Thermal behaviour of mixed blended ashes aerated concrete

This research investigated the used of bottom ash and palm oil fuel ash (POFA) from Tanjung Bin Power Plant and Kahang Palm Oil Mill respectively as sand replacement to produce mixed blended ashes aerated concrete. The goal is to determine characterization and thermal behaviour of the product and to...

Full description

Saved in:
Bibliographic Details
Main Author: Zalani, Rahmah
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://eprints.utm.my/id/eprint/78418/1/RahmahZalaniMSPS2015.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.78418
record_format uketd_dc
spelling my-utm-ep.784182018-08-26T04:56:30Z Thermal behaviour of mixed blended ashes aerated concrete 2015-09 Zalani, Rahmah TA Engineering (General). Civil engineering (General) This research investigated the used of bottom ash and palm oil fuel ash (POFA) from Tanjung Bin Power Plant and Kahang Palm Oil Mill respectively as sand replacement to produce mixed blended ashes aerated concrete. The goal is to determine characterization and thermal behaviour of the product and to compare the best POFA ratio replacement with existing commercial products. POFA was used as sand replacement at 0%, 10%, 20% and 30% by weight with fixed amount of bottom ash. A small-scale wall structure models was developed to study thermal behaviour of product through conduction and convection mechanism heat transfer for seven sunny days at 24-hour. The result showed that thermal conductivity of P30% achieved 0.48 W/mK, 81% lower than conventional concrete. P30% gave the best insulation result among different POFA ratio replacement with 122 minutes in time lag. As for the comparison with commercial aerated concrete, P30% achieved fastest thermal absorption rate with an hour earlier to reach absorption peak and 50% more in thermal mass. This gave better indoor thermal comfort. P30% also exhibited fastest adiabatic state rate with two hour earlier compared to commercial aerated concrete. Good insulation property also gave better result in lessen Urban Heat Island effect at night. However, the stored heat inside the wall contributed towards hotter indoor temperature compared to commercial aerated concrete. Further study in building design alteration might help in mitigating this drawback such as providing better air circulation with cooling chimney and window. 2015-09 Thesis http://eprints.utm.my/id/eprint/78418/ http://eprints.utm.my/id/eprint/78418/1/RahmahZalaniMSPS2015.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:105109 masters Universiti Teknologi Malaysia, School of Graduate Studies School of Graduate Studies
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Zalani, Rahmah
Thermal behaviour of mixed blended ashes aerated concrete
description This research investigated the used of bottom ash and palm oil fuel ash (POFA) from Tanjung Bin Power Plant and Kahang Palm Oil Mill respectively as sand replacement to produce mixed blended ashes aerated concrete. The goal is to determine characterization and thermal behaviour of the product and to compare the best POFA ratio replacement with existing commercial products. POFA was used as sand replacement at 0%, 10%, 20% and 30% by weight with fixed amount of bottom ash. A small-scale wall structure models was developed to study thermal behaviour of product through conduction and convection mechanism heat transfer for seven sunny days at 24-hour. The result showed that thermal conductivity of P30% achieved 0.48 W/mK, 81% lower than conventional concrete. P30% gave the best insulation result among different POFA ratio replacement with 122 minutes in time lag. As for the comparison with commercial aerated concrete, P30% achieved fastest thermal absorption rate with an hour earlier to reach absorption peak and 50% more in thermal mass. This gave better indoor thermal comfort. P30% also exhibited fastest adiabatic state rate with two hour earlier compared to commercial aerated concrete. Good insulation property also gave better result in lessen Urban Heat Island effect at night. However, the stored heat inside the wall contributed towards hotter indoor temperature compared to commercial aerated concrete. Further study in building design alteration might help in mitigating this drawback such as providing better air circulation with cooling chimney and window.
format Thesis
qualification_level Master's degree
author Zalani, Rahmah
author_facet Zalani, Rahmah
author_sort Zalani, Rahmah
title Thermal behaviour of mixed blended ashes aerated concrete
title_short Thermal behaviour of mixed blended ashes aerated concrete
title_full Thermal behaviour of mixed blended ashes aerated concrete
title_fullStr Thermal behaviour of mixed blended ashes aerated concrete
title_full_unstemmed Thermal behaviour of mixed blended ashes aerated concrete
title_sort thermal behaviour of mixed blended ashes aerated concrete
granting_institution Universiti Teknologi Malaysia, School of Graduate Studies
granting_department School of Graduate Studies
publishDate 2015
url http://eprints.utm.my/id/eprint/78418/1/RahmahZalaniMSPS2015.pdf
_version_ 1747817984153354240