufiq
author_sort Rahmalan, Muhammad Taufiq
title Electrocoagulation for suspended solid removal in domestic wastewater treatment
title_short Electrocoagulation for suspended solid removal in domestic wastewater treatment
title_full Electrocoagulation for suspended solid removal in domestic wastewater treatment
title_fullStr Electrocoagulation for suspended solid removal in domestic wastewater treatment
title_full_unstemmed Electrocoagulation for suspended solid removal in domestic wastewater treatment
title_sort electrocoagulation for suspended solid removal in domestic wastewater treatment
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2009
url http://eprints.utm.my/id/eprint/11997/6/MuhammadTaufiqRahmalanMFKA2009.pdf
_version_ 1747814884141170688