Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension

This study was performed to determine and evaluate the performance of the graphene-based electromyogram sensor as an alternative to silver/silver chloride (Ag/AgCl) electrode for data acquisition. The main advantage of using graphene electrode is that it is more comfortable for sensitive skin, reusa...

Full description

Saved in:
Bibliographic Details
Main Author: Tan, Jou Pei
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/99574/1/TanJouPeiMSKE2022.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-utm-ep.99574
record_format uketd_dc
spelling my-utm-ep.995742023-03-05T06:55:53Z Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension 2022 Tan, Jou Pei TK Electrical engineering. Electronics Nuclear engineering This study was performed to determine and evaluate the performance of the graphene-based electromyogram sensor as an alternative to silver/silver chloride (Ag/AgCl) electrode for data acquisition. The main advantage of using graphene electrode is that it is more comfortable for sensitive skin, reusable and convenient. An experiment to capture the changes of biceps brachii and triceps brachii during flexion and extension was conducted to test the performance of graphene electrode over Ag/AgCl electrode. The test measurement was carried out using a portable surface electromyography (sEMG). MATLAB software was used to process the acquired signals and analysed its signal-to-noise ratio (SNR) of both electrodes. In addition, SPSS software was used to determine the significant different of both electrodes and to measure the agreement level of both acquired data by using Bland Altman (BA) analysis plot. At 1kg load, graphene electrode’s SNR = 27.081 dB from biceps brachii, SNR = 23.709 dB from triceps brachii. Meanwhile, Ag/AgCl electrode get SNR = 24.932 dB from biceps brachii, SNR = 24.348 dB from triceps brachii. Besides that, it shows agreement of 100 % between both electrode’s performance when using BA analysis. This shows that both electrodes are statistically comparable in terms of SNR, and the graphene electrode are able to perceive 100 % of Ag/AgCl electrode to the standard reading of EMG. The solution presented in this study could be a key factor for continuous innovation to increase user comfort and save earth from electrode waste. 2022 Thesis http://eprints.utm.my/id/eprint/99574/ http://eprints.utm.my/id/eprint/99574/1/TanJouPeiMSKE2022.pdf application/pdf en public http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:149765 masters Universiti Teknologi Malaysia, Faculty of Engineering - School of Electrical Engineering Faculty of Engineering - School of Electrical Engineering
institution Universiti Teknologi Malaysia
collection UTM Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Tan, Jou Pei
Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
description This study was performed to determine and evaluate the performance of the graphene-based electromyogram sensor as an alternative to silver/silver chloride (Ag/AgCl) electrode for data acquisition. The main advantage of using graphene electrode is that it is more comfortable for sensitive skin, reusable and convenient. An experiment to capture the changes of biceps brachii and triceps brachii during flexion and extension was conducted to test the performance of graphene electrode over Ag/AgCl electrode. The test measurement was carried out using a portable surface electromyography (sEMG). MATLAB software was used to process the acquired signals and analysed its signal-to-noise ratio (SNR) of both electrodes. In addition, SPSS software was used to determine the significant different of both electrodes and to measure the agreement level of both acquired data by using Bland Altman (BA) analysis plot. At 1kg load, graphene electrode’s SNR = 27.081 dB from biceps brachii, SNR = 23.709 dB from triceps brachii. Meanwhile, Ag/AgCl electrode get SNR = 24.932 dB from biceps brachii, SNR = 24.348 dB from triceps brachii. Besides that, it shows agreement of 100 % between both electrode’s performance when using BA analysis. This shows that both electrodes are statistically comparable in terms of SNR, and the graphene electrode are able to perceive 100 % of Ag/AgCl electrode to the standard reading of EMG. The solution presented in this study could be a key factor for continuous innovation to increase user comfort and save earth from electrode waste.
format Thesis
qualification_level Master's degree
author Tan, Jou Pei
author_facet Tan, Jou Pei
author_sort Tan, Jou Pei
title Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
title_short Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
title_full Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
title_fullStr Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
title_full_unstemmed Evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
title_sort evaluation of graphene electrode in capturing the changes of muscle activity during flexion and extension
granting_institution Universiti Teknologi Malaysia, Faculty of Engineering - School of Electrical Engineering
granting_department Faculty of Engineering - School of Electrical Engineering
publishDate 2022
url http://eprints.utm.my/id/eprint/99574/1/TanJouPeiMSKE2022.pdf
_version_ 1776100620102533120