Conductivity measurement 4 cell

Conductivity measurement is one of the most important and widely used to measure the quality of water in all spread of industries, labs & institutions. The Conductivity or specifically electrolytic conductivity is defined as the ability of a substance to conduct electric current. AC current is p...

Full description

Saved in:
Bibliographic Details
Main Author: Kumar, Madanagopal Vijaya
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/5319/1/MadanagopalVijayaKumarMFKE2005.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.5319
record_format uketd_dc
spelling my-utm-ep.53192018-03-07T20:54:54Z Conductivity measurement 4 cell 2005-11 Kumar, Madanagopal Vijaya TK Electrical engineering. Electronics Nuclear engineering Conductivity measurement is one of the most important and widely used to measure the quality of water in all spread of industries, labs & institutions. The Conductivity or specifically electrolytic conductivity is defined as the ability of a substance to conduct electric current. AC current is passed through two plate and voltage are measured across the plates, the resistance is offered by the liquid is measured in terms of voltage using ohms law principle. The conductivity measurement’s heart is the cell, among them 2 cell is most commonly used but it has few problem such as polarization, field effects, less measurement range etc, answer to solve this problem is 4 cell, this cell has 4 cells it can be of different forms – rings, pins, rectangular and square shaped etc. The 4 cell concept helps to totally remove the field effect, polarization problems, cell constant is the key factor, there are different types of cell constant K=0.01, K=0.1, K= 1.0 and K= 10.0. The cell constant is chosen based on the ranges, cell constant 0.01 is used of low conductance measurement such as ultra pure water. As the conductivity goes higher cell constant will also chosen higher. Frequency - lower the conductivity measurement lower is the frequency (32 Hz) as the measurement value goes up the frequency should also go up to get optimum results. The electronics has oscillator which generate required frequency, then high impedance op-amp and frequency dividers are used to measure conductivity. Application of conductivity measurement such as concentration, salinity, resistivity, Total dissolved solids (TDS). All most all industries need this instrument even the drinking water, swimming pool also need this measurement. 2005-11 Thesis http://eprints.utm.my/id/eprint/5319/ http://eprints.utm.my/id/eprint/5319/1/MadanagopalVijayaKumarMFKE2005.pdf application/pdf en public masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Kumar, Madanagopal Vijaya
Conductivity measurement 4 cell
description Conductivity measurement is one of the most important and widely used to measure the quality of water in all spread of industries, labs & institutions. The Conductivity or specifically electrolytic conductivity is defined as the ability of a substance to conduct electric current. AC current is passed through two plate and voltage are measured across the plates, the resistance is offered by the liquid is measured in terms of voltage using ohms law principle. The conductivity measurement’s heart is the cell, among them 2 cell is most commonly used but it has few problem such as polarization, field effects, less measurement range etc, answer to solve this problem is 4 cell, this cell has 4 cells it can be of different forms – rings, pins, rectangular and square shaped etc. The 4 cell concept helps to totally remove the field effect, polarization problems, cell constant is the key factor, there are different types of cell constant K=0.01, K=0.1, K= 1.0 and K= 10.0. The cell constant is chosen based on the ranges, cell constant 0.01 is used of low conductance measurement such as ultra pure water. As the conductivity goes higher cell constant will also chosen higher. Frequency - lower the conductivity measurement lower is the frequency (32 Hz) as the measurement value goes up the frequency should also go up to get optimum results. The electronics has oscillator which generate required frequency, then high impedance op-amp and frequency dividers are used to measure conductivity. Application of conductivity measurement such as concentration, salinity, resistivity, Total dissolved solids (TDS). All most all industries need this instrument even the drinking water, swimming pool also need this measurement.
format Thesis
qualification_level Master's degree
author Kumar, Madanagopal Vijaya
author_facet Kumar, Madanagopal Vijaya
author_sort Kumar, Madanagopal Vijaya
title Conductivity measurement 4 cell
title_short Conductivity measurement 4 cell
title_full Conductivity measurement 4 cell
title_fullStr Conductivity measurement 4 cell
title_full_unstemmed Conductivity measurement 4 cell
title_sort conductivity measurement 4 cell
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2005
url http://eprints.utm.my/id/eprint/5319/1/MadanagopalVijayaKumarMFKE2005.pdf
_version_ 1747814578569347072