Dynamic degradation of porous magnesium under simulated environment of human cancellous bone

Biodegradable metals have been suggested for bone scaffold applications due to their mechanical properties that are better for load bearing applications. Among biodegradable metals, magnesium and its alloy are the most investigated materials due to their mechanical properties which are closer to the...

Full description

Saved in:
Bibliographic Details
Main Author: Md. Saad, Amir Putra
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/79099/1/AmirPutraMdSaadPFKM2017.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.79099
record_format uketd_dc
spelling my-utm-ep.790992018-09-27T06:07:40Z Dynamic degradation of porous magnesium under simulated environment of human cancellous bone 2017 Md. Saad, Amir Putra TJ Mechanical engineering and machinery Biodegradable metals have been suggested for bone scaffold applications due to their mechanical properties that are better for load bearing applications. Among biodegradable metals, magnesium and its alloy are the most investigated materials due to their mechanical properties which are closer to the cancellous bone and could prevent complications such as an aseptic loosening of stress shielding effects, and potentially to be used as bone scaffolds. Bone adapts the mechanical loading from the physiological activities that induced the movement of bone marrow passing through the porous structure of cancellous bone due to the pressure differences. The aim of this research is to analyse the degradation behaviour of porous magnesium under dynamic degradation test for bone scaffold applications. Interconnected holes of porous magnesium have been developed with various percentages of porosity (30%, 41% and 55%) and are fabricated using computer numerical control (CNC) machine. Dynamic immersion test rigs are specifically designed to simulate environment of human cancellous bone. There are two types of tests that have been conducted in this study: (1) fluid flow with different flowrates (0.025, 0.4 and 0.8 ml/min) and (2) fluid flow integrated cyclic loading (different cyclic loading (1000, 2000 and 3500 με) under constant flowrate of 0.025 ml/min). A dynamic immersion test has been conducted for 24, 48 and 72 hours. The results showed that the specimen with a higher percentage of porosity as well as the exposed surface area degrades faster compared to the others. The degradation product formation and clogging pores phenomenon are influenced by the level of flow rates. The effects of different flow rates towards the mechanical integrity of porous magnesium have shown a huge drop of 95% from their original mechanical properties within 3 days, which have deteriorated in both functions; porosity and degradation time. The variation in flowrates used showed that degradation of the material is seven times higher compared to the static immersion test environment. Furthermore, the influenced of integrating fluid flow and cyclic loading have increased the relative weight loss and degradation rate as high as 61.56% and 93.67%, respectively. Additionally, the mechanical properties have improved and increased from 53% to 87% as compared to dynamic immersion test using the mechanical stimulus of fluid flow only. Therefore, the dynamic immersion test with integrated cyclic loading was more reliable and provides realistic environment for degradation assessment compared to static immersion test for bone scaffold application as this study using the boundary of human cancellous bone environment. 2017 Thesis http://eprints.utm.my/id/eprint/79099/ http://eprints.utm.my/id/eprint/79099/1/AmirPutraMdSaadPFKM2017.pdf application/pdf en public phd doctoral Universiti Teknologi Malaysia, Faculty of Mechanical Engineering Faculty of Mechanical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Md. Saad, Amir Putra
Dynamic degradation of porous magnesium under simulated environment of human cancellous bone
description Biodegradable metals have been suggested for bone scaffold applications due to their mechanical properties that are better for load bearing applications. Among biodegradable metals, magnesium and its alloy are the most investigated materials due to their mechanical properties which are closer to the cancellous bone and could prevent complications such as an aseptic loosening of stress shielding effects, and potentially to be used as bone scaffolds. Bone adapts the mechanical loading from the physiological activities that induced the movement of bone marrow passing through the porous structure of cancellous bone due to the pressure differences. The aim of this research is to analyse the degradation behaviour of porous magnesium under dynamic degradation test for bone scaffold applications. Interconnected holes of porous magnesium have been developed with various percentages of porosity (30%, 41% and 55%) and are fabricated using computer numerical control (CNC) machine. Dynamic immersion test rigs are specifically designed to simulate environment of human cancellous bone. There are two types of tests that have been conducted in this study: (1) fluid flow with different flowrates (0.025, 0.4 and 0.8 ml/min) and (2) fluid flow integrated cyclic loading (different cyclic loading (1000, 2000 and 3500 με) under constant flowrate of 0.025 ml/min). A dynamic immersion test has been conducted for 24, 48 and 72 hours. The results showed that the specimen with a higher percentage of porosity as well as the exposed surface area degrades faster compared to the others. The degradation product formation and clogging pores phenomenon are influenced by the level of flow rates. The effects of different flow rates towards the mechanical integrity of porous magnesium have shown a huge drop of 95% from their original mechanical properties within 3 days, which have deteriorated in both functions; porosity and degradation time. The variation in flowrates used showed that degradation of the material is seven times higher compared to the static immersion test environment. Furthermore, the influenced of integrating fluid flow and cyclic loading have increased the relative weight loss and degradation rate as high as 61.56% and 93.67%, respectively. Additionally, the mechanical properties have improved and increased from 53% to 87% as compared to dynamic immersion test using the mechanical stimulus of fluid flow only. Therefore, the dynamic immersion test with integrated cyclic loading was more reliable and provides realistic environment for degradation assessment compared to static immersion test for bone scaffold application as this study using the boundary of human cancellous bone environment.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Md. Saad, Amir Putra
author_facet Md. Saad, Amir Putra
author_sort Md. Saad, Amir Putra
title Dynamic degradation of porous magnesium under simulated environment of human cancellous bone
title_short Dynamic degradation of porous magnesium under simulated environment of human cancellous bone
title_full Dynamic degradation of porous magnesium under simulated environment of human cancellous bone
title_fullStr Dynamic degradation of porous magnesium under simulated environment of human cancellous bone
title_full_unstemmed Dynamic degradation of porous magnesium under simulated environment of human cancellous bone
title_sort dynamic degradation of porous magnesium under simulated environment of human cancellous bone
granting_institution Universiti Teknologi Malaysia, Faculty of Mechanical Engineering
granting_department Faculty of Mechanical Engineering
publishDate 2017
url http://eprints.utm.my/id/eprint/79099/1/AmirPutraMdSaadPFKM2017.pdf
_version_ 1747818146308292608