Finite element analysis of prestressed concrete box girder bridge

Curved concrete bridge girders have very complex internal forces, stress and strain distribution. As a consequence of their shape, not only the usual bending moments and shear forces are generated, but also important torsion moments are created. These moments rotate the axes of principal tensional s...

Full description

Saved in:
Bibliographic Details
Main Author: Othman, Rebaz Abdulghafoor
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.utm.my/id/eprint/40553/5/RebazAbdulghafoorOthmanMFKA2013.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.40553
record_format uketd_dc
spelling my-utm-ep.405532017-06-29T07:22:39Z Finite element analysis of prestressed concrete box girder bridge 2013-08 Othman, Rebaz Abdulghafoor TA Engineering (General). Civil engineering (General) Curved concrete bridge girders have very complex internal forces, stress and strain distribution. As a consequence of their shape, not only the usual bending moments and shear forces are generated, but also important torsion moments are created. These moments rotate the axes of principal tensional stresses and increasing the risk of cracking. A study of torsional moment is found limited in the literature. Post-tensioning can prevent the cracks, but the additional of compression forces in different directions increase the complexity of stress and strain fields sometimes tendons lead to break away the web. Therefore, the curved post-tensioned concrete girders must be particularly designed and carefully constructed. The complete Senai Bridge has been modeled and used for a case study. Trapezoidal section has been chosen in the present investigation. The linear analysis of the box girder has been carry out by using LUSAS software. Three dimensional line modeling have been employed for discretization of domain and to analyze the complex behavior of straight and curved box-girders. Dead Load and Live Load according to British Standard code of practice, for zero torsion as well as maximum torsion are considered. Box section produces higher torsion in curved span compared to straight span with considering the same load. From the analysis result shows that higher thickness of the base and walls leads to increasing the torsional moment. 2013-08 Thesis http://eprints.utm.my/id/eprint/40553/ http://eprints.utm.my/id/eprint/40553/5/RebazAbdulghafoorOthmanMFKA2013.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Civil Engineering Faculty of Civil Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Othman, Rebaz Abdulghafoor
Finite element analysis of prestressed concrete box girder bridge
description Curved concrete bridge girders have very complex internal forces, stress and strain distribution. As a consequence of their shape, not only the usual bending moments and shear forces are generated, but also important torsion moments are created. These moments rotate the axes of principal tensional stresses and increasing the risk of cracking. A study of torsional moment is found limited in the literature. Post-tensioning can prevent the cracks, but the additional of compression forces in different directions increase the complexity of stress and strain fields sometimes tendons lead to break away the web. Therefore, the curved post-tensioned concrete girders must be particularly designed and carefully constructed. The complete Senai Bridge has been modeled and used for a case study. Trapezoidal section has been chosen in the present investigation. The linear analysis of the box girder has been carry out by using LUSAS software. Three dimensional line modeling have been employed for discretization of domain and to analyze the complex behavior of straight and curved box-girders. Dead Load and Live Load according to British Standard code of practice, for zero torsion as well as maximum torsion are considered. Box section produces higher torsion in curved span compared to straight span with considering the same load. From the analysis result shows that higher thickness of the base and walls leads to increasing the torsional moment.
format Thesis
qualification_level Master's degree
author Othman, Rebaz Abdulghafoor
author_facet Othman, Rebaz Abdulghafoor
author_sort Othman, Rebaz Abdulghafoor
title Finite element analysis of prestressed concrete box girder bridge
title_short Finite element analysis of prestressed concrete box girder bridge
title_full Finite element analysis of prestressed concrete box girder bridge
title_fullStr Finite element analysis of prestressed concrete box girder bridge
title_full_unstemmed Finite element analysis of prestressed concrete box girder bridge
title_sort finite element analysis of prestressed concrete box girder bridge
granting_institution Universiti Teknologi Malaysia, Faculty of Civil Engineering
granting_department Faculty of Civil Engineering
publishDate 2013
url http://eprints.utm.my/id/eprint/40553/5/RebazAbdulghafoorOthmanMFKA2013.pdf
_version_ 1747816557416808448