Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)

This study aims to develop novel calixarenes monolayer and multilayer films for sensing properties of heavy metals ion, namely Pb2+ and Cd2+, using Langmuir and Langmuir-Blodgett (LB) films techniques. Langmuir monolayer formation at the air-water interface was achieved by spreading amphiphilic mole...

Full description

Saved in:
Bibliographic Details
Main Author: Noor Azyyati Noor Azahari
Format: thesis
Language:eng
Published: 2014
Subjects:
Online Access:https://ir.upsi.edu.my/detailsg.php?det=2413
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:ir.upsi.edu.my:2413
record_format uketd_dc
spelling oai:ir.upsi.edu.my:24132020-02-27 Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR) 2014 Noor Azyyati Noor Azahari QC Physics This study aims to develop novel calixarenes monolayer and multilayer films for sensing properties of heavy metals ion, namely Pb2+ and Cd2+, using Langmuir and Langmuir-Blodgett (LB) films techniques. Langmuir monolayer formation at the air-water interface was achieved by spreading amphiphilic molecules on water subphase and compressing them into an ordered arrangement. LB films were formed by transferring the floating monolayer molecules at the air-water interface onto a solid substrate. The properties of the calixarenes molecules developed from Langmuir film were discussed on terms of surface pressure-area (?-A) isotherms, surface potential (V) and effective dipole moment (?) of the molecules in the absence and presence of metal ions. The calixarenes LB films were characterized by UV-visible spectroscopy to identify their optical properties. FTIR analysis yielded useful information regarding the specific interactions of calixarenes and the tested metal ions. Under the optimum experimental conditions, the lowest detectable concentration of Pb2+ is 2.5x10-2 mM and Cd2+ is 5.0x10-2 mM. Furthermore, calixarenes showed a well-defined response towards the Pb2+ and Cd2+ with good sensitivity and reproducibility. The detection mechanism of calixarenes with Pb2+ and Cd2+ ions in aqueous solution were also discussed. These findings are suitable to be applied for the development of optical sensors for the detection of heavy metal pollution in water 2014 thesis https://ir.upsi.edu.my/detailsg.php?det=2413 https://ir.upsi.edu.my/detailsg.php?det=2413 text eng closedAccess Masters Universiti Pendidikan Sultan Idris Fakulti Sains dan Matematik N/A
institution Universiti Pendidikan Sultan Idris
collection UPSI Digital Repository
language eng
topic QC Physics
spellingShingle QC Physics
Noor Azyyati Noor Azahari
Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)
description This study aims to develop novel calixarenes monolayer and multilayer films for sensing properties of heavy metals ion, namely Pb2+ and Cd2+, using Langmuir and Langmuir-Blodgett (LB) films techniques. Langmuir monolayer formation at the air-water interface was achieved by spreading amphiphilic molecules on water subphase and compressing them into an ordered arrangement. LB films were formed by transferring the floating monolayer molecules at the air-water interface onto a solid substrate. The properties of the calixarenes molecules developed from Langmuir film were discussed on terms of surface pressure-area (?-A) isotherms, surface potential (V) and effective dipole moment (?) of the molecules in the absence and presence of metal ions. The calixarenes LB films were characterized by UV-visible spectroscopy to identify their optical properties. FTIR analysis yielded useful information regarding the specific interactions of calixarenes and the tested metal ions. Under the optimum experimental conditions, the lowest detectable concentration of Pb2+ is 2.5x10-2 mM and Cd2+ is 5.0x10-2 mM. Furthermore, calixarenes showed a well-defined response towards the Pb2+ and Cd2+ with good sensitivity and reproducibility. The detection mechanism of calixarenes with Pb2+ and Cd2+ ions in aqueous solution were also discussed. These findings are suitable to be applied for the development of optical sensors for the detection of heavy metal pollution in water
format thesis
qualification_name
qualification_level Master's degree
author Noor Azyyati Noor Azahari
author_facet Noor Azyyati Noor Azahari
author_sort Noor Azyyati Noor Azahari
title Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)
title_short Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)
title_full Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)
title_fullStr Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)
title_full_unstemmed Fabrication of calixarene films using Langmuir and Langmuir-Blodgett (LB) method for heavy metal ion sensing (IR)
title_sort fabrication of calixarene films using langmuir and langmuir-blodgett (lb) method for heavy metal ion sensing (ir)
granting_institution Universiti Pendidikan Sultan Idris
granting_department Fakulti Sains dan Matematik
publishDate 2014
url https://ir.upsi.edu.my/detailsg.php?det=2413
_version_ 1747833008454369280