Behaviour of cold formed steel under axial compression force

This master project describes a series of compression test performed on lipped channel columns fabricated from cold formed high tensile steel plates with nominal yield stress of 550 MPa. This test includes Lysaght C-section ranging from C10010 to C20024 with restraint length of 800 mm, 1300 mm &...