Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix

The fault monitoring system is a serious part as one of the components that give the negative impact to the system. The fault needs to identify the magnitude of the nominal current, this magnitude is more than five (5) times greater than nominal current. If this happened on the system, it will cause...

Full description

Saved in:
Bibliographic Details
Main Author: Zainal, Mohamad Izwan
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/78264/1/MohamadIzwanZainalMFKE20141.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.78264
record_format uketd_dc
spelling my-utm-ep.782642018-08-03T08:46:49Z Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix 2014-01 Zainal, Mohamad Izwan TK Electrical engineering. Electronics Nuclear engineering The fault monitoring system is a serious part as one of the components that give the negative impact to the system. The fault needs to identify the magnitude of the nominal current, this magnitude is more than five (5) times greater than nominal current. If this happened on the system, it will cause the disaster on the Power System itself, either, system failure or, system damage. The FCL can be applied to the system for maintaining the circuit breaker operates within their limits/ratings. The Y-Bus Matrix has been implemented to analyse the optimal location of FCL for limit the fault current. This Y-Bus Matrix is identify for each buses declared as a Point of Common Coupling. Different location of fault impedance will be resulting the different location of FCL. Two categories of simulation has been used, Matlab Simulation and Y-Bus Matrix Simulation Technique as an additional support instrumentation. This project discover that FCL should be located in series at high admittance value. The analyses are verified by simulation result. 2014-01 Thesis http://eprints.utm.my/id/eprint/78264/ http://eprints.utm.my/id/eprint/78264/1/MohamadIzwanZainalMFKE20141.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:81685 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Zainal, Mohamad Izwan
Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
description The fault monitoring system is a serious part as one of the components that give the negative impact to the system. The fault needs to identify the magnitude of the nominal current, this magnitude is more than five (5) times greater than nominal current. If this happened on the system, it will cause the disaster on the Power System itself, either, system failure or, system damage. The FCL can be applied to the system for maintaining the circuit breaker operates within their limits/ratings. The Y-Bus Matrix has been implemented to analyse the optimal location of FCL for limit the fault current. This Y-Bus Matrix is identify for each buses declared as a Point of Common Coupling. Different location of fault impedance will be resulting the different location of FCL. Two categories of simulation has been used, Matlab Simulation and Y-Bus Matrix Simulation Technique as an additional support instrumentation. This project discover that FCL should be located in series at high admittance value. The analyses are verified by simulation result.
format Thesis
qualification_level Master's degree
author Zainal, Mohamad Izwan
author_facet Zainal, Mohamad Izwan
author_sort Zainal, Mohamad Izwan
title Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_short Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_full Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_fullStr Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_full_unstemmed Optimum location and allocation of fault current limiter in distribution power system using Y-Bus matrix
title_sort optimum location and allocation of fault current limiter in distribution power system using y-bus matrix
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/78264/1/MohamadIzwanZainalMFKE20141.pdf
_version_ 1747817947251867648