High precision technique of measuring the reflectance of reflective materials

A new method of reflectivity measurement is proposed and tested in this Ph.D. study. The method employs fast rotating reference mirror and certain geometry configuration to alternately deliver the light via a sample mirror or by passing it to a photo detector. It has proved to reach a precision of 2...

Full description

Saved in:
Bibliographic Details
Main Author: Lim, Boon Han
Format: Thesis
Language:English
Published: 2001
Subjects:
Online Access:http://eprints.utm.my/id/eprint/6816/1/LimBoonHanPFKE2001.PDF
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.6816
record_format uketd_dc
spelling my-utm-ep.68162018-09-27T04:03:51Z High precision technique of measuring the reflectance of reflective materials 2001-10 Lim, Boon Han TK Electrical engineering. Electronics Nuclear engineering A new method of reflectivity measurement is proposed and tested in this Ph.D. study. The method employs fast rotating reference mirror and certain geometry configuration to alternately deliver the light via a sample mirror or by passing it to a photo detector. It has proved to reach a precision of 2 x lo4 reflectance unit. The precision is at least ten times better than that of conventional reflectometer used in solar energy applications. With good repeatability, the durability test of mirrors is camed out for only one month enabling significant specular reflectance losses of mirrors to be observed instead of more than a year in the conventional case. The reflectometer has provided solutions to few problems that limit the conventional reflectometer. Firstly, the time interval between the collection of reference signal and sample signal is short, therefore, this can reduce the effect due to the changes of environment conditions, particularly, the intensity fluctuation of light source and others. Secondly, by taking advantage of the short measurement time, a large number of readings can be made to suppress the noise level. Thirdly, the value of the reflectance of the reference mirror is not required. In the system, an accurate positioning of laser beam on the photo detector is achieved by a position sensor using a pair of dual cells that acts as an optical lever as well as a position transducer for the feedback system. 2001-10 Thesis http://eprints.utm.my/id/eprint/6816/ http://eprints.utm.my/id/eprint/6816/1/LimBoonHanPFKE2001.PDF application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:62394 phd doctoral Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Lim, Boon Han
High precision technique of measuring the reflectance of reflective materials
description A new method of reflectivity measurement is proposed and tested in this Ph.D. study. The method employs fast rotating reference mirror and certain geometry configuration to alternately deliver the light via a sample mirror or by passing it to a photo detector. It has proved to reach a precision of 2 x lo4 reflectance unit. The precision is at least ten times better than that of conventional reflectometer used in solar energy applications. With good repeatability, the durability test of mirrors is camed out for only one month enabling significant specular reflectance losses of mirrors to be observed instead of more than a year in the conventional case. The reflectometer has provided solutions to few problems that limit the conventional reflectometer. Firstly, the time interval between the collection of reference signal and sample signal is short, therefore, this can reduce the effect due to the changes of environment conditions, particularly, the intensity fluctuation of light source and others. Secondly, by taking advantage of the short measurement time, a large number of readings can be made to suppress the noise level. Thirdly, the value of the reflectance of the reference mirror is not required. In the system, an accurate positioning of laser beam on the photo detector is achieved by a position sensor using a pair of dual cells that acts as an optical lever as well as a position transducer for the feedback system.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Lim, Boon Han
author_facet Lim, Boon Han
author_sort Lim, Boon Han
title High precision technique of measuring the reflectance of reflective materials
title_short High precision technique of measuring the reflectance of reflective materials
title_full High precision technique of measuring the reflectance of reflective materials
title_fullStr High precision technique of measuring the reflectance of reflective materials
title_full_unstemmed High precision technique of measuring the reflectance of reflective materials
title_sort high precision technique of measuring the reflectance of reflective materials
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2001
url http://eprints.utm.my/id/eprint/6816/1/LimBoonHanPFKE2001.PDF
_version_ 1747814692745641984