Image reconstruction of small objects detected by four projection charge coupled device
Analysis on particle size and shape has become a crucial aspect especially in medical imaging and for on-line production control and because these factors influence the product quality and critical to human lives. Moreover, imaging of the particle size and shape generated from on-line measurement ca...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Published: |
2010
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utm-ep.26783 |
---|---|
record_format |
uketd_dc |
spelling |
my-utm-ep.267832017-08-16T03:50:25Z Image reconstruction of small objects detected by four projection charge coupled device 2010 Mohd. Zahid, Noor Sarena TK Electrical engineering. Electronics Nuclear engineering Analysis on particle size and shape has become a crucial aspect especially in medical imaging and for on-line production control and because these factors influence the product quality and critical to human lives. Moreover, imaging of the particle size and shape generated from on-line measurement can provide greater insight into the process itself. Image reconstruction process for the Charge Coupled Device (CCD)- based optical tomography with four projections is discussed in this report. The high resolution CCD linear image sensor used in this project has 2048 pixels with a pixel size of 14 micron by 14 micron. The Sensitivity Matrix of attenuation coefficient up to 2048 pixel is created using C program. A simulation data from the experimental circuit will be tested on Matlab software to produce 2D images. The main algorithm involves to produce the 2D images is Linear Back Projection. 2010 Thesis http://eprints.utm.my/id/eprint/26783/ http://libraryopac.utm.my/client/en_AU/main/search/results?qu=Image+reconstruction+of+small+objects+detected+by+four+projection+charge+coupled+device&te= masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Civil Engineering |
institution |
Universiti Teknologi Malaysia |
collection |
UTM Institutional Repository |
topic |
TK Electrical engineering Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering Electronics Nuclear engineering Mohd. Zahid, Noor Sarena Image reconstruction of small objects detected by four projection charge coupled device |
description |
Analysis on particle size and shape has become a crucial aspect especially in medical imaging and for on-line production control and because these factors influence the product quality and critical to human lives. Moreover, imaging of the particle size and shape generated from on-line measurement can provide greater insight into the process itself. Image reconstruction process for the Charge Coupled Device (CCD)- based optical tomography with four projections is discussed in this report. The high resolution CCD linear image sensor used in this project has 2048 pixels with a pixel size of 14 micron by 14 micron. The Sensitivity Matrix of attenuation coefficient up to 2048 pixel is created using C program. A simulation data from the experimental circuit will be tested on Matlab software to produce 2D images. The main algorithm involves to produce the 2D images is Linear Back Projection. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Mohd. Zahid, Noor Sarena |
author_facet |
Mohd. Zahid, Noor Sarena |
author_sort |
Mohd. Zahid, Noor Sarena |
title |
Image reconstruction of small objects detected by four projection charge coupled device |
title_short |
Image reconstruction of small objects detected by four projection charge coupled device |
title_full |
Image reconstruction of small objects detected by four projection charge coupled device |
title_fullStr |
Image reconstruction of small objects detected by four projection charge coupled device |
title_full_unstemmed |
Image reconstruction of small objects detected by four projection charge coupled device |
title_sort |
image reconstruction of small objects detected by four projection charge coupled device |
granting_institution |
Universiti Teknologi Malaysia, Faculty of Electrical Engineering |
granting_department |
Faculty of Civil Engineering |
publishDate |
2010 |
_version_ |
1747815509812838400 |