Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections

The application of cold-formed steel in light steel framing design can become a popular choice of Industrialized Building System (IBS), by extending the steelwork design into residential housing. However there is a lack of in-depth study on the joints behaviour for primary structures, particularly t...

Full description

Saved in:
Bibliographic Details
Main Author: Tan, Cher Siang
Format: Thesis
Language:English
Published: 2009
Subjects:
Online Access:http://eprints.utm.my/id/eprint/13577/1/TanCherSiangPFKA2009.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.13577
record_format uketd_dc
spelling my-utm-ep.135772018-06-26T07:50:26Z Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections 2009 Tan, Cher Siang TA Engineering (General). Civil engineering (General) The application of cold-formed steel in light steel framing design can become a popular choice of Industrialized Building System (IBS), by extending the steelwork design into residential housing. However there is a lack of in-depth study on the joints behaviour for primary structures, particularly the beam-to-column connection. The objectives of this research are to develop the design procedures of bolted beamto- column connections for double channel cold-formed steel sections, to study the pin and partial strength behaviour of the developed connections based on their strength and stiffness performance, and to validate the performance of the proposed connection configurations by comparing the analytical calculation to experimental results. Analytical study was carried out to develop design procedures for five types of joint methods, namely double angle web-cleats (J1-WC), top-seat flange-cleats (J2-FC), combined flange-web-cleats (J3-FWC), gusset plates (J4-HG) and combined gusset plate flange-cleats (J5-HGFC) to form bolted connections to accommodate members in practical orientations. A series of full scale experimental investigation comprised of twenty-four isolated joint tests and twelve subassemblage frame tests have been carried out to understand the connections’ strength and stiffness behaviour. The experimental results showed good agreement compared to theoretical prediction. From the experimental and analytical results, J1-WC, J2- FC and J3-FWC connections were classified as pin joints, with the strength less than 25% of beam capacity; while J4-HG and J5-HGFC connections were classified as partial strength joints with moment resistance of joint in the range of 46% to 96% to the moment resistance of the connected beam. It was concluded that among the five types of proposed connections, J1-WC, J2-FC and J3-FWC connections were designed as pin joint, J4-HG and J5-HGFC connections were validated to be used as partial strength joints. 2009 Thesis http://eprints.utm.my/id/eprint/13577/ http://eprints.utm.my/id/eprint/13577/1/TanCherSiangPFKA2009.pdf application/pdf en public phd doctoral Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Tan, Cher Siang
Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
description The application of cold-formed steel in light steel framing design can become a popular choice of Industrialized Building System (IBS), by extending the steelwork design into residential housing. However there is a lack of in-depth study on the joints behaviour for primary structures, particularly the beam-to-column connection. The objectives of this research are to develop the design procedures of bolted beamto- column connections for double channel cold-formed steel sections, to study the pin and partial strength behaviour of the developed connections based on their strength and stiffness performance, and to validate the performance of the proposed connection configurations by comparing the analytical calculation to experimental results. Analytical study was carried out to develop design procedures for five types of joint methods, namely double angle web-cleats (J1-WC), top-seat flange-cleats (J2-FC), combined flange-web-cleats (J3-FWC), gusset plates (J4-HG) and combined gusset plate flange-cleats (J5-HGFC) to form bolted connections to accommodate members in practical orientations. A series of full scale experimental investigation comprised of twenty-four isolated joint tests and twelve subassemblage frame tests have been carried out to understand the connections’ strength and stiffness behaviour. The experimental results showed good agreement compared to theoretical prediction. From the experimental and analytical results, J1-WC, J2- FC and J3-FWC connections were classified as pin joints, with the strength less than 25% of beam capacity; while J4-HG and J5-HGFC connections were classified as partial strength joints with moment resistance of joint in the range of 46% to 96% to the moment resistance of the connected beam. It was concluded that among the five types of proposed connections, J1-WC, J2-FC and J3-FWC connections were designed as pin joint, J4-HG and J5-HGFC connections were validated to be used as partial strength joints.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Tan, Cher Siang
author_facet Tan, Cher Siang
author_sort Tan, Cher Siang
title Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
title_short Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
title_full Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
title_fullStr Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
title_full_unstemmed Behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
title_sort behaviour of pin partial strenght beam-to-column connections with double channel cold-formed steel sections
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2009
url http://eprints.utm.my/id/eprint/13577/1/TanCherSiangPFKA2009.pdf
_version_ 1747814961487282176