Error correction method of wideband multi-port reflectometer using least mean square

The microwave imaging applications have a great demand in recent years by having considerable interest such as in medical, industrial and military aspects. Particularly, in most research of microwave imaging applications, Vector Network Analyzer (VNA) is frequently been used to act as transmitter an...

Full description

Saved in:
Bibliographic Details
Main Author: Che Yob, Rashidah
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utm.my/id/eprint/78350/1/RashidahCheYobMFKE20141.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.78350
record_format uketd_dc
spelling my-utm-ep.783502018-08-26T11:52:01Z Error correction method of wideband multi-port reflectometer using least mean square 2014-01 Che Yob, Rashidah TK Electrical engineering. Electronics Nuclear engineering The microwave imaging applications have a great demand in recent years by having considerable interest such as in medical, industrial and military aspects. Particularly, in most research of microwave imaging applications, Vector Network Analyzer (VNA) is frequently been used to act as transmitter and receiver to allow the measurement of complex ratio between two microwave signals and also provide accurate measurement of reflected and scattering parameters, but it is bulky and expensive. Therefore, in this research, a portable low-cost measurement device namely multi-port reflectometer is proposed as an alternative to VNA in the imaging system. The configuration of this device is formed by four couplers and two power dividers over the operating wideband frequency range between 1 and 6 GHz. The investigation of the characteristics and operation of such reflectometer are accessed via simulation using existing components in Agilent’s Advance Design System (ADS) software and measurement of real components in the laboratory. The real components used are Krytar 90º hybrid coupler and Aeroflex two-way in-phase power divider. Each component constituting the multi-port reflectometer is not operated in error-free state in wideband frequency range. Thus, in order to offer accurate measurement of any Device Under Test (DUT) using wideband multi-port reflectometer, a suitable error correction procedure or known as calibration is implemented. A variety of loads have been used as DUT in order to verify the proposed error correction method. A one-port error model with three standards and Least Mean Square (LMS) technique have been applied to the proposed multi-port reflectometer. Through that, any imperfect operation of the wideband multi-port reflectometer is removed. By implementing the proposed error correction method, the imperfect operation of the multi-port reflectometer has successfully been corrected and an accurate wideband performance with fully error correction can be offered. Therefore, the multi-port reflectometer achieves the desired value of its operation. 2014-01 Thesis http://eprints.utm.my/id/eprint/78350/ http://eprints.utm.my/id/eprint/78350/1/RashidahCheYobMFKE20141.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:80016 masters Universiti Teknologi Malaysia, Faculty of Electrical Engineering Faculty of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Che Yob, Rashidah
Error correction method of wideband multi-port reflectometer using least mean square
description The microwave imaging applications have a great demand in recent years by having considerable interest such as in medical, industrial and military aspects. Particularly, in most research of microwave imaging applications, Vector Network Analyzer (VNA) is frequently been used to act as transmitter and receiver to allow the measurement of complex ratio between two microwave signals and also provide accurate measurement of reflected and scattering parameters, but it is bulky and expensive. Therefore, in this research, a portable low-cost measurement device namely multi-port reflectometer is proposed as an alternative to VNA in the imaging system. The configuration of this device is formed by four couplers and two power dividers over the operating wideband frequency range between 1 and 6 GHz. The investigation of the characteristics and operation of such reflectometer are accessed via simulation using existing components in Agilent’s Advance Design System (ADS) software and measurement of real components in the laboratory. The real components used are Krytar 90º hybrid coupler and Aeroflex two-way in-phase power divider. Each component constituting the multi-port reflectometer is not operated in error-free state in wideband frequency range. Thus, in order to offer accurate measurement of any Device Under Test (DUT) using wideband multi-port reflectometer, a suitable error correction procedure or known as calibration is implemented. A variety of loads have been used as DUT in order to verify the proposed error correction method. A one-port error model with three standards and Least Mean Square (LMS) technique have been applied to the proposed multi-port reflectometer. Through that, any imperfect operation of the wideband multi-port reflectometer is removed. By implementing the proposed error correction method, the imperfect operation of the multi-port reflectometer has successfully been corrected and an accurate wideband performance with fully error correction can be offered. Therefore, the multi-port reflectometer achieves the desired value of its operation.
format Thesis
qualification_level Master's degree
author Che Yob, Rashidah
author_facet Che Yob, Rashidah
author_sort Che Yob, Rashidah
title Error correction method of wideband multi-port reflectometer using least mean square
title_short Error correction method of wideband multi-port reflectometer using least mean square
title_full Error correction method of wideband multi-port reflectometer using least mean square
title_fullStr Error correction method of wideband multi-port reflectometer using least mean square
title_full_unstemmed Error correction method of wideband multi-port reflectometer using least mean square
title_sort error correction method of wideband multi-port reflectometer using least mean square
granting_institution Universiti Teknologi Malaysia, Faculty of Electrical Engineering
granting_department Faculty of Electrical Engineering
publishDate 2014
url http://eprints.utm.my/id/eprint/78350/1/RashidahCheYobMFKE20141.pdf
_version_ 1747817967773548544