Optimization of automatic controller design coefficients
Classical tuning methods of PID controller, such as the Ziegler-Nichols and Cohen-Coon tuning formulae are able to tune the mentioned controller easily, when they use for controlling the linear system. But, empirical studies have found that these conventional tuning methods result in an unsatisfacto...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Published: |
2010
|
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-utm-ep.26890 |
---|---|
record_format |
uketd_dc |
spelling |
my-utm-ep.268902017-08-15T01:34:15Z Optimization of automatic controller design coefficients 2010 Marzoughi, Ali TK Electrical engineering. Electronics Nuclear engineering Classical tuning methods of PID controller, such as the Ziegler-Nichols and Cohen-Coon tuning formulae are able to tune the mentioned controller easily, when they use for controlling the linear system. But, empirical studies have found that these conventional tuning methods result in an unsatisfactory control performance when they are used for processes experiencing the negative destabilizing effects of strong nonlinearities. It is for this reason that control practitioners often prefer to tune most nonlinear systems using trial and error tuning, or intuitive tuning. A need therefore exists for the development of a suitable tuning technique that is applicable for a wide range of control loops that do not respond satisfactorily to conventional tuning. Particle swarm which is developed by Eberhart and Kennedy (1995), have been utilized to solve many non-linear engineering problems. The Particle Swarm Optimization is the method which is implemented to tune the PID controller to control the exhaust temperature of gas turbine, model M5001. The result is compared to the conventional PID controller using Ziegler-Nichols method. Mathematical model of the exhaust temperature of mentioned gas turbine was extracted from simplified mathematical model which is developed by W.I.Rowen (1983). As it will be discussed in conclusion, simulation result illustrate that using PSO, to tune the PID controller improves the important parameters of the system such as, maximum overshoot, rise time and settling time and reduces the error rather than conventional tuning method such as Ziegler-Nichols technique. 2010 Thesis http://eprints.utm.my/id/eprint/26890/ http://libraryopac.utm.my/client/en_AU/main/search/results?qu=Optimization+of+automatic+controller+design+coefficients&te= masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering |
institution |
Universiti Teknologi Malaysia |
collection |
UTM Institutional Repository |
topic |
TK Electrical engineering Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering Electronics Nuclear engineering Marzoughi, Ali Optimization of automatic controller design coefficients |
description |
Classical tuning methods of PID controller, such as the Ziegler-Nichols and Cohen-Coon tuning formulae are able to tune the mentioned controller easily, when they use for controlling the linear system. But, empirical studies have found that these conventional tuning methods result in an unsatisfactory control performance when they are used for processes experiencing the negative destabilizing effects of strong nonlinearities. It is for this reason that control practitioners often prefer to tune most nonlinear systems using trial and error tuning, or intuitive tuning. A need therefore exists for the development of a suitable tuning technique that is applicable for a wide range of control loops that do not respond satisfactorily to conventional tuning. Particle swarm which is developed by Eberhart and Kennedy (1995), have been utilized to solve many non-linear engineering problems. The Particle Swarm Optimization is the method which is implemented to tune the PID controller to control the exhaust temperature of gas turbine, model M5001. The result is compared to the conventional PID controller using Ziegler-Nichols method. Mathematical model of the exhaust temperature of mentioned gas turbine was extracted from simplified mathematical model which is developed by W.I.Rowen (1983). As it will be discussed in conclusion, simulation result illustrate that using PSO, to tune the PID controller improves the important parameters of the system such as, maximum overshoot, rise time and settling time and reduces the error rather than conventional tuning method such as Ziegler-Nichols technique. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Marzoughi, Ali |
author_facet |
Marzoughi, Ali |
author_sort |
Marzoughi, Ali |
title |
Optimization of automatic controller design coefficients |
title_short |
Optimization of automatic controller design coefficients |
title_full |
Optimization of automatic controller design coefficients |
title_fullStr |
Optimization of automatic controller design coefficients |
title_full_unstemmed |
Optimization of automatic controller design coefficients |
title_sort |
optimization of automatic controller design coefficients |
granting_institution |
Universiti Teknologi Malaysia, Faculty of Electrical Engineering |
granting_department |
Faculty of Electrical Engineering |
publishDate |
2010 |
_version_ |
1747815535728394240 |